Automation Correct Coal-trol Digital TS2 V3 Скачать руководство пользователя страница 1

Coal-trol Digital™ - Model TS2 V3

Automation Correct LLC

5/2010 R0

www.automationcorrect.com

Page 1

Instruction Manual

To  a  new  era  in  solid  fuel  heating.  You  have  chosen  to  improve  your 
household comfort and increase the efficiency of your heating dollars.

The Coal-trol Digital™ system has been specifically developed to improve 
the performance and convenience of your anthracite coal stove. A new type 
of digital thermostat and solid-state control module make this possible.

An investment of a small amount of time to review this manual will ensure 
proper performance of your Coal-Trol Digital™ system.

This  manual  contains  operating  instructions  for  the  Coal-trol  Digital™ 
Model TS2 Thermostat when used with a model CM2 Control Module. This 
equipment has been factory supplied by your stove manufacturer.

Introduction

Table of Contents

Welcome –

Coal-trol Digital Feature Overview

2

Safety Information

3

For Service and Repair

4

Coal-trol Digital Limited Warranty

4

Locating the Thermostat

5

Connecting Control Module and Thermostat

5

Power ON/OFF Switch

5

Operating Controls of the Thermostat

6

Quick Usage Guide

7

Power-up Sequence

8

MENU Button Operation

8

Round-robin Temperature/Time Display

9

Override Temperature Setting (Setback Override)

9

Fan Speed Control

9

Firing Rate Indicator

9

Day & Night Temperature Setting (Setbacks)

10

SETUP Menu Operation

11

MIN/MAX Adjustment and Factory Settings

12

EXTENDED Menu Operation

13

Overtemperature and Maintenance

14

Specifications

15

Copyright 2004-2008 Automation Correct LLC. All rights reserved.

Coal-trol Digital™, Pelli-stat™ by Automation Correct LLC

All others trademarks by the respective owners.

Page

SYRACUSE • NY

Содержание Coal-trol Digital TS2 V3

Страница 1: ...le This equipment has been factory supplied by your stove manufacturer Introduction Table of Contents Welcome Coal trol Digital Feature Overview 2 Safety Information 3 For Service and Repair 4 Coal tr...

Страница 2: ...o the thermostat Fuel feed is continuously adjusted to maintain room temperature as set on the Coal trol thermostat The convection blower is automatically started and speed adjusted according to amoun...

Страница 3: ...ce with these safety standards THIS PRODUCT HAS A GROUNDING TYPE PLUG AND REQUIRES A GROUNDING TYPE OUTLET IF THE PLUG DOES NOT FIT CONTACT A QUALIFIED ELECTRICIAN DO NOT MODIFY THE PLUG IN ANY WAY WA...

Страница 4: ...including implied warranties of merchantability and fitness for a particular purpose are hereby limited in duration to the period for which the LIMITED WARRANTY is given and applies Some states do not...

Страница 5: ...cable The cable must be a through type not a crossover type Note The Coal trol thermostat and Power Module cannot be connected to computer networks through this cable Connect the Thermostat cable to t...

Страница 6: ...tting or over temperature condition UP button Each press will increase a setting Press and hold to increase fast Also used to enable a selected setting DOWN button Each press will decrease a setting P...

Страница 7: ...splay will show FSA Press the UP or DOWN buttons to adjust convection blower speed as desired Setting the speed to 0 will return the blower to automatic Change the temperature setting for awhile Set t...

Страница 8: ...d or pressed and held for 2 seconds or pressed and held for 5 seconds Display changes to Power up Sequence Upon first power to the thermostat the display will momentarily show the firmware version num...

Страница 9: ...the Current Time Fr 13 If the display shows a plus sign this indicates that the stoker motor is currently feeding fuel Firing Rate Indicator Automatic or Manual control of the room air blower FSM 38 D...

Страница 10: ...Daytime Temperature setting will occur D 700A UP DOWN button D 70F D 68F DOWN button UP button MENU button NOTE Press MENU key once Night Temperature Setting Nighttime Setback In this example at 11 3...

Страница 11: ...thermostat The word SETUP is displayed for only 1 second and then the display shows the Time of Day setting S12 00P Display shows S for SET After extended power loss the time of day setting may be ad...

Страница 12: ...will not be solved by MIN MAX adjustment While displaying MIN or MAX the Coal trol Digital runs the stoker at the MIN or MAX value and NOT according to desired room temperature When finished making a...

Страница 13: ...s are connected correctly and to determine if they are working Stoker Motor Combustion Fan Convection Blower Igniter Auxiliary Fan Ignition Counter MENU button IGNITE MENU button Brnout MENU button ME...

Страница 14: ...termine the source of an electrical or mechanical problem is to go to TEST mode and observe for proper operation of the controlled item 1 No power to Control Module 2 Cable not snapped in 3 Bad cable...

Страница 15: ...0 3 cm x 5 2 cm Dimensions Environmental Weight PB1 CM1 Approx 3 5lbs 1 59Kg Storage Temperature 40 F to 120 F 113 F 45 C MAX Operating Temperature FOR INDOOR USE ONLY Environmental Weight Less than 1...

Страница 16: ...Digital Pelli stat by Automation Correct LLC All others trademarks by the respective owners Syracuse NY www automationcorrect com Automation Correct LLC designs and manufactures technology products fo...

Отзывы: