Amplitude Controller 

Model 6005 Series 

OPEN FRAME 

 

MODEL 6005.1 

SUB PANEL MOUNT 

Circuit Board P/N 24-210 

 

Input: 120 VAC, 50/60 HZ. 

Output: 0-120 VAC 

Single Unit Fuse Size:  15 AMPS 
80% Duty Cycle at Rated AMPS 

 

Note: Mount Open Frame controls within an 

enclosure. 

Automation Devices, Inc. 

7050 West Ridge Road 

Fairview, PA  16415-2099 

Phone: 814-474-5561 

              FAX: 814-474-2131  
Web Site: 

WWW.AUTODEV.COM 

E-mail: 

[email protected]

 

 

 

1.  SELECTING OUTPUT PULSE 
MODE 

Choose an output mode of 120 or 60 by sliding the 
OUTPUT  PULSE  DIPswitch  (S1)  to  the 
appropriate position. 

Other names for 

“120 Pulses Per Second” are AC 

or 7200 VPM (Vibrations Per Minute). “60” is the 
same as DC or 3600 VPM or Rectified. 

Note: Readjust MAX pot after changing pulse 
mode setting. 

2.  LIMITING THE MAXIMUM 
OUTPUT OF CONTROL 

Adjust the 

MAX 

Output trimpot so that the output 

to the feeder reaches its desired maximum level 
when the 

MAIN  CONTROL  DIAL 

is turned fully 

clockwise.  The 

MAX 

Output  trimpot  should  be 

adjusted  to  keep  the  vibratory  feeder  from 
hammering  when  the  control  is  turned  up  to  full 
power. 

NOTE:  Output  to  feeder  must  be  connected 
and the control set for proper output frequency 
(60  or  120  pulse)  setting.  The  Run  Jumper 
must  be  connected  as  shown  on  the  wiring 
diagram. 

A.  Power input should be 

OFF 

or disconnected. 

B.  Rotate 

MAIN CONTROL DIAL 

on front cover 

to 0 or its minimum setting. 

C.  Open cover to allow access to printed circuit 

card. 

D.  Using 

CAUTION

, turn power 

ON 

(no output 

should be present). 

E.  Rotate  the 

MAIN  CONTROL  DIAL 

on  front 

cover slowly to its highest setting. 

F.  Adjust  the 

MAX 

output  trimpot  so  that  the 

output  to  the  feeder  reaches  its  desired 
maximum  level  when  the 

MAIN  CONTROL 

DIAL 

is  turned  fully  clockwise.  Turning  the 

MAX 

output trimpot clockwise increases the 

maximum output level. 

3.  REMOTE OFF/ON CONTROL 

A Run Jumper has been installed at the factory as 
shown on the enclosed wiring diagram. 

Note:  TB2 terminals 5-7 are referenced to the line 
voltage  circuit.  Therefore  any  switch  or  contact 
connected  to  them  must  be  isolated  from  other 
circuits. 
Remote OFF/ON operation of the control can be 
configured to operate in one of the following ways. 

A.  A low current switch such as a paddle switch 

can replace the factory-installed Run Jumper 
"J1."  The  "Run  Contact"  connects  across 
terminals 6 and 7. The contact must be able to 
switch 5VDC and 2mA. The control will then 
run only when the contact is closed. Refer to 
Section A of the OFF/ON CONTROL GUIDE. 

B. Feeder  Bowl/Hopper  Interlock  allows  the 

Hopper control to operate only when the Bowl 
is  running  and  the  paddle  switch  contact  is 
closed. The 

interlock input 

on terminals 11 

and 12 of TB2 is controlled by the 

interlock 

output 

of  a 

“Parts  Sensing  Feeder  Bowl 

Control” such as a 6800 Series control. 

Remove  jumper  "J1"  of  this  control  from 
terminals  6  and  7.  Connect  the  Hopper 
Paddle switch to alternate terminals 5 and 6. 
Connect  TB2  terminals  11  and  12  of  this 
control to the "Parts Sensing Control". Refer 
to  Section  B  of  the  OFF/ON  CONTROL 
GUIDE.  Check  specific  instructions  for  the 
"Parts Sensing Control" wiring. 

Note:  Two  6040  Series  controls  will  not 
interlock to each other since neither one has 
an 

interlock output

C.  Low  Voltage  DC  can  be  used  to  turn  the 
control 

ON 

and 

OFF. 

Move  jumper  "J1"  from 

terminal  7,  to  terminal  5,  (6  remains  the  same). 
Then connect the positive signal (+10 to 30VDC @ 
10mA) to terminal 12 and the negative to terminal 
11 of TB2.  The control will now turn 

ON 

when the 

DC  signal  is  present  at  terminals  11  and  12  of 
TB2. This  input  is  optically  isolated.  Refer  to  Sect. 
C  of  the  OFF/ON  CONTROL  GUIDE.  TB-2 
terminals 5-7 are transformer isolated from the line 
voltage circuit. 

ADI 6005.1 24-210 120921.doc 

Page 1 

 ADJUSTMENTS 

AND SET UP

 