LCD Timer

 SW3 setting

SW3 is a switch for setting time sepcification. TS1, TS2, TS3(

※Factory default: TS1)

Battery

holder

direction

TS1  TS2  TS3

       +

LITHUM BA

       3V

<Set TS1>

TS1 TS2 TS3

<Set TS2>

TS1 TS2 TS3

<Set TS3>

TS1 TS2 TS3

<Time range>

1

TS1

TS2

TS3

hour  min.

99999(59

sec.

99999999

hour

99999(9;

hour   min.

9999(5(9

day  hour

9999D2#9

hour  min.

99999;59

hour min. sec.

999(5(59

day hour min.

999(2#59

hour   min.

9999;5(9

1: Time range is set as SW2, SW3 combination. 

 Set switch 

1

Front panel

Enable

Disable

2

Front panel

 SW1( 

1

 switch )

SW1 is a switch to Enable/Disable the 

front panel RESET key.

Factory default: Enable

 SW2( 

2

 switch )

SW2 is a switch for setting time range.

Factory default: 

999(5(59

(h.m.s)

1

2

Refer to "

<Time range>

" table of 

SW3

 for 

 descriptions.   

 Case detachment and battery replacement

● 

Case detachment

● Battery replacement

Hold up Lock part toward 

①, ②

 

of the product with the 

tool and pull toward 

 to detach the case.

 

When using the tools, be careful not to be wounded.

1. Detach the case.

2. Push the battery and detach it toward 

.

3. Insert a new battery with correct alignment of polarity 

pushing it toward opposite of 

.

※The 

battery is sold separately. Please replace a battery 

by yourself.

Do not burn up or disassemble the lithium battery.

Содержание LA8N-BF

Страница 1: ...VDC megger Dielectric strength 4 2 000VAC 60Hz for 1minute Vibration Mechanical 0 75mm amplitude at frequency of 10 to 55Hz for 1 min in each of X Y Z directions for 1 hour Malfunction 0 3mm amplitude at frequency of 10 to 55Hz for 1 min in each of X Y Z directions for 10 minutes Shock Mechanical 300m s2 approx 30G in each of X Y Z directions for 3 times Malfunction 100m s2 approx 10G in each of X...

Страница 2: ...de Use reliable contacts enough to flow 5 current Input type No backlight Backlight function No voltage input type 1 2 3 4 5 SIGNAL INPUT RESET 1 2 3 4 5 RESET 24VDC BACKLIGHT SIGNAL INPUT Voltage input type 1 2 3 4 5 4 5 30VDC SIGNAL INPUT RESET UP DOWN 1 2 3 4 5 SIGNAL INPUT RESET 4 5 30VDC 24VDC BACKLIGHT Free voltage input type 1 2 3 4 5 6 240VDC SIGNAL INPUT RESET 24 240VAC 50 60Hz Connection...

Страница 3: ... 1 RESET AC type proximity 2 3 4 5 100 240VAC Example of wrong connection Example of correct connection SIGNAL INPUT RESET 1 2 3 4 5 100 240VAC Fig 2 Relay AC type proximity Input from AC type proximity sensor In case of free voltage input type do not connect AC proximity sensors instead of a switch as shown in the figure 1 It may cause malfunction due to sensor s leakage current Connect a relay a...

Страница 4: ...hour 9999D2 9 hour min 99999 59 hour min sec 999 5 59 day hour min 999 2 59 hour min 9999 5 9 1 Time range is set as SW2 SW3 combination Set switch 1 Front panel Enable Disable 2 Front panel SW1 1 switch SW1 is a switch to Enable Disable the front panel RESET key Factory default Enable SW2 2 switch SW2 is a switch for setting time range Factory default 999 5 59 h m s 1 2 Refer to Time range table ...

Отзывы: