Note: 

SPARE denotes deselected channel 

Momentarily Press 

SEL

 button to

toggle through

secondary displays

Hold 

SEL

 button down to cycle through primary screens. Release button to select screen.

Power On

Appears

initially

These screens will 

then auto cycle

Error Messages – 

An existing error will 

be inserted into the cycling Status Info screen

This screen will 

auto cycle with

status information

Fault Messages – 

Appear 

in place of data during a 

fault condition.

On if input is

greater than or 

equal to 20 mA.

On if input is 

less than or 

equal to 0 mA.

PASSED
SELF
TEST

P2-
8AD4DA-1 
Fw. Rev.
 1.00

In:
0-20mA
Out:
4-20mA

Channels
Enabled:
7

DISPLAY
SETUP
INFO

DISPLAY
STATUS
INFO

DISPLAY
UNITS
DECIMAL
COUNTS

DISPLAY
UNITS
HEX
COUNTS

DISPLAY
UNITS
mA

End of
Status
Menu
List

MISSING
EXTERNAL
24VDC

SELFTEST
FAIL
REPLACE
MODULE

End of
Status
Menu
List

MISSING
CONFIG
DATA

1

I

 00000

2

I

 00000

3

I

 00000

4

I

 00000

5

I

 00000

6

I

 00000

7

I

 00000

8

I

 SPARE

1

I

  0 0 0 0 0

2

I

  0 0 0 0 0

3

I

  0 0 0 0 0

4

I

  0 0 0 0 0

5

I

  0 0 0 0 0

6

I

  0 0 0 0 0

7

I

  0 0 0 0 0

8

I

  S P A R E

1

O

 00000

2

O

 00000

3

O

 00000

4

O

 00000

1

I

 0000H

2

I

 0000H

3

I

 0000H

4

I

 0000H

5

I

 0000H

6

I

 0000H

7

I

 0000H

8

I

 SPARE

1

I

  0 0 0 0 H

2

I

  0 0 0 0 H

3

I

  0 0 0 0 H

4

I

  0 0 0 0 H

5

I

  0 0 0 0 H

6

I

  0 0 0 0 H

7

I

  0 0 0 0 H

8

I

  S P A R E

1

O

 0000H

2

O

 0000H

3

O

 0000H

4

O

 0000H

1

I

00.0mA

2

I

00.0mA

3

I

00.0mA

4

I

00.0mA

5

I

00.0mA

6

I

00.0mA

7

I

00.0mA

8

I

 SPARE

1

I

0 4 . 0 m A

2

I

0 4 . 0 m A

3

I

0 4 . 0 m A

4

I

0 4 . 0 m A

5

I

0 4 . 0 m A

6

I

0 4 . 0 m A

7

I

0 4 . 0 m A

8

I

  S P A R E

1

O

04.0mA

2

O

04.0mA

3

O

04.0mA

4

O

04.0mA

1

I

  OVER

2

I

 UNDER

3

I

 

4

I

 

OLED Panel Display

Содержание Productivity 2000 P2-8AD4DA-1

Страница 1: ...movable Terminal Block Specifications 8 General Specifications Operating Temperature 0 to 60 C 32 to 140 F Storage Temperature 20 to 70 C 4 to 158 F Humidity 5 to 95 non condensing Environmental Air N...

Страница 2: ...4 1 common Module Signal Output Range 4 20 mA Output Signal Resolution 16 bit Resolution Value of LSB least significant bit 0 244 A count 1 LSB 1 count Data Range 0 65535 counts Output Type Current so...

Страница 3: ...C User Supplied Power An Edison S500 32 R 0 032A fast acting fuse is recommended for all 4 20 mA current loops 032A fuse I1 I2 I3 I4 I5 I6 I8 I7 COM 0V 24V 24 VDC User Supplied Power CH1 ADC CH2 ADC C...

Страница 4: ...your installation for use of this powerful feature 1 Align with slot 2 rotate to seated position Module Installation WARNING Do not apply field power until the following steps are completed See hot s...

Страница 5: ...n a User Tagname to each input and output point channel selected and to each Status Bit Item Module Configuration Wiring Options 1 ZIPLink Connection System Cable ZIPLink Module Complete System ZIPLin...

Страница 6: ...nk Level 7 0 0 0 0 0 0 0 Select the minimum and maximum values of the raw input signal These values will relate to the minimum and maximum scaled values 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 The Scale Linear...

Страница 7: ...US INFO DISPLAY UNITS DECIMAL COUNTS DISPLAY UNITS HEX COUNTS DISPLAY UNITS mA End of Status Menu List MISSING EXTERNAL 24VDC SELFTEST FAIL REPLACE MODULE End of Status Menu List MISSING CONFIG DATA 1...

Страница 8: ...ion or operation If you have any questions concerning the installation or operation of this equip ment or if you need additional information please call Technical Support at 770 844 4200 This publicat...

Отзывы: