background image

J-43

(A) 

Photo

electric

sensor

(B) 

Fiber

optic

sensor

(C) 

Door/Area

sensor 

(D) 

Proximity

sensor 

(E) 

Pressure

sensor 

(F) 

Rotary

encoder 

(G) 

Connector/

Socket 

(H)

Temp.

controller

(I)

SSR/

Power

controller

(J) 

Counter 

(K) 

Timer 

(L) 

Panel

meter 

(M)

Tacho/

Speed/ Pulse

meter 

(N)

Display

unit

(O)

Sensor

controller 

(P)

Switching

power

supply 

(Q)

Stepping

motor&

Driver&Controller

(R)

Graphic/

Logic

panel

(S)

Field

network

device

(T) 

Software

(U) 

Other

Up/Down Counter/Timer

1

1

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

12

2

2

-

-

+

+

48

CP1

CP1

CP2

CP2

1

1

2

2

RESET

RESET

SOURCE

SOURCE

100-240VAC 50/60Hz,

12-24VAC/DC

100-240VAC 50/60Hz,

12-24VAC/DC

(I12VDC

(50

mA

)

(I12VDC

(50

mA

)

0V

0V

CONTACT OUT:

250VAC 3A

RESISTIVE LOAD

11

91

44.8

Min. 65

61

Min. 55

※ 

1

. Connection of PNP input

※ 

2

. Connection of NPN input

※ 

CP2(INHIBIT): Time Hold terminal

     when using for timer.

※ 

Operated by a power ON start

     when it is used as a timer.

Sensor

Sensor

Sensor

Sensor

FXS Sereis

FXS Sereis

FXS Sereis

FXS Sereis

FXS Sereis

FXS Sereis

(NPN output)

(PNP output)

(NPN open

collector output)

(PNP open

collector output)

 CP1, CP2(INHIBIT), RESET input

※ 

CP1, CP2(INHIBIT), RESET input

※ 

Please select the counting

     speed as 30cps when it is
     used for counter.

※ 

Please select the counting

     speed as 30cps when it is

     used for counter.

Brown

Brown

Brown

Brown

Black

Black

Black

Black

Blue

Blue

Blue

Blue

0V

0V

0V

0V

0V

0V

+12V

+12V

+12V

+12V

+12V

+12V

5.4

5.4

5.4

5.4

5.4

5.4

Inner

circuit

Inner

circuit

Inner

circuit

Inner

circuit

Inner

circuit

Inner

circuit

RL

10

RL

10

 Connections

 Dimensions

 Input connections

 Solid-state input(Standard sensor : NPN output type sensor)

 Bracket

 Panel cut-out

 Solid-state input(Standard sensor : PNP output type sensor)

 Contact input

 Contact input

 Input logic : No-voltage(NPN) input

 Input logic : Voltage(PNP) input

 FX4S

 FX5S-I

45

+0.6

  0

45

+0.6
  0

(unit: mm)

Содержание FX4S

Страница 1: ...Control output Contact Type SPDT 1c Capacity 250VAC 3A at resistive load Solid state Type NPN open collector Capacity 30VDC Max 100mA Max Memory protection 10 years When using non volatile semiconductor memory External power 12VDC 10 50mA Max Insulation resistance Min 100MΩ at 500VDC megger Dielectric strength 2000VAC 50 60Hz for 1 minute Noise strength AC power 2kV the square wave noise pulse wid...

Страница 2: ...when using for timer Operated by a power ON start when it is used as a timer Sensor Sensor Sensor Sensor FXS Sereis FXS Sereis FXS Sereis FXS Sereis FXS Sereis FXS Sereis NPN output PNP output NPN open collector output PNP open collector output CP1 CP2 INHIBIT RESET input CP1 CP2 INHIBIT RESET input Please select the counting speed as 30cps when it is used for counter Please select the counting sp...

Страница 3: ... logic Select PNP Voltage input In case of operating the load by power supply of the sensor Using 2 counters with one sensor It is available to use 2 counters with one sensor Please connect as the power of sensor is supplied from only one of countes and design input logic with same way Please select proper capacity of load because total current consumption should not be exceed current capacity Max...

Страница 4: ...t operation mode in indication type FX5S I and SW2 selection switch SW1 CP1 CP2 1cps 30cps 2kcps 5kcps SW1 Function 4 Down mode Up mode SW1 Function 5 Counter Timer SW1 Function 8 Disable the memory protection Enable the memory protection ON OFF ON OFF ON OFF ON OFF 6 7 ON OFF 6 7 ON OFF 6 7 ON OFF 6 7 ON OFF ON OFF ON OFF Max counting speed ON ON OFF 3 2 1 8 7 6 5 4 3 2 1 SW2 SW1 Setting function...

Страница 5: ...0 0 n 1 n 1 n 1 n 1 n 1 n 1 n 1 n 1 n 1 n n n n n n 2 n 2 n 2 n 2 n 2 n 2 n 2 n 2 n 2 n 2 n 2 n 3 n 3 n 3 n 3 n 3 n 4 n 4 n 5 n 5 n 3 n 3 n 3 0 0 0 0 0 1 1 1 1 1 1 1 2 2 2 2 3 3 No counting No counting No counting No counting 4 4 5 5 2 2 2 2 3 3 3 3 Ⓐ Ⓐ Ⓐ Ⓐ Ⓐ Ⓐ Ⓐ Ⓐ Ⓐ Ⓐ ⒷⒷⒷⒷ ⒷⒷⒷⒷ L L L L L L L L L L L L L L L L L L Count value Count value Count value Count value Count value Count value Count value ...

Страница 6: ... 99min 59 9sec 999 9min 9999 9min 99hour 59min 9hour 59min 59sec 999 9hour 999hour 59min 9999hour 9999 9hour RESET RESET INHIBIT INHIBIT RESET RESET RESET RESET Max display value Max time range Max time range Max time range Max display value Max display value Max display value Max display value Max display value Max display value 0 0 ON 1 2 3 OFF ON 1 2 3 OFF ON 1 2 3 OFF ON 1 2 3 OFF ON 1 2 3 OFF...

Страница 7: ...E F F The display value continuesuntil reset signal is appliedthen output is held Retained output will be maintained until reset signal is applied N Display value and retained output are maintained until Reset signal is applied C The display value returns to reset start status as soon as display value is reached to preset value R The display value is held until output is OFF then returns to reset ...

Страница 8: ...ted spec when duty ratio is 1 3 It can not respond if it is smaller than min singal width Ta Error signal Error description Returning method Zero setting status Change the setting value to non zero status Reset function Reset In case of changing the input mode after supplying the power please take external reset or manual reset If reset is not executed the counter will be working as previous mode ...