Connect the probe to the probe cable
 

  Screw the probe together with the cable. For this purpose, always turn only the union nut 

of the cable. A turning movement of the angled cable connection can lead to permanent 
damage of the electrical contacts. This entails the loss of guarantee.

 

  For better probe guidance, insert the probe into the probe holder of the gauge.

The gauge is now ready for use. To remove a probe, follow the above steps in reverse order.

Probe cable

Probe

Probe holder

Содержание QNix 5500

Страница 1: ...QNix 5500 QUALITY MADE IN GERMANY OPERATION MANUAL...

Страница 2: ...ng due to paint and varnish please use diluted solvents ethanol nitro thinner petroleum ether Notice Do not use acetone on soft rubber parts or display Display Use a damp lint free cloth If very dirty...

Страница 3: ...n wijzigingen aan het apparaat aan Repa raties mogen alleen door de fabrikant of een geautoriseerde specialist worden uitgevoerd Pas op Elektromagnetische Ver draagzaamheid Het apparaat kan wor den ge...

Страница 4: ...on 8 4 2 Calibration 8 4 3 Measurement Display 9 4 4 Measure 10 4 5 Substrate Switch 10 4 6 Delete User s Adjustment 11 5 Troubleshooting 11 6 Service and Repair 12 7 Appendix 12 7 1 Gauge Technical D...

Страница 5: ...2 Device Overview Operation Key Battery compartment back Colour display Probe port Probe holder with probe Switch device on or off Reset memory Start adjustment Switch substrate Reset to factory statu...

Страница 6: ...turn the probe input anti clockwise The arrow on the probe holder shows the open padlock on the probe input Pull the probe holder from the input Insert the probe in the probe holder Push the probe in...

Страница 7: ...A turning movement of the angled cable connection can lead to permanent damage of the electrical contacts This entails the loss of guarantee For better probe guidance insert the probe into the probe...

Страница 8: ...different measurement jobs Use a piece of uncoated material being tested or alternatively the included reference plates Start adjustment Press key button briefly Place the gauge either on the referen...

Страница 9: ...Note When the batteries are below 50 a warning screen will appear Press OK to confirm the screen and replace the batteries promptly Probe status bar Probe connected Measurement display n Total number...

Страница 10: ...e the last measurement results from the volatile memory 4 5 Substrate Switch To switch the substrate the gauge has to be held upside down that is the probe shows up Press the button and the gauge swit...

Страница 11: ...he user s adjustment the symbol disappears factory adjustment is now active 5 Troubleshooting If the device is not responding as expected please check the following items Error Possible cause Action D...

Страница 12: ...obert Perthel Strasse 2 50739 Cologne Germany Phone 49 0 221 91 74 55 0 Fax 49 0 221 91 74 55 29 info automation de 7 Appendix 7 1 Gauge Technical Data 7 1 1 Gauge Mechanical Data Mechanical Data Disp...

Страница 13: ...l Data 7 2 1 Probe Mechanical Data Mechanical data Upper housing material Stainless steel 1 4305 Bottom housing material Trogamid CX7323 Test prod material polished ruby Al203 Dimensions length diamet...

Страница 14: ...499 ASTM D 1400 ASTM D 1186 ASTM D 7091 Status indication by RGB LED at the probe Probe type See probe data sheet Measuring range Varies depending on probe type Measuring interval 100 measurements min...

Страница 15: ...15...

Страница 16: ...Automation Dr Nix GmbH Co KG Robert Perthel Str 2 50739 K ln Germany Phone 49 0 221 91 74 55 0 Fax 49 0 221 91 74 55 29 info automation de www q nix com 3 2021...

Отзывы: