Autonics KPN Series Скачать руководство пользователя страница 4

User Manual Guide 

 

 

 

© Copyright Reserved Autonics Co., Ltd. 

User Manual Guide 

Please familiarize yourself with the information in this manual before using the product. 

 

This manual provides detailed information on the product's features. It does not offer 

any guarantee concerning matters beyond the scope of this manual. 

 

This manual may not be edited or reproduced in either part or whole without 
permission. 

 

A user manual is not provided as part of the product package. 
Visit our web site (www.autonics.com) to download a copy. 

 

The manual's content may vary depending on changes to the product's software and 
other unforeseen developments within Autonics, and is subject to change without 
prior notice. Upgrade notice is provided through out homepage. 

 

We contrived to describe this manual more easily and correctly. However, if there are 
any corrections or questions, please notify us these on our homepage. 

 

 

Содержание KPN Series

Страница 1: ...re Controllers KPN Series ACM E 0301 AB Thank you for purchasing an Autonics product This user manual contains information about the product and its proper use and should be kept in a place where it w...

Страница 2: ...Preface 2 Copyright Reserved Autonics Co Ltd...

Страница 3: ...ng Autonics product Please familiarize yourself with the information contained in the Safety Precautions section before using this product This user manual contains information about the product and i...

Страница 4: ...r reproduced in either part or whole without permission A user manual is not provided as part of the product package Visit our web site www autonics com to download a copy The manual s content may var...

Страница 5: ...Communication protocol Copyright Reserved Autonics Co Ltd 5 Communication protocol KPN Series is supported to Modbus RTU protocol However it does not support broadcast commands...

Страница 6: ...Communication protocol 6 Copyright Reserved Autonics Co Ltd...

Страница 7: ...10H 14 1 7 Exception Response Error Code 15 2 Modbus Mapping Table 17 2 1 Read Coils Func01 Write Single Coil Func05 17 2 2 Read Discrete Inputs Func02 17 2 3 Read Input Registers Func04 18 2 4 Read H...

Страница 8: ...Table of Contents 8 Copyright Reserved Autonics Co Ltd...

Страница 9: ...1Byte 1Byte 1Byte 1Byte 1Byte If read the output status ON 1 OFF 0 of 10EA within coil 000001 0000 H to 000010 0009 H on Slave side Address 17 from Master side Query Master Slave Address Function Star...

Страница 10: ...yte 1Byte 1Byte 1Byte If read the input status ON 1 OFF 0 of 10EA range 100001 0000 H to 100010 0009 H in the Slave side Address 17 from the Master side Query Master Slave Address Function Starting Ad...

Страница 11: ...igh Low High Low High Low Low High 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte If read the values of 2EA from Holding Register 400001 0000 H to 400002 0001 H in Slave Address 17...

Страница 12: ...CRC16 Low High 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte If read the values of 2EA range from Input Register 300001 0000 H to 300002 0001 H on Slave side Address 17 from Master side Query Master...

Страница 13: ...sponse Slave Slave Address Function Register Address Preset Data Error Check CRC16 High Low High Low Low High 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte If write 10 A H to Holding Register 400001...

Страница 14: ...in common to the range of Holding Register 400001 0000 H to 400002 0001 H on Slave side Address 17 from Master side Query Master Slave Address Function Starting Address No of Register Byte Count Data...

Страница 15: ...data is inconsistent with transmittable address from the device ILLRGAL DATA VALUE Exception Code 03 H The number of queried data are inconsistent with the numbers of transmittable transferable data f...

Страница 16: ...1 Modbus RTU protocol 16 Copyright Reserved Autonics Co Ltd...

Страница 17: ...100003 0002 lamp 0 OFF 1 ON 100004 0003 OUT1 lamp Control output1 display lamp 0 OFF 1 ON 100005 0004 OUT2 lamp Control output2 display lamp 0 OFF 1 ON 100006 0005 AT lamp Auto tuning RUNlamp 0 OFF 1...

Страница 18: ...eserved 300117 0074 Reserved 300118 0075 Coil status start Address 0000 300119 0076 Coli status Quantity 0 300120 0077 Input status start Address 0000 300121 0078 Input status Quantity 0 300122 0079 H...

Страница 19: ...splay lamp 0 OFF 1 ON Bit A AL3 lamp Alarm output3 display lamp 0 OFF 1 ON Bit B MAN lamp Manual control display lamp 0 OFF 1 ON Bit C DI 1 input DI 1 input status 0 OFF 1 ON Bit D DI 2 input DI 2 inp...

Страница 20: ...ss Parameter Description Set range Unit Factory default 400051 0032 R S Control output RUN STOP 0 RUN 1 STOP RUN 400052 0033 SV N Multi SV No 0 SV 0 1 SV 1 2 SV 2 3 SV 3 SV 0 400053 0034 CT A Heater c...

Страница 21: ...0 05 0 400110 006D hHYS Heating hysteresis 1 to 100 001 to 100 temperature H analog 1 to 1000 00 1 to 10 0 temperature L Digit 002 400111 006E hOST Heating OFF offset 0 to 100 000 to 100 temperature...

Страница 22: ...MAvF Input digital filter 1 to 1200 00 1 to 12 0 sec 00 1 400161 00A0 L SV SV low limit set value Input low limit value L SC to H SV 1Digit F S 200 00 0 400162 00A1 H SV SV high limit set value L SV...

Страница 23: ...0 0000 to 3600 sec 0000 400212 00D3 A OF Alarm output2 OFF delay time 0 to 3600 0000 to 3600 sec 0000 400213 00D4 AL 3 Alarm output3 mode 0 OFF 1 DVCC 2 DV 3 DVC 4 CDV 5 PVCC 6 PV 7 LBA 8 SBA 9 HBA LB...

Страница 24: ...100 to 5 000 100 to 000 1 000 400258 0101 BAR Bar graph 0 OFF 1 OUT1 standard 0 OFF 1 OUT1 2 OUT2 3 ALL heating cooling OUT1 400259 0102 Manual control initial MV 0 AUTO 1 PrMV ALL 400260 0103 ItMV Ma...

Страница 25: ...2 Modbus Mapping Table Copyright Reserved Autonics Co Ltd 25...

Страница 26: ...Dimensions or specifications on this manual are subject to change and some models may be discontinued without notice...