background image

-|Transparent Guide|-

Product Components

• Product 
• Bracket 
• Adjustment screwdriver

• Instruction manual 

• 

Bolt / Nut × 2

Connections

Dark ON

Light ON

12-24 VDCᜡ

NPN

LOAD

Brown

Black

Blue

White

Dark ON

Light ON

12-24 VDCᜡ

PNP

LOAD

Brown

Black

Blue

White

  

■ Selectable operation mode

Operation mode

Connection

Light ON

(White) control wire connects with (Blue) 0 V

Dark ON

(White) control wire connects with (Brown) + V

Dimensions

• 

Unit: mm, For the detailed drawings, follow the Autonics website.

15

10.6

10

39.1

1

69.1

Ø5, 2m

17.7

42

2-Ø3.2

3.5

16.6

  

Bracket

4-R1.6

16

2-3.2

2

2

6

12

34.8

14

2

3.2

27

4 8

12

Circuit

  

■ NPN open collector output

  

■ PNP open collector output

Max. 200 mA 

39 V

CIRC

UIT

LOAD

OCP

SCP

Max. 200 mA 

39 V

CIRC

UIT

OCP

SCP

LOAD

• 

OCP (over current protection), SCP (short circuit protection)

Sold Separately

• 

Fiber optic units (except GT-420-13H2 model)

Ordering Information

This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.  

BF3RX -

❶ 

Control output

No mark: NPN open collector output

P: PNP open collector output

Max. 200 mA

Max. 200 mA

Mount and Removal of Amplifier  

  

Mount

  

Removal

01. 

Hang up the holder on the front 

part of the amplifier to the DIN rail 

or bracket.

02. 

Press the stopper at the rear part 

of the amplifier on the DIN rail or 

bracket.

01. 

Pull the stopper at the rear part 

of the amplifier via a screwdriver 

toward direction ①.

02. 

Lift the rear part of the amplifier 

toward direction ②.

Stopper

DIN rail

Stopper

DIN rail

Insert Fiber Optic Unit 

01. Lower down the lever lock.

02. 

Insert the cable of the fiber optic unit to the slot completely.

 

(▷ : receiver part, ◁ : emitter part)

a

b

Amplifier

Length (mm) Receiver part

Emitter part

01)

0

1

b

21

01) With the adaptor attached 

03. 

Lift the lever lock to fix the fiber optic unit.

Lever lock

Specifications

Power supply

12-24 VDCᜡ ±10% (ripple P-P: ≤ 10%)

Current consumption

≤ 40 mA

Control output

NPN open collector output / PNP open collector output model

Load voltage

≤ 30 VDCᜡ

Load current

≤ 200 mA

Residual voltage

NPN: ≤ 1 VDCᜡ, PNP: ≤ 2.5 VDCᜡ

Protection circuit

Reverse power protection circuit, output short overcurrent protection 

circuit

Insulation resistance

≥ 20 MΩ (500 VDCᜡ megger)

Noise immunity

±240 VDCᜡ the square wave noise (pulse width: 1 ㎲) by the noise 

simulator

Dielectric strength

1,000 VACᜠ 50 / 60 Hz for 1 min

Vibration

1 mm double amplitude at frequency of 10 to 55 Hz (for 1 min) 

in each X, Y, Z direction for 2 hours

Shock

500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times

Ambient illuminance

(receiver)

Sunlight: ≤ 11,000 lx, incandescent lamp: ≤ 3,000 lx 

Ambient temperature

-10 to 50 ℃, storage: -25 to 70 ℃ (no freezing or condensation)

Ambient humidity

35 to 85%RH, storage: 35 to 85%RH (no freezing or condensation)

Cable spec.

Ø 5 mm, 4-wire, 2 m

Wire spec.

AWG24 (0.08 mm, 40-core), insulator outer diameter: Ø 1 mm

Material

Case: ABS, cover: PC

Model

BF3RX-□

Light source

Red LED

Peak emission 

wavelength

660 nm, modulated

Response time

≤ 1 ms

Sensitivity setting

Manual sensitivity setting (adjuster)

Operation mode

Light ON / Dark ON selectable (control wire)

Indicator

Operation indicator (red)

Approval

Unit weight 

≈ 90 g