background image

K-95

(A) 

Photo

electric

sensor

(B) 

Fiber

optic

sensor

(C) 

Door/Area

sensor 

(D) 

Proximity

sensor 

(E) 

Pressure

sensor 

(F) 

Rotary

encoder 

(G) 

Connector/

Socket 

(H)

Temp.

controller

(I)

SSR/

Power

controller

(J) 

Counter 

(K) 

Timer 

(L) 

Panel

meter 

(M)

Tacho/

Speed/ Pulse

meter 

(N)

Display

unit

(O)

Sensor

controller 

(P)

Switching

power

supply 

(Q)

Stepping

motor&

Driver&Controller

(R)

Graphic/

Logic

panel

(S)

Field

network

device

(T) 

Software

(U) 

Other

 Complete to yearly holiday

Press 

MODE

 key to 

fi

 nish  the

additional yearly holiday
setting and press 

SET

 key to 

set .

 It is able to set yearly

     holiday up to 12 times.

SUN  MON  TUE  WED  THU  FRI  SAT

 Advance to Program1(P1) yearly program setting mode 

Press 

MODE

 key for 3 sec. in

RUN mode, "

P

fl

 ashes and

press 

MODE

 key once, then,

"

P

"and YEAR 

fl

 ash and

press 

SET

 key to set.

 Mode type setting

Press 

SET

 key when ON/OFF

fl

 ashes.

 Start date setting

Press   key until month
position flashes and set Apr 
by    or  key and press 

 key until date position 

fl

 ashes.  Press 

SET

 key after 

set 5th by   or   key.

 Advance to yearly holiday mode

Press 

MODE

 key over 3sec.

to move to the setting group1 
in RUN mode and press it
repeatedly until "

fl

 ashes

in second display part and
press 

SET

 key.

 Yearly holiday No. display

Press 

SET

 key after check

yearly holiday No.

 Start date of yearly holiday setting

Press    key until month( )
position 

fl

 ashes and set 

May by    or  key and 
p r e s s  

  k e y   u n t i l   d a t e 

position flashes. Press 

SET

 

key after set 5th by    or   
key.

 End date of yearly holiday setting

The 

fl

 ashing is moved to

month( ) position directly 
and press   or  key to set 
May and press   key until 

date position 

fl

 ashes.

Press 

SET

 key after set 5th 

by    or   key.

 Advance to weekly day change mode

Press 

MODE

 key over 3sec.

to move to the setting group1 
in RUN mode and press it 
repeatedly until "

fl

 ashes

in second display part and
press 

SET

 key.

 Standard day selection

Press 

 key to move the

indicator to saturday and 
press 

SET

 key. after select 

saturday as standard day(Sat 
turns ON) by   or   key.

 Change day selection

Press 

 key to move the

indicator to monday and
select monday to change
(Monday turns ON) by   or

 key and repeat the procedure

to select tuesday to change
(Tue turns ON) and press

SET

 key to complete.

 Yearly program setting

 Yearly ON/OFF mode

(Ex) Output(OUT) is ON from every 5, Apr to 7, Apr at
         9:00AM and OFF 5:10PM.

 Program setting

 Yearly holiday mode

It operates to off the output without program adjustment 
during previously set yearly holiday period available from
present year to 31, Dec. of the next year. 
Designate the start date of yearly holiday and year of end 
date as every year("--") to repeat the holiday mode for speci

fi

 ed

in every year.

 Setting example

Set every year 5, May to off the output.

SUN  MON  TUE  WED  THU  FRI  SAT

SUN  MON  TUE  WED  THU  FRI  SAT

SUN  MON  TUE  WED  THU  FRI  SAT

SUN  MON  TUE  WED  THU  FRI  SAT

SUN  MON  TUE  WED  THU  FRI  SAT

SUN  MON  TUE  WED  THU  FRI  SAT

SUN  MON  TUE  WED  THU  FRI  SAT

SUN  MON  TUE  WED  THU  FRI  SAT

SUN  MON  TUE  WED  THU  FRI  SAT

SUN  MON  TUE  WED  THU  FRI  SAT

Weekly/Yearly Timer

Содержание LE365S-41

Страница 1: ...ogram 48 steps for weekly 24 steps for yearly Operation mode ON OFF mode cycle mode pulse mode Temperature error Panel flush surface DIN rail Mounting 15sec month 25 4sec week Time deviation 0 01 0 05...

Страница 2: ...below Front panel mounting Surface mounting type DIN rail type Detach terminal block from case and rotate it 180 degree Detach the terminal block after unscrew terminal screws with tools To raise pan...

Страница 3: ...1 Operation key Press 1h key over 3sec in RUN mode DST mode is set and released 22 SET key 23 Output selection switch AUTO Control output according to the set program ON Output is ON Operation OFF Out...

Страница 4: ...lse ON time to next mode Power restore mode In setting group 2 LEVEL2 turns ON or flashes select Auto or Normal by or key and press SET key to set Auto power restore mode Output operates according to...

Страница 5: ...o or Normal by or key and press SET key to set Auto daylight saving time mode Current time will be faster as an hour when it is started and slower as an hour when it is finished Automatic daylight sav...

Страница 6: ...ET SET SET SET SET SET SET SET SET SET SET SET MODE MODE MODE MODE MODE MODE MODE MODE MODE MODE MODE MODE Setting group 1 Setting group 2 When it is advanced to setting group 1 in RUN mode output wil...

Страница 7: ...y when ON time is afternoon ON time setting Hour Min Set 8 00 by or key and press SET key OFF day setting Press SET key to check ON OFF day ON day setting Press key to move the indicator to Monday it...

Страница 8: ...ete to set Press SET key to set additional program Program setting 6 00 AM Start Cycle mode 5 30 PM ON for 10min OFF for 5min Weekly day change When the specified day mode is required to install in ot...

Страница 9: ...ress SET key after set 5th by or key End date of yearly holiday setting The flashing is moved to month position directly and press or key to set May and press key until date position flashes Press SET...

Страница 10: ...rectly by key and set 4th by or key after move it to date position by key then press SET key ON time setting AM PM key is pressed move the flashing to hour position and select PM by or key when ON tim...

Страница 11: ...rogram check modify and delete Yearly program check modify and delete YEAR turns ON when check modify or delete yearly program If any key is untouched for 60sec it is returned to RUN mode in weekly or...

Отзывы: