-|Transparent Guide|-
Wire Ferrule Specifications
• Unit: mm, Use the UL approved wire ferrule.
10 to 12
≤ 2.0
≤ 4.1
Sold Separately
• I/O cable
Rated voltage
01)
Basic model: ≤ 125 VDCᜡ, 125 VACᜠ 50/60 Hz
Indicator equipped model: ≤ 24 VDCᜡ ± 10%
Rated current
≤ 1 A
Insulation
resistance
≥ 1,000 MΩ (500 VDCᜡ megger)
Dielectric
strength
2,700 VACᜠ 50/60 Hz for 1 minute
Vibration
0.75 mm amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z
direction for 2 hours
Vibration
(malfunction)
0.75 mm amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z
direction for 10 minutes
Shock
150 m/s
2
(≈ 15 G) in each X, Y, Z direction for 3 times
Shock
(malfunction)
100 m/s
2
(≈ 10 G) in each X, Y, Z direction for 3 times
Ambient
temperature
-15 to 55 ℃, storage: -25 to 65 ℃
(a non freezing or condensation environment)
Ambient
humidity
35 to 85 %RH, storage: 35 to 85 %RH
(a non freezing or condensation environment)
Protection
structure
IP20 (IEC standard)
01) When connecting loads to output part, connect loads of same power type. Connecting loads of different power
type may cause safety issues.
Model
AFL-H20
AFL-H26
AFL-H40
AFL-H50
AFL-H50B
The number of
connector pin
20
26
40
50
50
The number of
terminal
20
26
40
50
50
Terminal type
Screwless
Screwless
Screwless
Screwless
Screwless
Terminal pitch
5.0 mm
5.0 mm
5.0 mm
5.0 mm
5.0 mm
Connector for
controller side
20-pin Omron
(XG4A-2031)
26-pin Omron
(XG4A-2631)
40-pin Hirose
(HIF3BA-40PA-
54DSA)
50-pin Hirose
(HIF3BA-50PA-
2.54DSA)
50
-pin
Hirose
(HIF3BB-50PA-
2.54DSA)
Material
Case, Base: PC
Approval
ᜢ ᜨ
Unit weight
(packaged)
≈ 48.5 g
(≈ 86.2 g)
≈ 60 g
(≈ 89 g)
≈ 89 g
(≈ 156 g)
≈ 110 g
(≈ 177 g)
≈ 110 g
(≈ 177 g)
Model
AFL-H20-LN, AFL-H20-LP
AFL-H40-LN, AFL-H40-LP
The number of
connector pin
20
40
The number of
terminal
16
01)
32
02)
Terminal type
Screwless
Screwless
Terminal pitch
5.0 mm
5.0 mm
Connector for
controller side
20-pin Omron (XG4A-2031)
40-pin Hirose (HIF3BA-40PA-2.54DSA)
Input logic
NPN / PNP model
Indicator
Power indicator: red, operation indicator: blue
Material
Case, Base: PC
Approval
ᜢ ᜨ
Unit weight
(packaged)
≈ 48.6 g
(≈ 86.3 g)
≈ 91 g
(≈ 158 g)
01) Four terminals among twenty terminals are used for LED power.
02) Eight terminals among fourty terminals are used for LED power or N.C (Not Connectred) terminals.
Specifications
Applicable wire
- solid
01)
Ø 0.3 to 1.2 mm
Applicable wire
- stranded
01) 02)
AWG 22-16 (0.30 to 1.25 mm²)
Wire ferrule
connection
tensile strength
≥ 30 N
Stripped length
8 to 10 mm
01) Use the cable of copper conductor in 60 ℃ temperature class.
02) When using the stranded wire, use End Sleeve (wire ferrule).
❶ The number of connector pin
20: 20-pin
26: 26-pin
40: 40-pin
50: 50-pin
❸ Indicator
No-mark: no LED
L: LED equipped
❷ Connector
No-mark: HIF3BA, XG4A-2031, XG4A-2631
B: HIF3BB
❹ Input logic
No-mark: None
N: NPN
P: PNP
Ordering Information
This is only for reference.
For selecting the specific model, follow the Autonics web site.
AFL
-
H
❶ ❷
-
❸ ❹
Installation
■
DIN RAIL
•
Mounting
1. Pull the Rail lock on the rear of the product to the direction ①.
2. Hang DIN rail hook on the rear of the product onto DIN rail.
3. Push the product to the direction ②, and push the Rail lock to the direction ③ to fix
onto the DIN rail.
①
②
③
Rail lock
DIN rail hook
DIN rail
•
Removing
1. Insert a tool such as screwdriver into the hole of Rail lock.
2. Push the toll to the direction ① and pull the Rail lock.
3. Lift bottom of the product to the direction ② and remove the product from DIN rail.
①
Rail lock
②
■
Panel
Product with the mounting hole can be installed on panel with screw.
It is recommended to use M4×25 mm of spring washer screws.
If you use flat washer, its diameter should be Ø 8 mm.
Tighten the screw with the tightening torque of 0.7 to 1.0 N·m.
Mounting hole
Dimensions
•
Unit: mm, For the detailed dimensions of the product, follow the Autonics web site.
A
B
C
D
20-pin
57.5
53
2-Ø4.2
53
26-pin
72.5
64
2-Ø4.2
64
40-pin
106.5
89
2-Ø4.5
89
50-pin
131.5
102
2-Ø4.5
102
A
C
B
35 mm DIN RAIL
D
39
8.5
46.5
48.8
2-M4
Wiring
•
Connecting
Insert the wire ferrule into the terminal hole.
•
Removing
1. Put the (-) screwdriver at the groove on the clamp lever
and press it.
2. Pull the cable to disassemble.
3