Autonics LA8N Series Скачать руководство пользователя страница 2

J-5

(A) 

Photo

electric

sensor

(B) 

Fiber

optic

sensor

(C) 

Door/Area

sensor 

(D) 

Proximity

sensor 

(E) 

Pressure

sensor 

(F) 

Rotary

encoder 

(G) 

Connector/

Socket 

(H)

Temp.

controller

(I)

SSR/

Power

controller

(J) 

Counter 

(K) 

Timer 

(L) 

Panel

meter 

(M)

Tacho/

Speed/ Pulse

meter 

(N)

Display

unit

(O)

Sensor

controller 

(P)

Switching

power

supply 

(Q)

Stepping

motor&

Driver&Controller

(R)

Graphic/

Logic

panel

(S)

Field

network

device

(T) 

Software

(U) 

Other

1: Terminal 2 and 5 are connected inside. (Non-isolated)     

Use reliable contacts enough to flow 5

 current.

Input type

No-backlight

Backlight 

No-voltage

input 

type

●LA8N-BN

1

●LA8N-BN-L

Terminal (1, 2, 3) and (4, 5) are insulated inside.

Voltage

input 

type

●LA8N-BV

1

●LA8N-BV-L

Free voltage

input type

●LA8N-BF

Terminal (1, 2) and (4, 5) are insulated inside.

-

1

2

3

4

5

SIGNAL

INPUT

RESET

UP/DOWN

1

2

3

4

5

RESET

+  -

24VDC

BACKLIGHT

SIGNAL

INPUT

+  -

1

2

3

4

5

4.5-30VDC

SIGNAL

INPUT

RESET

UP/DOWN

+  

-

+  

-

1

2

3

4

5

SIGNAL

INPUT

RESET

4.5-30VDC

24VDC

BACKLIGHT

1

2

3

4

5

6-240VDC

SIGNAL INPUT

RESET

24-240VAC 50/60Hz

+  -

~

!

!

Compact LCD Counter

 

Connections

● Bracket

● Panel cut-out

48

24

36

M

in

. 3

7

Min. 55

45

+0.6

  0

22.2

+0.3

  0

22

54

4

 Dimensions

(unit: mm)

● Solid-state input

● Contact input

※ 

When power is applied to terminal No   and  , input terminal

circuit can be broken and a malfunction can occur.

(NPN output, PNP output, PNP open collector output type

 sensor cannot be used.)

※ 

 and   are connected inside.

※ 

Please use reliable contacts enough to flow

     3VDC 5

 of current.

 Input connections

 No-voltage input (Standard sensor: NPN open collector output type sensor)

SIG. INPUT

RESET

3V

1.2

1.2

560

0V

[Counter]

M

ai

ci

rc

ui

t

SIG.

INPUT

RESET

+V

12-24VDC

+
-

3V

1.2

1.2

560

OUT

0V

[Counter]

[Sensor]

M

ai

ci

rc

ui

t

 

For backlight function model, the input terminals are no.  ,   and the GND terminal is no.   . 

Содержание LA8N Series

Страница 1: ... 0 2VAC 0 2 4VDC RESET input No voltage input Voltage input No voltage input Min signal width UP DOWN RESET input Min 20ms RESET input Min 20ms UP DOWN RESET input Min 20ms RESET input Min 20ms RESET input Min 20ms Max counting speed 1cps 30cps 1kcps 20cps External set switch SW1 1 SW2 2 SW3 3 SW1 1 SW3 3 Insulation resistance Min 100MΩ at 500VDC megger Dielectric strength 4 2 000VAC 60Hz for 1min...

Страница 2: ...INPUT RESET UP DOWN 1 2 3 4 5 RESET 24VDC BACKLIGHT SIGNAL INPUT 1 2 3 4 5 4 5 30VDC SIGNAL INPUT RESET UP DOWN 1 2 3 4 5 SIGNAL INPUT RESET 4 5 30VDC 24VDC BACKLIGHT 1 2 3 4 5 6 240VDC SIGNAL INPUT RESET 24 240VAC 50 60Hz Compact LCD Counter Connections Bracket Panel cut out 48 24 36 Min 37 Min 55 45 0 6 0 22 2 0 3 0 22 54 4 Dimensions unit mm Solid state input Contact input When power is applied...

Страница 3: ... 240VDC 24 240VAC Main circuit Set switch 1 Front panel Enable Disable 2 Front panel 1cps 30cps 1kcps SW1 1 Switch SW1 is a switch to Enable Disable the front panel RESET key Factory default Enable SW2 2 Switch SW2 is a switch for setting max counting speed Factory default 1cps Free voltage input type 20cps is fixed 1 2 3V 560 4 5 30VDC SIG INPUT RESET V 12 24VDC OUT 0V Sensor 20 4 7 Counter Main ...

Страница 4: ...0 1 2 1 0 1 2 1 0 1 L H L H SIGNAL INPUT UP DOWN Counting value Voltage input No voltage input Free voltage input H 4 5 30VDC Short 24 240VAC 6 240VDC L 0 2VDC Open 0 2VAC 0 2 4VDC Change SW3 setting after removing the case Supply RESET signal front panel or terminal RESET after setting SW2 SW3 during operation SW3 is a switch for decimal point position Factory default No decimal point LITHUM BA 3...

Отзывы: