background image

Page 6

DURA

pulse

 GS20 AC Drive Quick-Start Guide – 1st Ed  06/29/2020

DURA

pulse

 GS20 AC Drive Quick-Start Guide

GS20_QSP_1ed 06/29/2020

Environment for Operation, Storage, and Transportation

DO NOT expose the GS20 drive to environments that contain dust, direct sunlight, corrosive/inflammable 

gases, high humidity, liquids, or high vibration.  The salt in the air must be less than 0.01 mg/cm

2

 throughout 

the year.

Envir

onment

Installation Location IEC60364-1/IEC60664-1 Pollution degree 2, Indoor use only
Surrounding 

Temperature

Storage:  -40°C to +85°C

Transportation:  -20°C to +70°C

No condensation, non-frozen

Rated Humidity

Operation:  Max. 90%

Storage/Transportation:  Max. 95%

No condensed water

Air Pressure

Operation/Storage:  86 to 106 kPa

Transportation:  70 to 106 kPa

Pollution Level

IEC60721-3
Operation:  

Class 3C2; Class 3S2

Storage:  

Class 2C2; Class 2S2

Transportation:  

Class 1C2; Class 1S2

No concentrate

Altitude

Operation

If the GS20 drive is installed at altitudes of 0~1000m, follow normal 

operation restriction.  If installed at altitudes of 1000~2000m, decrease 

1% of rated current or lower 0.5°C of temperature for every 100m 

increase in altitude.  Maximum altitude for Corner Grounded is 2000m. 

Contact ADC for more information if you need to use this motor drive at 

an altitude of 2000m or higher.

Package 

Drop

Storage

ISTA procedure 1A (according to weight) IEC60068-2-31

Transportation

Vibration

Operating

1.0mm, peak-to-peak value range from 2Hz to 13.2 Hz; 0.7G~1.0G range from 

13.2Hz to 55Hz; 2.0G range from 55Hz to 512 Hz.  Comply with IEC 60068-2-6.

Non-operating

2.5 G peak, 5Hz~2kHz: 0.015” maximum displacement.

Impact

Operating

IEC/EN60068-2-27: 15G, 11ms

Non-operating

30G

Protection Level

IP40 - main unit

IP20 - wiring area (main circuit terminals and control terminals (all frame types), 

and the vent near the capacitor on frame C, D, E, and F types).

 

To prevent personal injury, please make sure that the case and wiring are installed 
according to these instructions.  The figures in these instructions are only for reference.  
They may be slightly different from the one you have, but it will not affect your 
customer rights.
These installation instructions may be revised without prior notice.  The most recent 
edition can be downloaded from the AutomationDirect web site at any time: 
http://www.automationdirect.com/static/manuals/index.html.

Minimum Mounting Clearances

When installing your GS20 drive, please keep the following in mind:

•  Prevent fiber particles, scraps of paper, shredded wood, saw dust, metal particles, etc., from adhering to the 

heat sink.

•  Install the AC motor drive in a metal cabinet. When installing one drive below another one, use a metal 

separation between the AC motor drives to prevent mutual heating and to prevent the risk of accidental fire.

•  Install the AC motor drive in Pollution Degree 2 environments only: normally only nonconductive pollution 

occurs and temporary conductivity caused by condensation is expected.

 (Blue Arrow) Inflow 

 

 (Red Arrow) Outflow

Single drive Independent installation.

Side-by-side horizontal installation:

Installation Method

(mm)

(mm)

(mm)

Operation Temperature

Max 

(w/out derating)

Max 

(Derating)

Single drive installation

50

30

50

60

Side-by-side horizontal installation

50

30

30

50

60

Zero stack installation

50

30

0

40

50

Содержание DURApulse GS20 Series

Страница 1: ...er supply Drive power to the motor U V W on T1 T2 T3 For use with 3 phase motors only Ground to the motor STO1 and STO2 both must be wired through appropriate N C safety rated contacts to DCM or the f...

Страница 2: ...RNBS 2 3 7 M3 5 9 kg cm 7 8 lb in 0 88 N m Dimension Value Min Max A 9 8 Max B 3 2 Max C 4 8 Min D 4 1 Max d2 3 7 Min E 13 0 Min F 4 2 Min W 6 6 Max t 0 8 Max GS21 20P2 GS23 20P2 18AWG 0 82 mm2 RNBS 1...

Страница 3: ...EV STOP PLC Enable the counter by setting parameter 00 04 to 1 See the user manual for full instructions on using the counter MENU Displays the counter value After selecting the desired menu option pr...

Страница 4: ...0 Parameter Settings Quick Configuration Parameter Description Range Default User Group 00 00 GS20 Model ID Read Only n a 00 01 Displays AC drive rated current Displays value based on model n a 00 02...

Страница 5: ...quency Hz 01 Current A 02 PV P04 12 Analog Output Gain 00 to 200 DURApulse GS2 Parameter Settings Parameter Description Settings User Group P06 31 Present Fault Record 00 No Fault occured 01 Over curr...

Страница 6: ...ith IEC 60068 2 6 Non operating 2 5 G peak 5Hz 2kHz 0 015 maximum displacement Impact Operating IEC EN60068 2 27 15G 11ms Non operating 30G Protection Level IP40 main unit IP20 wiring area main circui...

Страница 7: ...NTING HOLE DETAIL MODELS BY FRAME SIZE FRAME_C1 GS21 11P0 GS21 22P0 GS21 23P0 GS23 23P0 GS23 25P0 GS23 43P0 GS23 45P0 GS23 53P0 GS23 55P0 87 0 3 43 5 5 0 22 5 5 0 22 73 0 2 87 144 5 5 69 157 0 6 18 5...

Страница 8: ...2 0 7 56 NEMA 1 Conduit Boxes The GS20 drives can optionally be fitted to a NEMA1 conduit box with one available box per frame size The dimensional diagrams below show how the box will change the dime...

Отзывы: