1. Overview

The IC 995 is the latest in the developing range of IC 900 Series Information
Centres. In addition to the standard measured features of its predecessors,
the IC 995 breaks new ground. Its large graphic display enables tabulated, 
bar and line graphs of Harmonic content, making the IC 995 a true 
engineering network analyser. 

Built-in Modbus Communication, Voltfree Pulsed output, programmable Digital inputs 

and outputs ensure simple, accurate, remote monitoring of data, particularly when 

used in conjunction with the Autometers Horizon Monitoring System. 

User-friendly installation, programming and operation make the IC 995 the choice 

of installers, operators and engineers alike. This, combined with Protocol compatibility 

across the Autometers Range, ensures that network communication remains one of the 

key strengths of the Information Centre Range. 

Autometers Information Centres - Simple, Reliable, Accurate. 

Product development is continuous and Autometers Systems Ltd reserves the
right to make alterations and manufacture without notice. 
Products as delivered may therefore differ from the descriptions and illustrations
in this publication.

Publication No. IC995.01.09.09

Содержание IC 995

Страница 1: ...ly when used in conjunction with the Autometers Horizon Monitoring System User friendly installation programming and operation make the IC 995 the choice of installers operators and engineers alike Th...

Страница 2: ...at 10kWh pulse and 1 RS485 Modbus protocol output in order to satisfy remote meter reading and system control monitoring 3 Technical features FEATURE VALUES Network 1PH2W 3P3W 3P4W Frequency 45 65Hz...

Страница 3: ...70v Wiring Electrical and communication connections are made directly to the back of the meter See diagram to right There are three blocks of green connectors the two at the top can be unplugged the o...

Страница 4: ...d be as our diagrams on page 5 Mode of wiring 1 element 1P2W 2 element 3P3W 3 element 3P4W Match the voltage input with current input and match the phase and phase sequence otherwise the values or sig...

Страница 5: ...am 1 WAVEFORM diagram 2 BAR diagram 3 VALUE To select VALUE move the cursor over the word Value by pressing the key with the arrow facing down and then press return Here you will be able to view the i...

Страница 6: ...ance The unbalance voltage or current of 3 phase can be divided into positive component negative component and zero component The screen displays Vu f Voltage unbalanced factor Iuf Current unbalanced...

Страница 7: ...the status of the digital inputs and outputs relays The digital input is powered by 5V and digital output is a pair of non powered contacts If programmed the status will change to ON these relays are...

Страница 8: ...o you can enter your number in the correct sequence 8 Network Move the highlighted feature up or down by pressing the arrows marked to the Network line The cursor will move over the 3p4w symbol to alt...

Страница 9: ...hlighted with the rst number on the left 001 to change this to 015 read below First press the key with the arrow pointing down this will move the cursor one stop to the right Now press the key with th...

Страница 10: ...l through the options When you have selected your option press the key with the arrow facing down this will move the cursor to the four digits on the left 0000 this is the time the relay will stay ope...

Отзывы: