Axess® Pro Series 1101
Owner Installation Instructions
Activity report ID
This parameter sets the ID of the controller that
is sent with the activity report. Contact Automatic
Technology for more details.
Vacation mode
Vacation mode can be turned on or off using this
parameter.
Password protection
The password feature enables all parameters and
confi guration settings to be protected unless a
password is entered. When this feature is turned
on the user is requested to enter the desired
password to be used. The password protection
feature has a time-out that expires after 60
seconds of inactivity. Alternatively the user may
log out manually by pressing exit when the main
screen is displayed.
Transmitter grouping
The transmitter store number display format can be
changed to show a grouped format. When grouping
is selected, instead of displaying the store location as
a number between 1 and 511, it is displayed as ##$
where ## is the group number and $ is a character
a,b,c,d,e,f,g or h which indicates the group member.
Open input polarity
The OPN input is normally confi gured for N/O
operation. This parameter allows its operation to be
changed to N/C.
Stop input polarity
The STP input is normally confi gured for N/O
operation. This parameter allows its operation to be
changed to N/C.
Open input as second PE BEAM input
The open input can be confi gured to use as a second
normally open PE beam input.
Parameter
Min
Max
Default
Step
Unit
Menu No.
P.E INPUT RESPONSE MODE Sets the P.E
response mode. Options are OPEN and CLOSE
cycles stop, Close cycles stop or Close cycle
reverse
CLS to
reverse
7.1
PED INPUT = SWIPE MODE Selects PED input
functions as pedestrian access swipe input
Off On
Off
7.2
REMOTE CODE ENABLED
Selects remote transmitter coding function
Off On
Off
7.3
ACTIVITY REPORTS Select report to be output
Off
255
Off
1
7.4
ACTIVITY REPORT ID
Selects ID for controller, sent with activity report
0
65535
0
1
7.5
VACATION MODE
Selects vacation mode - disables remote control
Off On
Off
7.6
PASSWORD
Selects password protection for all changes
Off On
Off
7.7
TX # GROUPING
Selects tx’er number group display format
Off On
Off
7.8
OPN INPUT N/C OPERATION
Selects operating polarity of OPN input
Off On
Off
7.9
STP INPUT N/C OPERATION
Selects operating polarity of STP input
Off
On
Off
7.10
OPN INPUT 2nd P.E OPERATION
Selects OPN input as 2nd P.E input
Off
On
Off
7.11