Additional Safety 

Instructions for welders 

Welders have many sources of danger. It 
is therefore particularly important for the 
welder to comply with the following rules 
so as not to place themselves or others in 
danger and to avoid endangering people 
and equipment. 

a) Have all work on the mains voltage
system, for example on cables, plugs,
sockets, etc., performed only by trained
electricians. This particularly applies to
configuring intermediate cables.
b) If an accident occurs, disconnect the
welding power source from the mains
immediately.
c) If electric touch voltages occur, switch
off the welding set immediately and have
it checked by an expert.
d) Always check for good electrical
contacts on the welding current side.

GENERAL POWER TOOL SAFETY WARNINGS 

e) Wear insulating gloves on both hands for
welding. These offer protection from electric
shocks (idling voltage in the welding circuit),
harmful radiation (Heat and UV radiation) and
from glowing metal and slag spatter.
f) Wear firm, insulated footwear. Your
shoes should also protect you in wet
conditions. Open- toed footwear is not
suitable since falling droplets of glowing
metal will cause burns.
g) Wear suitable clothing, do not wear
synthetic clothes.
h) Do not look into the arc with
unprotected eyes, use only a welding
safety shield with the proper safety glass in
compliance with DIN standards. In addition
to light and heat, which may cause dazzling
and burns, the arc also gives off UV
radiation. Without proper protection, this
invisible ultraviolet radiation causes very
painful conjunctivitis, which will only be
noticeable several hours later. In addition,
UV radiation will cause sunburn-type
symptoms on unprotected parts of the
body.
i) Personnel or assistants in the vicinity of
the arc must also be notified of the
dangers and provided with the required
protection; if necessary install safety walls.
j) Ensure adequate ventilation for
welding, particularly in small rooms
since the process causes smoke and
harmful gases.
k) Do not carry out any welding work on
tanks that have been used to store gases,
fuels, mineral oil or the like, even if they
have been empty for a lengthy period of
time, since any residue will result in a
danger of explosion.

Содержание ECN-140

Страница 1: ...ORIGINAL INSTRUCTIONS SAFETY AND OPERATING MANUAL ECN 140 Inverter DC Arc Welder...

Страница 2: ...ormation necessary for using the product safely and to ensure its long service life Closely observe all safety information in these instructions General Power Tool Safety Warnings 3 Symbols and Cable...

Страница 3: ...e the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock...

Страница 4: ...tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrainedusers GENE...

Страница 5: ...otwear Your shoes should also protect you in wet conditions Open toed footwear is not suitable since falling droplets of glowing metal will cause burns g Wear suitable clothing do not wear synthetic c...

Страница 6: ...The fuses on the supply cables to the mains sockets must comply with the relevant regulations VDE 0100 To comply with these regulations only fuses or circuit breakers suitable for the cross section of...

Страница 7: ...t personnel in the vicinity are protected Unauthorised persons are to be kept away from the welding work b The walls in the immediate vicinity of stationary workplaces should not have a light colour o...

Страница 8: ...8 ECN 140 SYMBOLS AND POWER RATING CHART...

Страница 9: ...0 140A No Load Voltage 75 V Output Current Range 20 140A Efficiency 85 Protection Class IP21S Insulated Grade H Electrode Size 1 6 3 2mm Dimensions mm 230 x 96 x 150 Net Weight 2 5 KG Gross Weight 3 4...

Страница 10: ...ave finished your weld pull the rod away from the workpiece and remove any excess weld spatter with the wire brush that is supplied with your welder and a hammer Before starting a new weld inspect the...

Страница 11: ...se socket Remove refit socket 4 Current knob broken Potentiometer damaged Replace potentiometer 5 No open circuit voltage OCV Overheating See point 1 Faulty power switch Replace switch 6 Power off Pow...

Страница 12: ...d Dealer you return the product at your own cost to Autojack s or the supplying Authorised Dealer s Premises For the examination to take place clearly stating the Returns Material Authorisation Number...

Страница 13: ...pondence Failure to provide a Returns Material Authorisation Number may result in item being refused at delivery 2 2 Any issues with the product resulting in a potential claim under the guarantee must...

Страница 14: ...terruption or loss of business opportunity 3 2 This guarantee does not invalidate any rights other than these expressly set out in the guarantee and does not cover any claims for consequential loss or...

Страница 15: ...1 2RP Declares that the ECN 140 DC ARC Inverter Welder is in compliance with the regulations included in theDirectives 2006 42 EC EC DECLARATION OF CONFORMITY Certificate for EC type examination deliv...

Страница 16: ...16 ECN 140 1 Negative Socket 2 Positive Socket 3 Knob 4 Power Light 5 Overheat Light 6 Fan 7 Power Switch 8 Power Cord MACHINE SCHEMATIC...

Страница 17: ...17 ECN 140 Wiring Diagram...

Отзывы: