Coal-trol Digital™ – Model TS2 THERMOSTAT

Automation Correct LLC

6/2006 R0

www.automationcorrect.com

Page 5

Instruction Manual

Locating the Thermostat

The room temperature sensor is located in the Thermostat. For proper operation, the sensor must 
be exposed to the heat produced by the stove. The preferred mounting locations include: on an 
inside wall, away from the direct air stream of the convection blower, and away from radiant heat 
produced by the stove. Note that the Thermostat does not have to be within the same room as the 
stove.  For  example,  a  coal  furnace  ducted  to  the  return  air  plenum  of  an  oil  or  gas  furnace  will 
give good results if the Thermostat is mounted next to the oil/gas furnace thermostat.

25 ft. Thermostat Cord

Connect Thermostat to Control Module

The  provided  25ft.  cord  may  be  extended  with  an  8 
pin, RJ45 to RJ45 coupler and/or standard computer 
network  cable.  The  cable  must  be  a  'through'  type, 
not a crossover type. Note: The Coal-trol thermostat 
and Power Module cannot be connected to computer 
networks through this cable.

Connect  the  Thermostat  cable  to  the  THERMOSTAT  connector  on  the  Control  Module  and  the 
Connector on the rear of the TS2 Thermostat.

HiTemp    

Room Over-Temperature Cutout

The  STATUS  indicator  light 
blinks every second.

The  temperature  sensor  in  the 
thermostat  has  detected  a 
room  temperature  above  98°F/
37°C  and  has  disabled  the 
Stoker  motor,  combustion  air 
motor  and  the  Convection 
Blower.  If  installed,  the  Power 
Vent motor continues to run.

DISPLAY

ACTION

NOTE

STOP

CAUTION:  Before  proceeding, 
investigate  the  cause  of  the 
over-temperature condition.

The  HI  TEMP  display  may 
indicate  a  problem  with  your 
stove,  chimney,  or  Coal-trol 
Digital System. 

Press MENU button to Reset.

The  thermostat  will  not  allow 
the  MENU  button  to  reset  the 
thermostat  until  the  room 
temperature  is  less  than  97°F/
35°C

Содержание Coal-trol Digital TS2

Страница 1: ...ith a PB1 CM1 or CM2 control modules Refer to the Installation manual for your control module for other information not found here Introduction Table of Contents Welcome Coal trol Digital Feature Overview 2 Safety Information 3 For Service and Repair 4 Coal trol Digital Limited Warranty 4 Locating the Thermostat 5 Connecting Control Module and Thermostat 5 Room Over Temperature Cutout 5 Operating ...

Страница 2: ...d air furnace located in the basement with the thermostat mounted upstairs can work fine Fuel feed is continuously adjusted to maintain room temperature as set on the Coal trol thermostat The Convection blower is automatically started and continuously adjusted to match the heat output of the stove Two temperature setbacks automatically change the temperature at prescribed times set by the user on ...

Страница 3: ...ove furnace is built in compliance with these safety standards THIS PRODUCT HAS A GROUNDING TYPE PLUG AND REQUIRES A GROUNDING TYPE OUTLET IF THE PLUG DOES NOT FIT CONTACT A QUALIFIED ELECTRICIAN DO NOT MODIFY THE PLUG IN ANY WAY TOREDUCERISK OF ELECTRICAL SHOCK DONOT CONNECT TO A CIRCUIT OPERATING AT MORE THAN 150 VOLTS TOGROUND WARNING The Coal trol Digital is capable of regulating a coal fire s...

Страница 4: ...antability and fitness for a particular purpose are hereby limited in duration to the period for which the LIMITED WARRANTY is given and applies Some states do not allow limitations on how long an implied warranty lasts so the above may not apply to you The expressed warranties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor dealer or other person ...

Страница 5: ...n 8 pin RJ45 to RJ45 coupler and or standard computer network cable The cable must be a through type not a crossover type Note The Coal trol thermostat and Power Module cannot be connected to computer networks through this cable Connect the Thermostat cable to the THERMOSTAT connector on the Control Module and the Connector on the rear of the TS2 Thermostat HiTemp Room Over Temperature Cutout The ...

Страница 6: ...re condition This LED also blinks when in TEST mode or when Coal trol is initially power on UP button each press will increase a setting Press and hold to increase fast Also used to enter SETUP menu settings DOWN button each press will decrease a setting Press and hold to decrease fast Also used to enter SETUP menu settings MENU button each press will display next setting Pressing and holding will...

Страница 7: ...rrent Time 1126A Current Temperature Starting from the Round Robin display each press of the MENU button will sequence through the displays below SETUP See Setup Menu Operations and Extended Menu Operations for more information MENU button DISPLAY ACTION NOTE MENU button Nighttime Temperature setting Time of Nighttime Temperature setting See Night Temperature Setting for instruction on adjusting s...

Страница 8: ...he time when the Daytime Temperature setting will occur Press MENU key until display shows Daytime Time setting D on left of display D 70F Press UP DOWN buttons to set desired daytime temperature setting When finished press MENU button MENU button UP DOWN button D 68F Press UP DOWN buttons to set desired daytime temperature setting When finished press MENU button UP DOWN button In this example at ...

Страница 9: ...ton MENU button UP DOWN button N 63F New nighttime temperature setting When finished press MENU button UP DOWN button In this example at 11 30 PM the thermostat will set the temperature to 63 F H 72f Press UP DOWN buttons to change temperature setting The new temperature setting remains in effect until the time for the next programmed daytime or nighttime temperature setting H 65F Hold Temperature...

Страница 10: ...cannot be decreased below the MIN feed value The SETUP menu is for initial setup and advanced features Under normal operation these setting need not be adjusted TBRN Y Temperature Units UP button DOWN button Set to Y for Tri burner type feeders otherwise set to N SETUP is displayed for only 1 second MENU button S 1154A SET Time of Day Clock Value Press UP or DOWN button to adjust Display shows A f...

Страница 11: ...tes that the stoker motor is currently pushing fuel Continued from previous page MENU button From bottom of previous page 6 Harman N 99 12 00P F N 0 VALUE 0 Y 99 N 12 00P F Tri burner Reading 45 VALUE VALUE N 12 00P 4 F N 40 0 Alaska N 75 F 12 00P VALUE 0 N 10 Keystoker VALUE N 12 00P F 6 0 N Leisure Line 40 Factory SETUP ITEM VALUE S 12 00P IGN N HLF 0 TBRN N 40 MAX MIN 4 F DEG SETUP Menu Factory...

Страница 12: ... button for 5 seconds The display counts down from 10 once a minute until complete FEED 10 9 8 1 When complete the thermostat will revert to the Round robin display FEED UP or DOWN button TEST Menu button MENU button STOKER CMBSTN CNVCTN IGNITR AUXFAN V2 016 IC 000 UP or DOWN button In turn each control item is turned on for 5 seconds until MENU button is pressed Stoker Motor Combustion Fan Convec...

Страница 13: ...Coal trol Digital Model TS2 THERMOSTAT Automation Correct LLC 6 2006 R0 www automationcorrect com Page 13 Instruction Manual THIS PAGE INTENTIALLY BLANK ...

Страница 14: ... 45Kg Storage Temperature 40 F to 120 F 98 F 35 C Software Temperature Shutdown Limited Operating Temperature Mechanical Construction ABS Plastic UL94V 0 5 367 L x 2 5 8 W x 1 260 H 13 63 cm L x 6 68 cm W x 3 2 cm With mounting bracket Dimensions Electrical Note Automation Correct LLC is constantly working to improve our products For this reason all specifications are subject to change without not...

Страница 15: ...Coal trol Digital Model TS2 THERMOSTAT Automation Correct LLC 6 2006 R0 www automationcorrect com Page 15 Instruction Manual THIS PAGE INTENTIALLY BLANK ...

Страница 16: ...trol Digital Pelli stat by Automation Correct LLC All others trademarks by the respective owners Syracuse NY www automationcorrect com Automation Correct LLC designs and manufactures technology products for home and industry Combining over 75 years of practical experience the Engineers and Technicians of Automation Correct LLC are dedicated to supporting our customers with innovative products ...

Отзывы: