Features

• Stable glass substrate detection with using double scan method (patent)
• Sensing distance: glass G size +30 %
• Customized models available

 

: sensing channels (4 to 62 channels), optical axis pitch (25 to 200 mm) (patent)

• Communication output: CC-Link (ver 1.1, 2.0), EtherCAT
• Easy installation with installation instruction mode
• Mutual interference prevention, bent optical axis alarm, 9-stage sensing level setting, 

emitter error alarm

• Bright status indicators on slave units

ᜢ ᜣ ᜹

Safety Considerations

• Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
•  ᜸ symbol indicates caution due to special circumstances in which hazards may occur.

᜸ Warning

  

Failure to follow instructions may result in serious injury or death.

01. Fail-safe device must be installed when using the unit with machinery that 

may cause serious injury or substantial economic loss. (e.g. nuclear power 
control, medical equipment, ships, vehicles, railways, aircraft, combustion 
apparatus, safety equipment, crime/disaster prevention devices, etc.)

Failure to follow this instruction may result in personal injury, economic loss or 
fire.

02. Do not use the unit in the place where flammable/explosive/corrosive gas, 

high humidity, direct sunlight, radiant heat, vibration, impact, or salinity 
may be present.

Failure to follow this instruction may result in explosion or fire.

03. Do not connect, repair, or inspect the unit while connected to a power 

source.

Failure to follow this instruction may result in fire.

04. Check 'Connections' before wiring.

Failure to follow this instruction may result in fire.

05. Do not disassemble or modify the unit.

Failure to follow this instruction may result in fire.

06. This product is not safety sensor and does not observe any domestic nor 

international safety standard.

Do not use this product with the purpose of injury prevention or life protection, as 
well as in the place where economic loss maybe present.

᜸ Caution

  

Failure to follow instructions may result in injury or product damage.

01. Use the unit within the rated specifications.

Failure to follow this instruction may result in fire or product damage.

02. Use a dry cloth to clean the unit, and do not use water or organic solvent.

Failure to follow this instruction may result in fire.

03. Do not use a load over the range of rated relay specification.

Failure to follow this instruction may result in fire, relay broken, contact melt, 
insulation failure or contact failure.

Cautions during Use

• Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected 

accidents.

• 24 VDCᜡ power supply should be insulated and limited voltage/current or Class 2, 

SELV power supply device.

• Use the product, 1 sec after supplying power. When using separate power supply for 

the sensor and load, supply power to sensor first.

• When using switching mode power supply to supply the power, ground F.G. terminal 

and connect a condenser between 0 V and F.G. terminal to remove noise. 

• When connecting a DC relay or other inductive load, remove surge by using diodes 

or varistors. 

• Wire as short as possible and keep away from high voltage lines or power lines, to 

prevent surge and inductive noise.

• This unit may be used in the following environments.

 

- Indoors (in the environment condition rated in 'Specifications')

 

- Altitude max. 2,000 m 

 

- Pollution degree 2

 

- Installation category II

Содержание BWM Series

Страница 1: ... the unit while connected to a power source Failure to follow this instruction may result in fire 04 Check Connections before wiring Failure to follow this instruction may result in fire 05 Do not disassemble or modify the unit Failure to follow this instruction may result in fire 06 This product is not safety sensor and does not observe any domestic nor international safety standard Do not use th...

Страница 2: ...or socket 6 pin OQ0655510000G ANYTEK SoldSeparately Connection cable C5D617 P OrderingInformation This is only for reference the actual product does not support all combinations For selecting the specified model follow the Autonics website BWM CL Optical axis pitch Number Optical axis pitch 25 mm Sensing CH Number 4 to 62 CH Operation mode L Light ON D Dark ON External device connection mode No ma...

Страница 3: ...ec M17 plug connector Output connector spec Connector type 4 pin 6 pin connector 5 08 mm pitch terminal type 10 pin terminal Material Case AL ABS sensing part and Indicator part PMMA CC LinkBaudRateandAddressSetting For CC Link setting communication speed of PLC Master and BWM should be the same Address is available from 1 to 64 and it should not be duplicated When changing CC Link setting turn OF...

Страница 4: ... and the product returns to the run mode after teaching completed 02 When the status display is D select channel to change using key and press key When number of channel is flashing set sensing level using key Functions Installation guide mode This function displays whether the sensing target is in the stable position of the guide line when installing the product through the output indicator Enter...

Страница 5: ...es Sensor cover pollution by dirt Remove dirt by soft brush or cloth and set sensitivity again Connector connection failure Check the connection area of connector Output is ON without a target Initial sensitivity setting goes wrong Remove the cause and set sensitivity again There is a strong electric wave or noise generator Put away motor electric generator or high voltage line SoldSeparately Conn...

Отзывы: