background image

 

 

AUTOMATIC TECHNOLOGY AUSTRALIA PTY LTD 

 

ROLL UP GARAGE DOOR OPENER 

OWNERS COPY 

Installation Instructions 

And Owners Manual 

Warning: Failure to comply with the  

Installation instructions and the  

Safety warnings may result in  

Serious Personal injury and/or Property and  

 Remote Control Opener damage. 

Re

mote

  

contr

ol 

Содержание ROLL UP GARAGE DOOR OPENER

Страница 1: ...DOOR OPENER OWNERS COPY Installation Instructions And Owners Manual Warning Failure to comply with the Installation instructions and the Safety warnings may result in Serious Personal injury and or Pr...

Страница 2: ...result from failure to follow this warning Make sure that the SAFETY OBSTRUCTION FORCE is working correctly and is TESTED and set as per the Installation Instructions Manual Failure to follow the Man...

Страница 3: ...table It is compulsory to in stall a Photo Electric Beam if this mode is selected otherwise the door will not operate SAFETY AUTO RUN TIME If the Opener does not complete its cycle within thirty secon...

Страница 4: ...onnected to the Opener by wire cable The monitor indicates the status of the door for example if the door is moving or is opened or closed etc The door can also be controlled from the monitor unit 18...

Страница 5: ...DJUST SCREW GREEN 13 CLOSE LIMIT ADJUST SCREW RED 14 OPEN LIMIT CAM GREEN 15 CLOSE LIMIT CAM RED OPERATING CONTROLS 5 1 FORCE MARGIN SET BUTTON 2 OPEN LIMIT LED GREEN 3 OPEN DRIVE BUTTON GREEN 4 O S C...

Страница 6: ...KEY RING TRANSMITTER PTX 4 2 3 1 ALKALINE BATTERY A23 12V 2 4 WEIGHT BARS NOT INCLUDED IN SOME COUNTRIES 2 5 WEIGHT BARS ACCESSORY PACK NOT INCLUDED IN SOME COUNTRIES 1 5 1 PAN HEAD SCREW M5x40 4 5 2...

Страница 7: ...The door must be well balanced and be in an reasonable oper ating condition You should be able to lift the door smoothly and with little resistance It should stay open around 900mm to 1200mm above the...

Страница 8: ...t diffuser and fix the top screw not supplied through the control box see Fig 3 Replace the light dif fuser 4 LEFT OR RIGHT HAND INSTALLATION The Automatic Opener can be installed on the left or right...

Страница 9: ...Carefully loosen and remove the right hand door shaft U bolt 5 Make sure that the door supporting prop is secure While the door is supported remove the right hand door mounting bracket from wall 6 Rem...

Страница 10: ...ockwise direction the green limit cam Fig 11 until the cam clicks the open limit switch 3 Move the door down by hand to the desired closed position 4 Rotate by hand in a clockwise direction the red li...

Страница 11: ...equal to approximately 10 mm of door travel NOTE If the door has not reached the desired limit position by more then 30 mm then it is recommended that the red limits cam be adjusted again before the...

Страница 12: ...en 30 mm it is recommended that the green limits cam be adjusted again before the green fine adjustment screw is adjusted CLOSE LIMIT ADJUSTMENT Press in and hold the Red Close button Fig 15 The door...

Страница 13: ...ressure you can change it as below 8 2 TO INCREASE FORCE PRESSURE 1 Press and hold the Force Margin Set button 1 Fig 16 2 While holding down button 1 press the green Open button 3 The green LED will i...

Страница 14: ...ING THE TRANSMITTERS CODE 1 Press and hold the blue Door Code button on the Control Panel button 9 FIG 18 2 Press the button one of four on the Transmitter you would like to use to control the door fo...

Страница 15: ...uld not respond 11 2 DELETING ALL STORED TRANSMITTER CODES 1 Turn the Power Off to the Drive Unit 2 Press and hold the blue Door Code button 9 Fig 21 on the Control panel 3 Turn the Power On again whi...

Страница 16: ...o close time has been set If the P E path is not broken the door will remain open till the path is broken If the Door Opener in curs an obstruction not from the P E while closing the door will re open...

Страница 17: ...OPENING FLASHING CLOSING FLASHING DOOR TRAVEL STOPPED FLASHING FLASHING DOOR OBSTRUCTED WHEN OPENING FLASHING BEEPS ON AND OFF DOOR OBSTRUCTED WHEN CLOSING FLASHING BEEPS ON AND OFF DOOR OVERLOADED F...

Страница 18: ...18 SPARE PARTS WHEN ORDERING SPARE PARTS QUOTE THE ORDER CODE NUM BER TO YOUR LOCAL IN...

Страница 19: ...ion step 7 and 8 Lights malfunction or keep blowing Globe blown or incorrect globe Replace with 24V DC 15 watts Festoon globe Courtesy Light Flashing The Door Opener has detected a overload condition...

Страница 20: ...ich arise out of a accidental damage to or normal wear and tear to the Product or to the Product s components b flood fire or lighting c incorrect improper or unreasonable maintenance and or use d ins...

Отзывы: