background image

-|Transparent Guide|-

TCD210004AA

Automatic

Door Side Sensors

ADS-SE1/2 Series

PRODUCT MANUAL

For your safety, read and follow the considerations written in the instruction 
manual, other manuals and Autonics website.

The specifications, dimensions, etc. are subject to change without notice for product 
improvement. Some models may be discontinued without notice. 

ᜢ ᜫ

Features

• 

Long sensing distance: 0 to 10 m

• 

High ambient intensity of illumination

 

: max. 100,000 lx of sunlight

• 

Easy to connect the sensor head to the controller

• 

Easy sensitivity setting (automatic sensitivity setting by one push method)

• 

Self-diagnosis function

• 

Compact Size (W 77 × L 44 × H 24 mm)

Safety Considerations

• 

Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.

• 

᜸ symbol indicates caution due to special circumstances in which hazards may occur.

᜸ Warning

  

Failure to follow instructions may result in serious injury or death.

01. 

Fail-safe device must be installed when using the unit with machinery that 

may cause serious injury or substantial economic loss.(e.g., nuclear power 

control, medical equipment, ships, vehicles, railways, aircraft, combustion 

apparatus, safety equipment, crime/disaster prevention devices, etc.)

Failure to follow this instruction may result in personal injury, economic loss or fire.

02. 

Use this product as secondary safety aid for door sensor.

Failure to follow this instruction may result in personal injury or economic loss.

03. 

Since the purpose of this product is secondary safety aid, please use it with 

another door sensor.

-  Although install this product near the sensing area, object in the nearest area  

 

from the door can not be detected. It is hard to detect kids or elders consecutively, 

they can be caught by the auto door.

-   Keep opened as much as the holding time you set. Since door closes after the 

holding time, the people can be caught by the auto door.

04. 

Do not connect, repair, or inspect the unit while connected to a power 

source.

Failure to follow this instruction may result in fire.

05. 

Do not use the unit in the place where flammable/explosive/corrosive gas, 

high humidity, direct sunlight, radiant heat, vibration, impact or salinity 

may be present.

Failure to follow this instruction may result in explosion or fire.

06. 

Check ‘Connections’ before wiring.

Failure to follow this instruction may result in fire.

07. Do not disassemble or modify the unit.

Failure to follow this instruction may result in fire.

᜸ Caution

  

Failure to follow instructions may result in injury or product damage.

01. 

Use the unit within the rated specifications.

Failure to follow this instruction may result in fire or product damage. 

02. 

Use a dry cloth to clean the unit, and do not use water or organic solvent.

Failure to follow this instruction may result in fire.

03. 

Do not use a load over the range of rated relay specification.

Failure to follow this instruction may result in fire, relay broken, contact melt, 

insulation failure or contact failure.

Cautions during Use

• 

Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected 

accidents.

• 

12 - 24 VDCᜡ, 12 - 24 VACᜠ power supply should be insulated and limited voltage / 

current or Class 2, SELV power supply device.

• 

Use the product, 1 sec after supplying power.

 

When using separate power supply for the sensor and load, supply power to sensor 

first.

• 

When using switching mode power supply (SMPS) to supply the power, ground F.G. 

terminal and connect a condenser between 0V and F.G. terminal to remove noise. 

• 

When connecting a DC relay or other inductive load, remove surge by using diodes or 

varistors.

• 

Wire as short as possible and keep away from high voltage lines or power lines, to 

prevent surge and inductive noise.

• 

This unit may be used in the following environments.

 

- Indoors (in the environment condition rated in ‘Specifications’)

 

- Altitude max. 2,000 m

 

- Pollution degree 3

 

- Installation category II

Отзывы: