Automation Technology C5-2040CS18-38-2X Скачать руководство пользователя страница 5

C5-2040CS18-38-2X Manual Rev. 1.1 

  

  3 

C5-2040CS18-38-2X General Specifications 

 

Sensor Controls

 

Synchronization Modes 

Free Running, Triggered, Software Triggered 

Exposure Modes 

Programmable, Pulse Controlled 

Shutter Modes 

Global Shutter  

Digital Input 

2 electrical isolated inputs, +5V…+24V DC 
VIL, logic “0” Voltage < 1.5V 
VIH, logic “1” Voltage > 3.5V 
Max. frequency: 450 kHz 

Digital Output 

2 electrical isolated outputs, +5V…+24V DC 
VOL, logic “0” Voltage < 0.5V 
VOH, logic “1” Voltage ≥ 3.8V 
IOH, logic “1” drive current max. 100 mA 
IOL, logic “0” drive current max. 100 mA 

Encoder/Resolver Input 

A+,A-, B+,B-, Z+, Z- 
High-Speed Triple RS-422 Receiver 
Max. input v5V DC (TTL signal)  
RS-422-Mode, max. frequency: 15 MHz 

Laser Supply 

Reverse voltage protection 
Supply v5V…+24V DC 
Laser modulation 

Sensor Features

 

High Dynamic Range Imaging 

Multiple Slope, Multi-Frame Readout 

3D-Algorithms 

MAX, TRSH, COG, FIR PEAK 

3D-Scan Features 

Automatic AOI-Tracking, Automatic AOI-Search, 
Multiple AOIs, AutoStart 

Electrical Interface

 

Power Supply 

+10V…+24V DC (max. +27V DC)  

Power Consumption 

6W  

Operating Temperature 

0 °C to +50 °C (non-condensing) 

Output Data Interface 

Gigabit Ethernet (IEEE 802.3) 

Communication Protocol 

GigE Vision with GenICam 

Mechanical Interface

 

Power Connector 

17 pin, M12 connector 

Ethernet Connector 

8 pin, A-coded M12 connector 

Содержание C5-2040CS18-38-2X

Страница 1: ...C5 2040CS18 38 2X User Manual for High Speed Laser 3D Sensors Rev 1 1 AT Automation Technology GmbH...

Страница 2: ...ised in the preparation of this document to ensure that it is fully correct and comprehensive the owners assume no responsibility for errors or omissions Neither is any liability assumed for damages r...

Страница 3: ...Specifications 3 Model Overview with Measurement Specification 5 Mechanical Drawing 6 Housing Type 6 Dimensions 7 Wire assignment for Laser 9 Description of LEDs 10 Master 10 Slave 11 SERVICE INFORMAT...

Страница 4: ...profile measurement by means of laser triangulation technique The 3D profile extraction is performed in the sensor by using high performance Field Programmable Gate Array processors At the same time...

Страница 5: ...r Resolver Input A A B B Z Z High Speed Triple RS 422 Receiver Max input voltage 5V DC TTL signal RS 422 Mode max frequency 15 MHz Laser Supply Reverse voltage protection Supply voltage 5V 24V DC Lase...

Страница 6: ...C5 2040CS18 38 2X Manual Rev 1 1 4 Mechanical Stress Specification Vibration sinusoidal each axis 2 G 20 500Hz IEC 60068 2 6 Shock each axis 15 G IEC 60068 2 27 Enclosure rating IP67 IEC 600529...

Страница 7: ...iew with Measurement Specification Model Name Nominal FOV FOV Near Field FOV Far Field Z Range Working Distance Lateral Resolution Height Resolution Points per Profile Housing Type mm m pixels C5 2040...

Страница 8: ...C5 2040CS18 38 2X Manual Rev 1 1 6 Mechanical Drawing Housing Type Model 5...

Страница 9: ...C5 2040CS18 38 2X Manual Rev 1 1 7 Dimensions Model 5 All dimensions in mm...

Страница 10: ...C5 2040CS18 38 2X Manual Rev 1 1 8 All dimensions in mm...

Страница 11: ...r Male Connector Pin Assignment Pin No Signal Name Description 1 24V 15W 24V Power Supply 3 N C 4 GND Power Supply Ground Cable Pin Assignment Pin Wire No Wire Colour Signal Name Description 1 Brown V...

Страница 12: ...tion of LEDs Master LED Description 1 USR After Power On Off No network cable connected Green On Network connected After Network connected Green On CCP status connected Off CCP status disconnected 2 L...

Страница 13: ...Green On CCP status connected Off CCP status disconnected Red On No network found no network cable connected 3 PWR Green On Power On and camera start up completed Off Power Off or camera start up fail...

Страница 14: ...Fax 49 4531 88011 20 Updates www AutomationTechnology de Service and Support service AutomationTechnology de In order to process your support inquiries immediately we always need the serial number of...

Страница 15: ...stated in its manual Warranty Period The sensors warranty for the C5 CS series is 1 year starting from the date of purchase from AT Automation Technology GmbH Extended Warranty The warranty period can...

Страница 16: ...C5 2040CS18 38 2X Manual Rev 1 1 14 Document Revision Rev No Date Modification 1 0 18 04 2017 First Draft 1 1 07 09 2018 Minor Corrections...

Отзывы: