-|Transparent Guide|-
Product Components
• Product
• Bracket
• Adjustment screwdriver
• Instruction manual
•
Bolt / Nut × 2
Connections
Dark ON
Light ON
12-24 VDCᜡ
NPN
LOAD
Brown
Black
Blue
White
Dark ON
Light ON
12-24 VDCᜡ
PNP
LOAD
Brown
Black
Blue
White
■ Selectable operation mode
Operation mode
Connection
Light ON
(White) control wire connects with (Blue) 0 V
Dark ON
(White) control wire connects with (Brown) + V
Dimensions
•
Unit: mm, For the detailed drawings, follow the Autonics website.
15
10.6
10
39.1
1
69.1
Ø5, 2m
17.7
42
2-Ø3.2
3.5
16.6
■
Bracket
4-R1.6
16
2-3.2
2
2
6
12
34.8
14
2
3.2
27
4 8
12
Circuit
■ NPN open collector output
■ PNP open collector output
Max. 200 mA
39 V
CIRC
UIT
LOAD
OCP
SCP
Max. 200 mA
39 V
CIRC
UIT
OCP
SCP
LOAD
•
OCP (over current protection), SCP (short circuit protection)
Sold Separately
•
Fiber optic units (except GT-420-13H2 model)
Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
BF3RX -
❶
❶
Control output
No mark: NPN open collector output
P: PNP open collector output
Max. 200 mA
Max. 200 mA
Mount and Removal of Amplifier
■
Mount
■
Removal
01.
Hang up the holder on the front
part of the amplifier to the DIN rail
or bracket.
02.
Press the stopper at the rear part
of the amplifier on the DIN rail or
bracket.
01.
Pull the stopper at the rear part
of the amplifier via a screwdriver
toward direction ①.
02.
Lift the rear part of the amplifier
toward direction ②.
Stopper
DIN rail
Stopper
①
②
DIN rail
Insert Fiber Optic Unit
01. Lower down the lever lock.
02.
Insert the cable of the fiber optic unit to the slot completely.
(▷ : receiver part, ◁ : emitter part)
a
b
Amplifier
Length (mm) Receiver part
Emitter part
a
01)
0
1
b
21
01) With the adaptor attached
03.
Lift the lever lock to fix the fiber optic unit.
Lever lock
①
③
②
Specifications
Power supply
12-24 VDCᜡ ±10% (ripple P-P: ≤ 10%)
Current consumption
≤ 40 mA
Control output
NPN open collector output / PNP open collector output model
Load voltage
≤ 30 VDCᜡ
Load current
≤ 200 mA
Residual voltage
NPN: ≤ 1 VDCᜡ, PNP: ≤ 2.5 VDCᜡ
Protection circuit
Reverse power protection circuit, output short overcurrent protection
circuit
Insulation resistance
≥ 20 MΩ (500 VDCᜡ megger)
Noise immunity
±240 VDCᜡ the square wave noise (pulse width: 1 ㎲) by the noise
simulator
Dielectric strength
1,000 VACᜠ 50 / 60 Hz for 1 min
Vibration
1 mm double amplitude at frequency of 10 to 55 Hz (for 1 min)
in each X, Y, Z direction for 2 hours
Shock
500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times
Ambient illuminance
(receiver)
Sunlight: ≤ 11,000 lx, incandescent lamp: ≤ 3,000 lx
Ambient temperature
-10 to 50 ℃, storage: -25 to 70 ℃ (no freezing or condensation)
Ambient humidity
35 to 85%RH, storage: 35 to 85%RH (no freezing or condensation)
Cable spec.
Ø 5 mm, 4-wire, 2 m
Wire spec.
AWG24 (0.08 mm, 40-core), insulator outer diameter: Ø 1 mm
Material
Case: ABS, cover: PC
Model
BF3RX-□
Light source
Red LED
Peak emission
wavelength
660 nm, modulated
Response time
≤ 1 ms
Sensitivity setting
Manual sensitivity setting (adjuster)
Operation mode
Light ON / Dark ON selectable (control wire)
Indicator
Operation indicator (red)
Approval
ᜫ
Unit weight
≈ 90 g