Do-more H2 Series PLC User Manual, 1st Edition, Rev. F - H2-DM-M
6–31
Chapter 6: Specifications - Analog I/O Modules
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A
B
C
D
F2-02DA-2(L), Analog Output
One count in the specification table is equal to one least significant
bit of the analog data value (1 in 4096).
Note1: Shields should be connected to the 0V of the module or the OV
of the P/S.
Note 2: Unused voltage outputs should remain open (no connections)
for minimum power consumption.
F2-02DA-2(L) 2-Channel Analog Voltage Output
Number of Channels
2
Output Ranges
0 to 5V, 0 to 10V, ±5V, ±10V
Resolution
12 bit (1 in 4096)
Output Type
Single ended, 1 common
Peak Output Voltage
15VDC
(clamped by transient voltage
suppressor)
Load Impedance
2000
q
minimum
Load Capacitance
0.01 µF maximum
PLC Update Rate
2 channels per scan maximum
Linearity Error
(end to end)
±1 count (0.025% of full scale)
maximum
Conversion Settling Time
5µs maximum (full scale change)
Full Scale Calibration
Error
(not incl. offset error)
±12 counts max. unipolar @ 77ºF
(25ºC)
±16 counts max. bipolar @ 77ºF
(25ºC)
Offset Calibration Error
±3 counts max., unipolar @ 77ºF
(25ºC)
±8 counts max., bipolar @ 77ºF
(25ºC)
Accuracy vs.
Temperature
±50 ppm/ ºC full scale calibration
change
(including maximum offset change of
2 counts)
Maximum Inaccuracy
+0.3% unipolar ranges @ 77ºF (25ºC)
±0.45% unipolar ranges >77ºF (25ºC)
±0.4% bipolar ranges @77ºF (25ºC)
±0.55% bipolar ranges >77ºF (25ºC)
Base Power
Required 5VDC
40mA
External
Power Supply
F2-02DA-2: 18 to 30VDC, 60mA (outputs
fully loaded)
F2-02DA-2L: 10 to 15VDC, 70mA
(outputs fully loaded)
Operating
Temperature
32º to 140ºF (0º to 60ºC)
Storage Temperature
-4º to 158ºF (-20º to 70ºC)
Relative Humidity
5 to 95% (non-condensing)
Environmental Air
No corrosive gases permitted
Vibration
MIL STD 810C 514.2
Shock
MIL STD 810C 516.2
Noise Immunity
NEMA ICS3-304
Terminal Type
(included)
Removable; D2-8IOCON
ZIPLink Module
ZL-RTB20 (Feedthrough)
ZIPLink Cable
ZL-D2-CBL10 (0.5 m)
ZL-D2-CBL10-1 (1.0 m)
ZL-D2-CBL10-2 (2.0 m)
OV
Internal
Module
Wiring
+
--
12 VDC
S ee
Ch 2 load
2K
0 VDC
+12 VDC
N/C
N/C
N/C
N/C
NOTE 1
70mA
CH1--
CH2--
CH1+
CH2+
Voltage sink/source
Transient protected precision
digital to analog converter
output circuits
Ch 1
minimum
Ch 1 load
2K
minimum
Voltage sink/source
Ch 2
DC
to
DC
Co
nv
er
te
r
+5V
+15V
0V
--15V
D to A
Converter
D to A
Converter
Typical user wiring
OV
Internal
Module
Wiring
+
--
24 VDC
Typical User Wiring
S ee
Ch 2 load
2K
0 VDC
+24 VDC
N/C
N/C
N/C
N/C
NOTE 1
60mA
CH1--
CH2--
CH1+
CH2+
Voltage sink/source
Transient protected precision
digital to analog converter
output circuits
Ch 1
minimum
Ch 1 load
2K
minimum
Voltage sink/source
Ch 2
DC
to
DC
Co
nv
er
te
r
+5V
+15V
0V
--15V
D to A
Converter
D to A
Converter
+24V
CH1+
CH2+
NC
NC
0V
CH1–
CH2–
NC
NC
F2-02DA-2
OUT
ANALOG
2CH
F2-02DA-2
18-30VDC
60mA
ANALOG OUT
0-5VDC
-5-+5VDC
0-10VDC
-10-+10VDC
+24V
+
CH1+
+
CH2+
NC
NC
0V
CH1–
CH2–
NC
NC
F2-02DA-2
OUT
ANALOG
A
2CH
F2-02DA-2
18-30VDC
60mA
ANALOG OUT
0-5VDC
-5-+5VDC
0-10VDC
-10-+10VDC