Page 3–36
Stellar
®
SR55 Series Soft Starter User Manual – 1st Ed, Rev F – 09/18/2019
Chapter 3: Configuration and Parameters
p
arameTer
d
eTails
– “a
dvanCed
” m
enu
of
p
arameTers
(
ConTinued
)
P8.3 –
Overload Trip
Hold. Reg. Type:
Description:
Read/Write
The overload is an electronic equivalent to a thermal overload.
(See Overload parameter address 33408 for more information about Overload.)
Range:
Modbus Decimal Value: Default (decimal):
• Off : The SR55 will continue to operate regardless of motor
current level.
• On : The SR55 will trip when the “Overload” capacity exceeds
the motor current level chosen in Overload Level and Trip
Class parameters.
• 0
• 1
• On (1)
Modbus Address:
Modbus Format:
53792 ( D220 hex )
16-bit unsigned
Touchscreen Menu Path:
Home → Advanced → Trip Settings → Overload Trip
(also Home → Advanced → Motor Protection → Overload Settings → Overload Trip)
P8.4 –
Low Current Trip
Hold. Reg. Type:
Description:
Read/Write
This can be used to detect if the motor is running lightly loaded.
Range:
Modbus Decimal Value: Default (decimal):
• Off : The SR55 will continue to operate regardless of motor
current.
• On : The SR55 will trip. This feature is not active during soft
start and soft stop.
• 0
• 1
• Off (0)
Modbus Address:
Modbus Format:
53787 ( D21B hex )
16-bit unsigned
Touchscreen Menu Path:
Home → Advanced → Trip Settings → Low Current Trip
(also Home → Advanced → Motor Protection → Low Current Settings → Low Current Trip)
P8.5 –
Start Current Limit Trip
Hold. Reg. Type:
Description:
Read/Write
Selects between trip or continue if the start current limit has been active for too long.
Range:
Modbus Decimal Value: Default (decimal):
• Off : The start will continue regardless of the motor current
level.
• On : The SR55 will trip. This trip is constrained by the Start
Current Limit Level and the Start Current Limit Time.
• 0
• 1
• On (1)
Modbus Address:
Modbus Format:
53790 ( D21E hex )
16-bit unsigned
Touchscreen Menu Path:
Home → Advanced → Trip Settings → Start Current Limit Trip
(Home → Advanced → Start Settings → Start Current Limit → Start Current Limit Trip)
Содержание Stellar SR55 Series
Страница 1: ...Stellar SR55 Soft Starter User Manual SR55_UMW First Edition Revision F...
Страница 2: ...Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 BLANK PAGE...
Страница 6: ...Page W 4 Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 BLANK PAGE...
Страница 8: ...Page H 2 Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 BLANK PAGE...
Страница 14: ...TOC 6 Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 Table of Contents BLANK PAGE...
Страница 148: ...Page 5 22 Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 Chapter 5 Communications BLANK PAGE...
Страница 166: ...Page 6 18 Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 Chapter 6 Accessories BLANK PAGE...
Страница 172: ...Page A 6 Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 Appendix A Updating Firmware BLANK PAGE...
Страница 201: ...Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 BLANK PAGE...