U-4

KRN1000 Series

-|Transparent setting guide|-

 

5.6-inch color TFT LCD (640×480) touchscreen display with 

excellent readability and intuitive control interface

 

Supports 27 input types (thermocouple, RTD, analog voltage 

and current[shunt])

 

4 / 8 / 12 / 16 input channel models available

 

Various communication methods (RS422/485, Ethernet, USB) 

standard

 

25 to 250 ms high-speed sampling, 1 to 3600 s recording cycle

 

200 MB internal memory and external memory support  

(SD/USB up to 32 GB)

 

Store and backup internal data to external memory (SD/USB)

 

9 different graph types available

 

Various option input/output available: digital input  

(contact/non-contact), alarm output, transmitter power output

 

Compact, space-saving design (rear length: 69.2 mm)

 

For more information and instructions, refer to the user manual and the user manual for communication. 

Visit our website (www.autonics.com) to download the manuals.

 

The user manual includes product specifications, functions, and operations.

 

The user manual for communication includes information about Modbus RTU protocol, Modbus TCP protocol, and 

Modbus mapping table. 

LCD Touchscreen Paperless Recorder

 Features

 Manuals

 Comprehensive Device Management Program (DAQMaster)

● DAQMaster is comprehensive device management program for convenient management of parameters and multiple 

device data monitoring.

● Visit our website (www.autonics.com) to download user manual and comprehensive device management program.

Item

Minimum requirements

System

IBM PC compatible computer with Intel Pentium 

 or above

Operations

Microsoft Windows 98/NT/XP/Vista/7/8/10

Memory

256MB+

Hard disk

1GB+ of available hard disk space

VGA

Resolution: 1024×768 or higher

Others

RS-232 serial port (9-pin), USB port

< Computer specification for using software >

< DAQMaster screen >

Please read “Safety Considerations” 

in the instruction manual before using.

Содержание KRN1000 Series

Страница 1: ...unication Visit our website www autonics com to download the manuals The user manual includes product specifications functions and operations The user manual for communication includes information about Modbus RTU protocol Modbus TCP protocol and Modbus mapping table LCD Touchscreen Paperless Recorder Features Manuals Comprehensive Device Management Program DAQMaster DAQMaster is comprehensive dev...

Страница 2: ...mpling period 1 to 4 CH 25ms 125ms 250ms 5 to 16 CH 125ms 250ms internal sampling period is average movement filter and alarm output operation unit time Recording period 1 to 3600 sec Internal memory Approx 200MB External memory 2 SD USB memory max 32GB Dielectric strength 2300VAC 50 60Hz for 1 min between power terminals and case Except Ethernet and USB device Vibration Mechanical 10 to 60Hz 4 9m...

Страница 3: ...ed at the same time If sensor input line is longer it is recommended to use shield cable to reduce noise Type Input Output type Description Universal input Input type RTD JPt100Ω DPt100Ω DPt50Ω Cu100Ω Cu50Ω supplied current approx 190µA Thermocouple B C W5 E G J K L L Russia N P R S T U Analog Voltage 60mV 200mV 2V 1 5V 5V 1V 10V Current 0 20mA 4 20mA measurable when using 250Ω shunt resistance 1 ...

Страница 4: ...0 0 32 0 to 1112 0 273 2 to 873 2 U CC TC U 200 0 to 400 0 328 0 to 752 0 73 2 to 673 2 Platinel Ⅱ TC P 0 0 to 1350 0 32 0 to 2462 0 273 2 to 1623 2 RTD Cu50Ω CU50 200 0 to 200 0 328 0 to 392 0 73 2 to 473 2 Cu100Ω CU100 200 0 to 200 0 328 0 to 392 0 73 2 to 473 2 JPt100Ω JPT100 200 0 to 600 0 328 0 to 1112 0 73 2 to 873 2 DPt50Ω DPT50 200 0 to 600 0 328 0 to 1112 0 73 2 to 873 2 DPt100Ω DPT100 20...

Страница 5: ...nput output Power input Power connection 100 240VAC 50 60Hz Universal input Communication output Option input output 1 Option input output 2 Alarm output 8 channels Alarm output 6 channels Digital input 2 channels Option input output 3 Option input output 4 Alarm output 6 channels Power for transmitter output Alarm output 4 channels Digital input 2 channels Power for transmitter output In case of ...

Страница 6: ...digital figures Front cover Open the front cover There are power switch and USB Host Device SD card slot Power switch Turn ON OFF the power of KRN1000 USB host port Connect the USB memory It recognizes up to 32GB When using extension cable cable length should be up to 1 5m Connect only USB device USB device port Used for connecting PC via Modbus RTU communication SD card slot SD card memory slot I...

Страница 7: ...t value display part Displays the measured value of each channel as graph Set one graph among 9 graphs bar graph Vertical Horizontal Trend graph Vertical Horizontal Mixed graph Divided Vertical Horizontal Trend Graph Group All Digital Bar graph Vertical Horizontal Trend graph Divided Vertical Horizontal Trend Graph Vertical Horizontal Mixed graph Group All Digital Screen Description ...

Страница 8: ...U 11 LCD Touchscreen Paperless Recorder Transparent setting guide Touch the status display part at the upper screen and menu appears as right screen Menu is as below Menu ...

Страница 9: ... limit scale 1000 high limit scale 1000 if input value is 2V display value is 400 In case voltage current shunt input type this mode is used when input value is calculated by Root for the desired display value Differential pressure signal of differential pressure flow meter is calculated Root for the to be measured flux This function is used to measure flux by input value E g In case low limit inp...

Страница 10: ...Set the summer time duration Set enable to summer time and designate start date and end date of summer time at Menu System Info Date Time High Low Limit Graph Scale Value In case of temperature sensor input thermocouple RTD set the graph scale value to set the desired record range Therefore it helps to record as curve at the desired range Display Scale For analog input this function is to set 9999...

Страница 11: ...network hub HUB and gateway etc there is no distance limit but it is recommended to use min network Please use communication cables which is satisfied the below conditions RS422 485 communication Shield Twist Pair over AWG24 characteristic impedance 100Ω capacity component 50 pF m cable length max 1km Ethernet communication Over CAT5E cable max length 100m USB communication Single cable built in f...

Страница 12: ... When input type is temperature sensor Thermocouple RTD and input is break it flashes BURN It is cleared when input is connected ASKey When forgetting and entering invalid password 3 times ASKey appears with error message Contact our service center with ASKey Functions Factory Default Display Menu Default History Mode Graph H Trend Memory Internal Memory File Name Parameter Default Parameter Defau...

Страница 13: ...0 Internal Memory Storage Options Overwrite System Info Parameter Default Parameter Default Date Setting Auto set Summer Time Disable Time Setting Summer Time Duration 1month 1day to 1month 1day Date Type yyyy mm dd Time 1 hour Parameter Default Parameter Default Reservation Recording Date Reservation Type Disable Reservation Recording Time Parameter Default Parameter Default Device Name KRN1000 R...

Страница 14: ...same thickness and length For thermocouple CT temperature sensor use the designated compensation wire for extending wire Keep away from high voltage lines or power lines to prevent inductive noise In case installing power line and input signal line closely use line filter or varistor at power line and shielded wire at input signal line Do not use near the equipment which generates strong magnetic ...

Отзывы: