background image

5

Sales 800-633-0405

www.productivity2000.com

Module Configuration

8CH, 13-BIT, VOLTAGE, ANALOG INPUT

Using the Hardware Configuration tool in the 

Productivity Suite programming software, drag 

and drop the P2-08ADL-2 module into the 

base configuration. 

  

Select 

Automatic Module Verification

 or 

No 

Verification and Enable Hot Swap

. If desired, 

assign a 

User Tagname

 to each input point 

(channel) selected and to each 

Status Bit Item

.

Wiring Options

 

1

ZIPLink Feed Through Modules and Cables¹

0.5 m (1.6 ft) cable

1.0 m (3.3 ft) cable

2.0 m (6.6 ft) cable

ZL-RTB20
ZL-RTB20-1

ZL-P2-CBL18
ZL-P2-CBL18-1
ZL-P2-CBL18-2

       Terminal Block with pigtail cable

1.0 m (3.3 ft) cable

2.0 m (6.6 ft) cable

ZL-P2-CBL18-1P

ZL-P2-CBL18-2P

3

Screw Terminal Block only

P2-RTB
(Quantity 1)

4

Spring Clamp Terminal Block only

P2-RTB-1
(Quantity 1)

5

 

Accessories²

ZL-RTB-COM

TW-SD-SL-1

TW-SD-MSL-1

ZL-RTB20

ZL-RTB20-1

2

1.Cable + 

ZIP

Link Module = Complete System

2. ZL-RTB-COM provides a common connection point for power or ground

Содержание Productivity 2000 P2-08ADL-2

Страница 1: ...s available at the time it was printed At AutomationDirect com we constantly strive to improve our products and services so we reserve the right to make changes to the products and or publications at any time without notice and without any obligation This publication may also discuss features that may not be available in certain revisions of the product Removable Terminal Block Specifications Part...

Страница 2: ...ained at www productivity2000 com Terminal Type 18 position Removable Terminal Block Weight 100g 3 5 oz Input Specifications Input Channels 8 Module Signal Input Range 0 10 VDC Resolution 13 bit Data Range 0 8191 counts Input Type Single ended 1 common Resolution Value of LSB 0 10 VDC 1 22 mV per count 1 LSB 1 Count Maximum Continuous Overload 100VDC Input Impedance 150kΩ Filter Characteristics Lo...

Страница 3: ...C CH7 ADC CH8 ADC ISOLATED ANALOG CIRCUIT POWER ISOLATED ANALOG CIRCUIT COMMON INTERNAL MODULE CIRCUITRY 1 2 3 4 5 6 7 8 9 10 11 12 18 13 14 15 16 17 24 VDC User Supplied Power Voltage Input Circuits 3 Wire Voltage Transmitter V COM 3 Wire Transmitter 4 Wire Transmitter COM V 4 Wire Voltage Transmitter Transmitter Power Supply AC or DC V7 COM V8 Notes for maximum accuracy 1 Jumper unsused inputs t...

Страница 4: ...an your installation for use of this powerful feature 1 Align with slot 2 rotate to seated position Module Installation WARNING Do not apply field power until the following steps are completed See hot swapping procedure for exceptions WIRESTRIP LENGTH WIRESTRIP LENGTH Step One Align module catch with base slot and rotate module into connector Locked Unlocked Step Two Pull top locking tab toward mo...

Страница 5: ...lected and to each Status Bit Item Wiring Options 1 ZIPLink Feed Through Modules and Cables 0 5 m 1 6 ft cable 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZL RTB20 ZL RTB20 1 ZL P2 CBL18 ZL P2 CBL18 1 ZL P2 CBL18 2 Terminal Block with pigtail cable 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZL P2 CBL18 1P ZL P2 CBL18 2P 3 Screw Terminal Block only P2 RTB Quantity 1 4 Spring Clamp Terminal Block only P2 RTB 1...

Страница 6: ...1 2 3 4 5 6 6 5 7 0 0 0 0 0 0 0 Level Transmitter Tank Level 7 0 0 0 0 0 0 0 Enter values for each breakpoint in the table Each breakpoint will define a segment of the non linear scaling 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 The Scale Linear function can be used to Convert analog field input signals from the range which is native to the analog input module to an application specific range Make other l...

Страница 7: ...7 Sales 800 633 0405 www productivity2000 com ...

Страница 8: ...8 Tech Support 770 844 4200 www productivity2000 com Document Name Edition Revision Date P2 08ADL 2 DS 3rd Ed 8 20 2019 Copyright 2016 AutomationDirect com Incorporated All Rights Reserved Worldwide ...

Отзывы: