Troubleshooting

Malfunction

Cause

Troubleshooting

Non-operation

Power supply

Supply the rated power.

Cable cut, disconnection

Check the wiring.

Non-operation in 

sometimes

Sensor cover pollution by dirt

Remove dirt by soft brush or cloth 

and set sensitivity again.

Connector connection failure

Check the connection area of 

connector.

Output is ON

without a target

Initial sensitivity setting goes 

wrong

Remove the cause and set 

sensitivity again.

There is a strong electric wave or

noise generator.

Put away motor, electric generator, 

or high voltage line.

Sold Separately: Connection cable

Model

L

C5D617-7P

7 m

C5D617-10P

10 m

C5D617-15P

15 m

43.5

L

1

2

3

7

4

6

5

1

2

3

7

4

6

5

Ø 5

Содержание BWM Series

Страница 1: ... the unit while connected to a power source Failure to follow this instruction may result in fire 04 Check Connections before wiring Failure to follow this instruction may result in fire 05 Do not disassemble or modify the unit Failure to follow this instruction may result in fire 06 This product is not safety sensor and does not observe any domestic nor international safety standard Do not use th...

Страница 2: ...or socket 6 pin OQ0655510000G ANYTEK SoldSeparately Connection cable C5D617 P OrderingInformation This is only for reference the actual product does not support all combinations For selecting the specified model follow the Autonics website BWM CL Optical axis pitch Number Optical axis pitch 25 mm Sensing CH Number 4 to 62 CH Operation mode L Light ON D Dark ON External device connection mode No ma...

Страница 3: ...ec M17 plug connector Output connector spec Connector type 4 pin 6 pin connector 5 08 mm pitch terminal type 10 pin terminal Material Case AL ABS sensing part and Indicator part PMMA CC LinkBaudRateandAddressSetting For CC Link setting communication speed of PLC Master and BWM should be the same Address is available from 1 to 64 and it should not be duplicated When changing CC Link setting turn OF...

Страница 4: ... and the product returns to the run mode after teaching completed 02 When the status display is D select channel to change using key and press key When number of channel is flashing set sensing level using key Functions Installation guide mode This function displays whether the sensing target is in the stable position of the guide line when installing the product through the output indicator Enter...

Страница 5: ...es Sensor cover pollution by dirt Remove dirt by soft brush or cloth and set sensitivity again Connector connection failure Check the connection area of connector Output is ON without a target Initial sensitivity setting goes wrong Remove the cause and set sensitivity again There is a strong electric wave or noise generator Put away motor electric generator or high voltage line SoldSeparately Conn...

Отзывы: