background image

Page 5

IronHorse GSD3 DC Drives User Manual  –  1st Ed, Rev C  –  10/15/2019

Selection and Specifications

GSD3 Series DC Drives – Selection & Specifications

Model

GSD3- 

24A-2CJ

GSD3- 

24A-2CL

GSD3-24A-3N4

GSD3- 

240-2CJ

GSD3- 

240-2CL

GSD3-240-3N4

Package Configuration

open frame

NEMA 4

open frame

NEMA 4

Power Quality Form Factor

1.4

Input Voltage  (@ 50/60 Hz)

12 or 24 VAC ±10%

120 or 240 VAC ±10%

Output Voltage

0–12 or 0–24 VDC

0–90 or 0–180 VDC

Shunt Field Voltage & Current

10 VDC @ 12 VAC 

20 VDC @ 24 VAC 

(1A max)

10 VDC @ 12 VAC  

20 VDC @ 24 VAC 

(0.75A max)

100 VDC @ 120 VAC 

200 VDC @ 240 VAC 

(1A max)

100 VDC @ 120 VAC  

200 VDC @ 240 VAC 

(0.75A max)

Output Rating (hp)

1/50 – 1/40 @ 12V 

1/25 – 1/20 @ 24V

1/50 – 1/25 @ 12V 

1/25 – 1/12 @ 24V

1/50 – 1/6 @ 90V 

1/25 – 1/3 @ 180V

1/50 – 1/3 @ 90V 

1/25 – 2/3 @ 180V

Output Current (continuous)

150 mA to 2A (DC)

150 mA to 3A (DC)

150 mA to 2A (DC)

150 mA to 3A (DC)

Current Overload Capacity

200% for 60s

Current Limit

n/a

Transient Protection

Metal Oxide Varistor (MOV)

I.R. Compensation

adjustable – full range

Speed Adjustment

5kΩ potentiometer

Speed Range

25:1

Speed Regulation

±1% of base speed

Maximum Speed

adjustable from 40% to 120% of base speed

Minimum Speed

adjustable from 0% to 30% of maximum speed

Acceleration

0.5s (fixed)

Deceleration

0.5s (fixed)

Dynamic Braking

no

Plugging Capability **

no

Electrical Connections

spade connector lugs

External Fusing Required

Internal fusing is included which is adequate for GSD3-240-3N4 120 VAC line and neutral inputs.

Refer to “Fusing” (page 7) and “Wiring Diagrams” (page 7) for external fusing requirements for 

other wiring configurations.

Operating Temperature

-10 to 45 °C 

[14 to 113 °F]

-10 to 40 °C 

[14 to 104 °F]

-10 to 45 °C 

[14 to 113 °F]

-10 to 40 °C 

[14 to 104 °F]

Thermal Protection

none

Mounting Orientation

can be mounted in any orientation

Corrosive Gases

NOT compatible with any corrosive gases

Weight

2.9 oz  

[83g]

2.6 oz  

[75g]

20.3 oz  [575g]

2.9 oz  

[83g]

2.6 oz  

[75g]

20.3 oz  [575g]

Agency Approvals

RoHS

C

UL

US

 Listed (E333109), RoHS

Optional Accessories *

Replacement Potentiometer

GSDA-5K

Manual Reverse Switch

GSDA-MREV***

* For accessories details, please visit www.AutomationDirect.com.

** Plugging is a method of rapidly changing motor direction by reversing motor armature polarity, while the motor is still running.

*** To meet NEMA4 requirements, GSDA-MREV requires a user provided external exclosure.

Содержание IRONHORSE GSD3 Series

Страница 1: ...Page 1 IronHorse GSD3 DC Drives User Manual 1st Ed Rev C 10 15 2019 GSD3 Series DC Drives User Manual User Manual Number IH GSD3 User M...

Страница 2: ...le as on line control equipment in hazardous environments requiring fail safe performance such as in the operation of nuclear facilities aircraft navigation or communication systems air traffic contro...

Страница 3: ...included in this manual Who Should Read This User Manual This manual contains important information for those who will install maintain and or operate any of the GSD3 Series DC Drives Technical Suppor...

Страница 4: ...ts Standard Features Dual voltage models of 12 24 VAC or 120 240 VAC input Full wave bridge power supply Adjustable minimum and maximum speeds Adjustable IR Compensation Fixed Acceleration 0 5 seconds...

Страница 5: ...on 1 of base speed Maximum Speed adjustable from 40 to 120 of base speed Minimum Speed adjustable from 0 to 30 of maximum speed Acceleration 0 5s fixed Deceleration 0 5s fixed Dynamic Braking no Plugg...

Страница 6: ...Page 6 IronHorse GSD3 DC Drives User Manual 1st Ed Rev C 10 15 2019 Dimensions GSD3 24x 2CJ dimensions in mm GSD3 24x 2CL dimensions in mm GSD3 24x 3N4 dimensions in mm...

Страница 7: ...it the voltage drop through the wiring to 5 of the line voltage at full load CAUTION Turn power OFF while making wiring connections CAUTION Do not attempt to perform a hi pot test across the AC lines...

Страница 8: ...n the CW direction until the maximum desired speed is obtained 5 Turn the Speed pot fully CCW 6 Adjust the MIN trim pot in the CW direction until deadband or the desired speed is obtained TRIM POT ADJ...

Страница 9: ...Page 9 IronHorse GSD3 DC Drives User Manual 1st Ed Rev C 10 15 2019 BLANK PAGE...

Страница 10: ...Page 10 IronHorse GSD3 DC Drives User Manual 1st Ed Rev C 10 15 2019 BLANK PAGE...

Страница 11: ...Page 11 IronHorse GSD3 DC Drives User Manual 1st Ed Rev C 10 15 2019 BLANK PAGE...

Страница 12: ...Page 12 IronHorse GSD3 DC Drives User Manual 1st Ed Rev C 10 15 2019 Literature Number LT134 Drawing Number A 5 3901C...

Отзывы: