Product Components

• 

Sensor: ADS-SHP (1 set - emitter and receiver)

• Fixing bolt for the controller (M4×20) × 2

Sold Separately

• 

Mounting bracket: ADS-SB12 (one push method)

• 

Mounting bracket: ADS-SB10 (screw method)

• 

Sensor: ADS-SHP (1 set - emitter and receiver)

• 

Controller: ADS-SEC

Recommended Installation for the Sensor

1.  Refer to the below and drill the holes on the side pillars of the auto door

 

for the installation. 

• 

Check the mounting holes of the head of the emitter and receiver are in parallel for the 
optical axes

• 

Grind around the mounting holes drilled smoothly.

 

It may hurt by sharp parts and cause malfunction by the inclined sensor head.

One push method

Screw method

Using 

the bracket 

Through hole for sensor head

Ø 13 to 14 mm

Fixing screw hole for bracket

M4 Tap or Ø 3 mm

Not using 

the bracket

Mounting hole for sensor head

Ø 12.2

±0.1

 mm

M10 × 0.75 mm

Panel thickness for sensor head

1.5

±0.5

 mm

1.5

±0.5

 mm

2. Mount the sensor heads to the mounting holes.

• 

It may cause malfunction because the sensitivity setting is not available as the optical 
axes are not matched if the sensor body is inclined.

• 

Check the damage such as scratches or pollutant on the lens of the sensor head.

 

It may cause malfunction in the condition of interrupted light or lack of sensitivity by 
dust.

• 

Be sure to use the mounting brackets of the one push method for the sensor with the 
head holder and nuts. In the one push method, check the nuts are fixed on the sensor 
body tightly.

 

Install the sensor with no gap between the nut and the side of the door or panel.

• 

Be sure to use the mounting brackets of the screw method for the sensor without the 
head holder and nuts. 

 

Install the sensor with no gap between the panel and the sensor.

One push method

Screw method

Using 

the bracket 

Install the sensor head to the bracket 

first and fix the bracket to the desired 

place by the screws.

Remove the nut and head holder from 

the sensor head first. Install the sensor 

head to the bracket and fix the bracket 

on the side pillar of the door by the 

screws.

Through hole for 

sensor head

: Ø 13 to 14 mm

M4 flat

head screw

Bracket

Head holder

Nut

Through hole for

sensor head

: Ø 13 to 14 mm

Screw hole: 

M4 Tap or

 Ø 3.5 mm

Bracket

Not using 

the bracket

Put the sensor head into the mounting hole.

  

■ Cautions during installation

• 

The rated sensing distance is max. 10 m (A).

 

Install the sensors within the rated sensing distance.

• 

Install the sensor with more than 50 cm (B) gap from

 

the bottom and ceiling. It may cause malfunction by 
reflected beams from the surface of the bottom and 
ceiling.

• 

Do not put obstacles between the emitter and 
receiver. Otherwise, it may result in malfunction

B

B

A

[Fig. 1]

Cautions during Installation

• 

Install the unit correctly with the usage environment, location, and the designated 
specifications. 

• 

When installing over the two door sensors closely, it may result in malfunction due to 
mutual interference. Do not change the position of the head of emitter and receiver. 
Keep the installation distance between the two heads more than 50 cm.

• 

This product is for indoor only.

 

Avoid the place where the receiver is exposed to direct sunlight, or the ambient 
illumination is in over the rated value.

• 

Do NOT impacts with a hard object or excessive bending of the wire lead-out. It may 

cause damage the water resistance

Recommended Installation for the Controller

1.  Refer to the figure at the right side and adjust 

the length of wires.

• 

Cut off the wires as much as your need and take off 

the cover of them. Twist the end of the wires shown 

in the figure, and connect to the controller. 

 

It is easy to connect if soldering the end of the wires.

• 

Be sure to connect the wires in power OFF.

• 

Follow the figure when cutting off the wires of the 

sensor head. If taking off the cover too much, it may 

cause damage to this product as the end of both 

wires are in contact with each other.

Outer shield wire

17 mm

9 mm

Inner covered wire

2. Match wires in the number of terminals and connect them.

• 

Do not connect the extended wire to the sensor. 

 

It may cause malfunction by the noise.

• 

Do not connect 2 wires or more to the 1 terminal.

 

ADS-SE1

ADS-SE2

Output

(N.O.)(N.C.)

Power

(12-24 VACᜠ / VDCᜡ)

Emitter

(gray)

Receiver

(blue)

Power

(12-24 VACᜠ / VDCᜡ)

Output

(N.O.)(N.C.)

Emitter

(gray)

Receiver

(blue)

① ②

  

■  Connection for sensor / power / output wirings

• 

Press the wiring connection buttons and connect 

the wires.

• 

It does not operate normally if the wires are 

connected conversely. Before the wiring, be sure to 

check the proper positions of the wires.

• 

Make sure that the power wire connects to the 

power terminal (4, 5). Otherwise, it may cause 

damage to this product.

• 

Allowable diameter: in case of the power and output 

line

 

- Single and stranded wire: 0.2 to 1.5 mm

2

  

■ Cautions during installation

• 

Fix a controller with offered 2 fixing bolts.

 

Process the fixing holes of a controller by M4 and see the ' Dimensions' for the position 

of holes. 

• 

Do not over tighten the bolts when fixing the controller. The fixing holes may be 

broken.

Power supply

12 - 24 VACᜠ ± 10 %, 50 / 60 Hz / 12 - 24 VDCᜡ ± 10 % (ripple P-P: ≤ 10 %)

Power consumption

AC: ≤ 2 VA / DC: ≤ 50 mA

Control output

Relay contact output

Relay contact capacity

 01)

50 VDCᜡ 0.3 A (resistive load)

Relay contact composition

1c

Relay life cycle

Mechanical: ≥ 5,000,000 times, electrical: ≥ 100,000 times

Insulation resistance

≥ 20 MΩ (500 VDCᜡ megger)

Vibration

1 mm double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z 

direction for 2 hours

Shock

500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times

Ambient illumination 

(receiver)

Sunlight: ≤ 100,000 ㏓

Ambient temperature

-20 to 55 ℃, storage: -25 to 60 ℃ (no freezing or condensation)

Ambient humidity

35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)

Protection structure

IP30 (IEC standard)

Connection 

Cable connector type

Sensor cable

Ø 2.4 mm, 1-wire, 5 m

Wire spec.

AWG26 (0.16 mm, 7-core), insulator outer diameter: Ø 1.32 mm

Material of the controller

Housing: ABS, cover: ABS, bolt: SCM (brass, Ni-plate)

Material of the sensor

Holder: ABS, lens: PMMA, lens guide: PC, nut: PC

 01)   Do not use the load which is beyond the rated capacity of contact point of relay.

 

It may cause bad insulation, contact fusion, bad contact, relay breakdown, and fire etc.

Model

ADS-SE1

ADS-SE2

Available sensor sets

1 channel

2 channels

Sensing distance

0 to 10 m

Sensing target

Opaque materials

Min. sensing target

≥ Ø 20 mm

Sensing method

Through-beam type

Response time

≈ 50 ms (from interrupted light)

Output holding time

≈ 500 ms (from received light)

Light source

Infrared LED (850 nm modulated)

Indicator

OUT 1 indicator (red), OUT 2 indicator (green)

Approval

ᜢ ᜫ

Weight (packaged)

≈ 300 g (≈ 450 g)

Specifications