Setting safety obstruction force

8. Safety obstruction test

Please take care when testing the Safety 
Obstruction Force. Due to Excessive forces 
failure to follow this warning may cause SERIOUS 
PERSONAL INJURY and/or property damage. The 
test below should be repeated at regular intervals 
(approximately every two months).

8.1 Testing close cycle

1. Open the door by pressing the OPERATE button 

(Fig. 12).

2. Place a length of timber approximately 50mm high 

on the fl oor directly under the door 

(Fig. 13).

3. Press the OPERATE button to close door. The door 

should strike the object and start to re-open.

NOTE: 

If the door stops and fails to reopen, it is possible 

that the motor direction is set incorrectly. Change the 
motor direction and retest.

IMPORTANT WARNING: If the test fails, there 

may be a problem with the door, discontinue 

use, put the door into manual operation and 

call for service.

8.2 Testing open cycle

1. With the door closed - press the OPERATE button. 

to open the door. When the door is approximately 
one metre above the hold the bottom rail of the 
door fi rmly, the door should stop.

Adjusting safety obstruction force

The Safety Obstruction Force is calculated automatically 
and set in memory on the EasyRoller®. It is usually not 
necessary to adjust the Safety Obstruction Force. The 
only time the force may need to be increased is due to 
environmental conditions, for example, windy or dusty 
areas, and areas with extreme temperature changes. If 
adjustments are made you must retest the obstruction 
force margin as per above.

8.3 To increase force pressure

1. Press and hold the Force Margin Set button 

(Fig. 12)

2. While holding down the Force Margin button, press 

the Plus button. Each press increases the force 
margin in both directions. The Open Limit LED will 
illuminate each time the Plus button is pressed. Each 
press increases the force margin. Test the force as 
per step 8.1 and 8.2. If the Open Limit LED fl ashes 
continuously when the Plus button is being pressed, 
this indicates that the maximum force pressure 
setting has being reached.

8.4 To decrease force pressure

1. Press and hold the Force Margin Set button 

(Fig. 12).

2. While holding down the Force Margin button, press 

the Minus button. Each press decreases the force 

12

fi g

13

fi g

margin. The Close Limit LED will illuminate 
each time the Minus button is pressed. Test 
the force as per step 8.1 and 8.2. If the Close 
Limit LED fl ashes continuously when the Minus 
button is being pressed, this indicates that 
the maximum force pressure setting has been 
reached.

8.5 To recall factory set force

1. While holding down the Force Margin Set 

button 

(Fig. 12)

 press the SET button for 

two (2) seconds.

2. Release both buttons. The default setting 

should now be recalled.

8.6. To re-calculate force margin (iss)

Press and hold the Set Button for two (2) seconds, 
the beeper will sound once. The door will start to 
move and re-calculate force margins. The door can 
move between the open and close limit positions 
up to four (4) times (depending on the position of 
the door and the power up condition). A single 
beep will be heard once the process is complete. 
The door is now ready for use.

IMPORTANT NOTE: 

After installation ensure 

that the opener stops or is prevented from 
opening when the door is loaded with a mass 
of 20kg fi xed centrally at the bottom edge of 
the door.

Wood (50mm high)

Содержание GDO-8V2 EasyRoller II

Страница 1: ...GDO 8V2 EasyRoller II INSTALLATION INSTRUCTIONS OWNERS COPY Weather Resistant Roll Up Door Opener PN13240 ...

Страница 2: ...uch may be lawfully excluded hereby expressly disclaims all conditions or warranties statutory or otherwise which may be implied by laws as conditions or warranties of purchase of an Automatic Technology Australia Pty Ltd Roll Up Garage Door Opener Automatic Technology Australia Pty Ltd hereby further expressly excludes all or any liability for any injury damage cost expense or claim whatsoever su...

Страница 3: ...Setting Obstruction Force Margin ISS 15 Re Calculating Force Margin Sensitivity 15 Coding Transmitters 16 Deleting Transmitters 16 Locking the Control Panel 16 Connecting Photo Electric Beam 17 Connecting External Secure Light Module 17 Using Manual Release 17 Resetting Factory Defaults 17 Door Status Indicators 18 Buttons and Functions 18 Supplier Installer Information 18 Factory Default Settings...

Страница 4: ...perty damage can result from failure to follow this warning DO NOT allow children to operate the EasyRoller II Serious personal injury and or property damage can result from failure to follow this warning Regularly check to make sure that the safety obstruction force is working correctly and is tested and set as per page 15 of this Manual Failure to follow this could result in serious personal inj...

Страница 5: ...tallation or an incorrectly balanced door may cause injury DO NOT attempt to repair the door yourself as hardware is under extreme tension Remove or disengage all garage door locks and mechanisms prior to installation of the EasyRoller II Connect the EasyRoller II to a properly earthed general purpose 240V mains power outlet installed by a qualified electrical contractor The outlet and EasyRoller I...

Страница 6: ...LPS Automatic Limits Positioning System The ALPS system automatically calculates the door s travel limits and stores it in memory If the door is moved manually within the travel limits during a power failure the ALPS will recognise this once the power is restored and stop at the correct limit position if the door is activated During installation the hand held transmitter can be programmed to set t...

Страница 7: ... P E beam to be connected for extra safety protection Secure Light Module optional external secure light module is available to connect to the gdo8 opener light stays on for approximatly four minutes after the operation of opener Manual operation The opener is equipped with a unique patented manual disengaging device If the power to the opener is disrupted for any reason the door can be put into m...

Страница 8: ...e Force Margin Set is only ever used if other environmental factors wind etc affect the operations of the door opener Plus button green for limits setting and force margin can be used during installation to set the open limit position Pressing this button will move the door in the open direction Movement stops when the button is released NOTE The open safety obstruction detection is inoperable whe...

Страница 9: ...Owner Installation Instructions GDO 8V2 EasyRoller II 9 01 02 03 04 05 06 07 08 09 10 11 12 14 15 13 Operating controls ...

Страница 10: ...ad screw M4x50mm not included in some models 2 Nilock hex nut M4 not included in some models 2 Flat washer I D 3 16 x not included in some models 2 Locking bar covers 2 Installation manual 1 Pan head screw M4x50 Securacode PTX 4 Alkaline battery A23 12V Locking bar covers Saddle Drive unit Weight bar Door drum Hex nut Nilock nut M4 Washer 3 16 x Reinforcement plate Flat washer Spring washer Nuts B...

Страница 11: ...lb Make sure that all door locks ropes chains etc are either released or disabled and remove unnecessary accessories 2 Fixing Of Door Weight Bar Move the door manually to the half open position Place the weight bar on the bottom rail in the middle of the door and secure with the fasteners provided Fig 02 Check the operation of the door again If the door feels heavy it may require extra tension to ...

Страница 12: ...ket from wall 6 Remove the drive assembly from the packaging Try to rotate the drive gear by pushing on the fork If the gear does not rotate the manual mode has to be selected To select pull downward on the string handle then release slowly The drive gear should now rotate freely 7 Slide the drive assembly over the door axle making sure that the fork extends into and over one of the spokes of the ...

Страница 13: ... until the open and close limits positions are set 6 1 Coding transmitter for setting limits 1 Press and hold the Door Code button Fig 09 2 Press button 1 Fig 11 on the transmitter for two seconds 3 Release and pause for two seconds 4 Press the same button transmitter again for two seconds 5 Release the Door Code button 6 2 Setting datum position 1 Switch the opener into manual mode Fig 08 2 Move ...

Страница 14: ... to your desired closed position IMPORTANT WARNING Please be aware that the garage door will start closing automatically once step 8 is performed The door will also automatically re open after fully closing with a short pause between the cycles 8 Once you are happy with the position press button 2 to store the open limit position into memory The door will now automatically close to its limit posit...

Страница 15: ... To increase force pressure 1 Press and hold the Force Margin Set button Fig 12 2 While holding down the Force Margin button press the Plus button Each press increases the force margin in both directions The Open Limit LED will illuminate each time the Plus button is pressed Each press increases the force margin Test the force as per step 8 1 and 8 2 If the Open Limit LED flashes continuously when ...

Страница 16: ... seconds the button should now be stored 5 Wait for 10 seconds and then test the new transmitter to see if it operates the door 11 Deleting programmed codes 11 1 deleting a stored transmitter code 1 Select the transmitter you want to delete 2 Press and hold the Door Code button Fig 14 3 Press the transmitter button you would like to delete for two seconds Pause for two seconds Press the transmitte...

Страница 17: ...ch the opener to manual mode simply pull the red manual release handle down and release To re engage the opener repeat the above action Fig 18 Note The door may move uncontrollably if the spring tension is weak or not set properly or the door is unbalanced If this occurs do not use the door and contact your installer for service The manual release handle can be locked to prevent unwanted disengage...

Страница 18: ...oor code Codes a transmitter button for OPERATE function Force Margin Set plus Increases the obstruction force margin setting Force Margin Set Minus Decreases the obstruction force margin setting Force Margin Set then Set Reloads the factory set default obstruction force margin setting Close for 6 seconds Clears the door limits set positions Limits then need to be reset Set then power on hold unti...

Страница 19: ... type UHF 433 92 MHz am receiver Receiver code storage capacity 8 x 4 button transmitter codes Transmitter frequency 433 92 MHz Coding type Code hopping No of code combinations Over 4 29 billion random codes Code generation Non linear encryption algorithm PTX 4 transmitter battery A23 Alkaline 12V NOTE 1 The maximum continuos curtain residential roll up door opening that the EasyRoller can be inst...

Страница 20: ...or close fully Door limits position need to be reset Door limits position need to be reset See Page 14 Door is overshooting or not reaching limits Datum position not set correctly Reset datum position See Step 6 2 Page 13 Cannot set limits Datum position not set correctly Reset datum position See Step 6 2 Page 13 Door not working with PE installed PE Beam or wiring faulty PE Beam not aligned corre...

Страница 21: ...s such as cordless telephones wireless stereo headphones and baby monitors It is possible that these devices could cause a degree of interference such as to greatly reduce the range of the transmitter In such an instance please contact your Automatic Technology dealer for an alternative frequency replacement kit As this is not a warrantable situation but an environmental issue charges may apply fo...

Страница 22: ...an head screw w washer M4x8 10320 18 Taptite screw P black znc M3x14 10552 19 Internal tooth lock washer I D 3 11150 20 Cable tie 4 GT 100M 14160 21 String handle assy 01762 22 Control board CB 17 01010 23A Chassis enclosure assy 02851 23B Chassis enclosure LK AY with lock 02853 24 Control cover assy 03212 25 Industrial saddle 03175 26 U bolt M8 10141 27 Hex serration fl ange nut M8 black 10148 28 ...

Страница 23: ... manual m attempted or complete modification or repairs to the product carried out by a person who is not authorised or has not been trained by ATA to carry out such modification or repairs n faulty or unsuitable wiring of structure to which the product is fixed or connected o radio including citizen band transmission or any electrical interference p damage caused by insects q loss or damage to any p...

Страница 24: ...GATE OPENERS REMOTE CONTROL ACCESS SOLUTIONS Automatic Technology Pty Ltd ABN 11 007 125 368 6 8 Fiveways Boulevard Keysborough Victoria 3173 P 1300 133 944 E sales ata aust com au www ata aust com au ATA110906GDO 8v2 DBK ...

Отзывы: