Autonics LE7M-2 Скачать руководство пользователя страница 12

K-89

Weekly/Yearly Timer

(A) 

Photoelectric 

Sensors

(B) 

Fiber

Optic

Sensors

(C) 

Door/Area

Sensors

(D) 

Proximity

Sensors 

(E) 

Pressure

Sensors 

(F) 

Rotary

Encoders 

(G) 

Connectors/

Sockets 

(H)

Temperature

Controllers

(I)

SSRs / Power

Controllers

(J) 

Counters 

(K) 

Timers

(L) 

Panel

Meters 

(M)

Tacho /

Speed / Pulse

Meters 

(N)

Display

Units

(O)

Sensor

Controllers 

(P)

Switching

Mode Power

Supplies 

(Q)

Stepper Motors 

& Drivers 

& Controllers

(R)

Graphic/

Logic

Panels

(S)

Field

Network

Devices

(T) 

Software

RUN mode

Program 1 Yearly program

record  No.1 [

r01

]

setting check 

Program 1 Yearly program

record  No.1 [

r01

] setting

modify and delete

Program 1 Yearly program

record  No.2 [

r02

] setting

modify and delete

Program 2 Yearly program

record  No.1 [

r01

] setting

modify and delete

Program 1 Yearly program

record  No.2 [

r02

]

setting check 

Program 2 Yearly program

record  No.1 [

r01

]

setting check 

CHECK

CHECK

CHECK

 Yearly program check, modify and delete

YEAR

 turns ON when check, modify or delete yearly 

program.

● If any key is untouched for 60sec, it is returned to RUN 

mode in weekly or yearly program check. 

● In weekly or yearly program check, it controls output 

according to program setting and output is OFF in 

modify  or delete mode.

● When 

MODE

key is pressed in weekly or yearly program 

record modify, delete stand by or delete mode, current 

work is cancelled and it is returned to check mode.

● Weekly or yearly program record modify and delete

(1) Program record modify

① 

When press 

SET

 key over 3sec. in program check, 

EDT

 

flashes in second display part, press 

SET

 key.

② 

It returns to check mode when finish the modify same 

as the above procedure.

(2) Program record delete

① 

When press 

SET

 key over 3sec. in program check, 

EDT

 

flashes in second display part, press   or   key until 

CLR

 flashes in second display part and press 

SET

 key.

② 

Press 

CLR

 key over 3sec. when 

SET

 turns ON in second 

display part, it returns to program check.

RUN mode

Program 1 weekly program 

record No.1 [

r01

]

setting check 

Program 1 weekly program 

record No.1 [

r01

] setting

modify and delete

Program 1 weekly program 

record No.2 [

r02

] setting

modify and delete

Program 2 weekly program 

record No.1 [

r01

] setting

modify and delete

Program 1 weekly program 

record No.2 [

r02

]

setting check 

Program 2 weekly program 

record No.1 [

r01

setting check 

 Program Check, Modify And Delete

Press 

CHECK

 

key for 1sec.

CHECK

CHECK

CHECK

 Weekly program check, modify and delete

Press 

MODE

 key

for 3sec.

Press 

SET

key for 3sec.

Press 

SET

key for 3sec.

Press 

SET

key for 3sec.

Press 

CHECK

 

key for 1sec.

Press 

MODE

 key

for 3sec.

Press 

SET

key for 3sec.

Press 

SET

key for 3sec.

Press 

SET

key for 3sec.

It is able to set year of start/end date in yearly program 

setting up to 2 years later from the present year.

 key is pressed, move the 

flashing to hour position and 

select PM by   or   key 

when ON time is afternoon.

 

ON time setting (AM, PM)

SUN  MON  TUE  WED  THU  FRI  SAT

 

Complete to set

Press 

SET

 key to set ad-

ditional program.

SUN  MON  TUE  WED  THU  FRI  SAT

 

Pulse width setting

Press   or   key 4 times 

to select pulse width as 5s 

and press 

SET

 key.

SUN  MON  TUE  WED  THU  FRI  SAT

 

ON time setting (Hour, Minute)

Press   or   key twice to 

set 10 and press 

SET

 key 

after check 00min.

SUN  MON  TUE  WED  THU  FRI  SAT

Содержание LE7M-2

Страница 1: ...temperature 25 4sec week Temperature error 0 01 0 05sec ratio by set time Memory protection Over 5 years at 25 Control Output Contact type SPDT Single Pole Double Throw Contact capacity 250VAC 10A res...

Страница 2: ...RCE SOURCE Single phase Three phase COM COM COM COM N O N O N O Power of single phase Load Load Magnetic Switch Magnetic Switch Power of three phase N O RETURN INPUT CONTACT OUT 250VAC 10A RESISTIVE L...

Страница 3: ...then rotate it 180 degree Assemble terminal block to case by using the 4 bolts Dimensions Mounting How To Switch From The Flush Mounting To Surface Mounting Type unit mm 68 0 7 0 68 0 7 0 Remove termi...

Страница 4: ...ain display 13 Remaining step display 14 Operation mode display 15 Power restore input display 16 Output mode display 17 Year month date display 18 Unit of pulse width display 19 Sub display 20 CHECK...

Страница 5: ...ower restore input is detected RET IN turns off and output operates according to program Power restore input Input contact signal in external Return input terminals to by switch or relay or press key...

Страница 6: ...matic Daylight Saving Time mode and press key But the minute will be fixed as 00 Normal NOR daylight saving time mode Press key over 3sec in RUN mode 1h turns ON and current time is faster as an hour...

Страница 7: ...flash Program 1 yearly program setting Program 2 yearly program setting All Program 1 weekly program delete All Program 2 weekly program delete All Program 1 yearly program delete All Program 2 yearl...

Страница 8: ...g Press key to move the indicator to monday it will be lighted when or key are pressed and move it to tuesday by key Press SET key after tuesday wednesday thursday friday turn ON SUN MON TUE WED THU F...

Страница 9: ...r 10min OFF for 5min Weekly cycle mode E g Output 1 OUT1 is ON for 10min and OFF for 5min from monday 6 00AM to saturday 5 30PM SUN MON TUE WED THU FRI SAT Advance to program 1 P1 weekly program setti...

Страница 10: ...early holiday setting SUN MON TUE WED THU FRI SAT Press MODE key to finish the additional yearly holiday setting and press SET key to set It is able to set yearly holiday up to 12 times Complete to ye...

Страница 11: ...ion by key SUN MON TUE WED THU FRI SAT OFF time setting Hour Minute Move the flashing to minute position after set 5 00 by or key and set the minute as 10 and press SET key SUN MON TUE WED THU FRI SAT...

Страница 12: ...display part press SET key It returns to check mode when finish the modify same as the above procedure 2 Program record delete When press SET key over 3sec in program check EDT flashes in second disp...