Autonics KT-502H Скачать руководство пользователя страница 1

KT-502H

G-2

•  HART protocol
•  330° rotatable display for environment conditions
•  DC4-20mA analog output (2-wire)
•  Various input  (order 1 input type among 22 types)
  RTD: 8 types, Thermocouple: 8 types, 

mV: 4 types, Ω: 2 types

•  Backlight helps to read easily in the darkness
•  Explosion class: Ex d IIC T6
•  Protection structure: IP67 (IEC standard)

502H

0

KT

Model

KT-502H

Power supply

10.5-45VDC (with backlight LCD)

Display method

PV display part: 7-segment 5-digit (character size: W4×H8mm),

Parameter display part: 14-segment 8-digit (character size: W2.6×H4.8mm),

52-bar meter

Display range

-19999 to 99999

Setting method

HART-protocol (no setting key)

Response time

1 sec

Input type

RTD

DPt100Ω, DPt500Ω, DPt1000Ω, Ni100Ω, Ni500Ω, Ni1000Ω, Cu50Ω, Cu100Ω

Thermocouple

K, J, T, E, N, S, B, R

Resistance transmission (Ω) 0 - 400Ω, 0 - 2000Ω

Voltage  transmission (mV)

 10 - 75mV,   100 - 100mV,   100 - 500mV,   100 - 2000mV

Output

DC4-20mA (2-wire)

Accuracy

±0.3%

Alarm

Below 3.8mA, Over 20.5mA/Sensor break 3.6mA

Load

Max.(V power supply - 7.5V)/0.22A

Galvanic insulation

2kVAC(input/output)

Environ- 

ment

Ambient temperature

-20 to 70

, storage: 20 to 80

Ambient humidity

0 to 85%RH, storage: 0 to 85%RH

Explosion class

Ex d IIC T6

Protection structure

IP67 (IEC standard)

Material

Body: Aluminum 

(AlDc.8S), Cover O-Ring: Buna N

Weight

※1

Approx. 1.4kg (approx. 1.2kg)

Features

Please read “Caution for your safety” in operation manual 

before using this unit. 

Ordering Information

Specifications

※1: The weight includes packaging. The weight in paranthesis is for unit only.

Environment resistance is rated at no freezing or condensation.

Item

Description

Mounting bracket

0

Without bracket

1

With bracket

②User temperature range

 1: To order this unit, write the temperature sensor type and the temperature range.

(-270 to 1372, K)

1

Hart Field Communications Protocol may depend on several factors, 

including calibrators, software, or firmware updates.

Содержание KT-502H

Страница 1: ...100 100mV 100 500mV 100 2000mV Output DC4 20mA 2 wire Accuracy 0 3 Alarm Below 3 8mA Over 20 5mA Sensor break 3 6mA Load Max V power supply 7 5V 0 22A Galvanic insulation 2kVAC input output Environ ment Ambient temperature 20 to 70 storage 20 to 80 Ambient humidity 0 to 85 RH storage 0 to 85 RH Explosion class Ex d IIC T6 Protection structure IP67 IEC standard Material Body Aluminum AlDc 8S Cover ...

Страница 2: ... Ω 0 to400Ω 0 to2000Ω Thermocouple B PtRh30 PtRh6 0 to 1820 32 to 3308 E NiCr CuNi 270 to 1000 454 to 1832 J Fe CuNi 210 to 1200 346 to 2192 K NiCr Ni 270 to 1372 454 to 2501 6 N NiCrSi NiSi 270 to 1300 454 to 2372 R PtRh13 Pt 50 to 1768 58 to 3214 4 S PtRh10 Pt 50 to 1768 58 to 3214 4 T Cu CuNi 270 to 400 454 to 752 Analog Voltage 10 75mV 100 100mV 100 500mV 100 2000mV Opening cover Dimensions Co...

Страница 3: ...o 4 PV LRV 5 URV 1 Process Variables 2 Diag Service 3 Basic Setup 4 Detailed Setup 5 Review 1 Test device 2 Loop test 3 Calibration 4 D A trim Connect reference meter ABORT O K Fid dev output 4 000 mA equal to reference meter 1 Yes 2 No ABORT ENTER Enter meter Value 4 000 HELP DEL ABORT ENTER Setting fid dev output to 4mA ABORT O K WARN Loop should be removed from automatic control ABORT O K Selec...

Страница 4: ...supply or cut off the power Switch or circuit breaker should be installed nearby users for convenient control Do not use this unit near the high frequency instruments high frequency welding machine sewing machine large capacity SCR controller Installation environment Indoor Outdoor Altitude max 2 000m Pollution degree 2 Installation category Ⅱ Use the verified explosion proof electric connection c...

Отзывы: