8

Tech Support 770-844-4200

www.productivity1000.com

Document Name

Edition/Revision

Date

P1-04DAL-2-DS

1st Edition

9/7/2017

Copyright 2017, AutomationDirect.com Incorporated/All Rights Reserved Worldwide

WARNING:

 

To minimize the risk of potential safety problems, you should 

follow all applicable local and national codes that regulate the installation 

and operation of your equipment. These codes vary from area to area and 

it is your responsibility to determine which codes should be followed, and 

to verify that the equipment, installation, and operation are in compliance 

with the latest revision of these codes.

Equipment damage or serious injury to personnel can result from 

the failure to follow all applicable codes and standards. We do not 

guarantee the products described in this publication are suitable for 

your particular application, nor do we assume any responsibility for your 

product design, installation, or operation.

If you have any questions concerning the installation or operation of 

this equipment, or if you need additional information, please call Technical 

Support at 770-844-4200.

This publication is based on information that was available at the time 

it was printed. At AutomationDirect.com

®

 we constantly strive to improve 

our products and services, so we reserve the right to make changes to 

the products and/or publications at any time without notice and without 

any obligation. This publication may also discuss features that may not be 

available in certain revisions of the product.

8

Tech Support 770-844-4200

www.productivity1000.com

Содержание Productivity 1000 P1-04DAL-2

Страница 1: ...ion 12 bit Resolution Value of LSB least significant bit 0 10 V 2 44 mV count 1 LSB 1 count Data Range 0 4095 counts Output Type Voltage sourcing at 10mA Output Value in Fault Mode 0V Load Impedance 1...

Страница 2: ...rature 20 to 70 C 4 to 158 F Humidity 5 to 95 non condensing Environmental Air No corrosive gases permitted Vibration IEC60068 2 6 Test Fc Shock IEC60068 2 27 Test Ea Field to Logic Side Isolation 180...

Страница 3: ...CH1 DAC CH2 DAC CH3 DAC CH4 DAC CIRCUIT POWER INTERNAL MODULE CIRCUITRY 24V 10 1 2 3 4 5 6 7 8 9 ISOLATED ANALOG ISOLATED ANALOG CIRCUIT COMMON voltage source voltage source voltage source voltage sou...

Страница 4: ...ked position and then pull modules apart Step Two Attach field wiring using the removable terminal block or ZIPLink wiring system WIRE STRIP LENGTH MIN MAX P1 08TD1 UNLOCK LOCK Check all latches are s...

Страница 5: ...ZL RTB20 1 2Terminal Block with pigtail cable 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZL P1 CBL10 1P ZL P1 CBL10 2P 3 Screw Terminal Block only P1 10RTB Quantity 1 4Spring Clamp Terminal Block only P1 1...

Страница 6: ...max The Scale Linear function can be used to Convert an application specific range to range which is native to the analog output module Make other linear conversions in ranges appropriate to the appl...

Страница 7: ...7 Sales 800 633 0405 www productivity1000 com...

Страница 8: ...e failure to follow all applicable codes and standards We do not guarantee the products described in this publication are suitable for your particular application nor do we assume any responsibility f...