Maintenance  

 

Cleaning the EC Probe

 

Clean the face of the probe. Remove the shroud from the end of the probe and 

use a little kitchen liquid scouring cleaner such as “Jif" or "SoftScrub” on a 

clean

 

“Scotchbrite” nylon scouring pad. Alternatively, use 600 grit wet

-and-dry paper 

with the cleanser. Use a circular motion to scour the face of the probe and then 
rinse well in running water. Do not touch the face of the probe with your fingers, 
shake off any residual water. Replace the shroud. 

 

Calibrating EC

 

Every week you should check the EC calibration. To do this, place the probe in the 
EC 2.7 (CF 27) standard solution and allow to stand for 5 minutes. The reading 
should be 2.8 +/- 0.1 mS/cm. If not, navigate to the calibration screen, hold in the 
edit key, and use the up/down arrows to correct the displayed reading. When the 
edit button is released, the new calibration will be saved. 

 
 

Peristaltic Pump Maintenance 

These require very little maintenance.  It is important to lubricate the inner 
peristaltic tubing every 3-4 months.  Simply pinch the sides of the pump head 
to remove it from the motor.  Put 2-3 drops of lubricant on the tube at each 
roller point.  This lubricant can be purchased via your distributor.  
 
 

  
 

 
 
 
 

 

 

General Maintenance 

Frequently  inspect  your  system  for  leaks,  repair  as  soon  as  possible.  Water 
dripping  onto  power  supplies  or  pumps  could  cause  them  to  fail.  Ensure  the 
controller, pump unit and power supply are kept clean and shielded from all water 
splashes and vapours. 

Содержание EC Mini

Страница 1: ...yright 2020 Autogrow Systems Ltd 1 EC Mini Controller Installation and User Guide Simple Robust Reliable Measures EC CF or TDS Doses nutrients on demand Displays EC CF TDS Dose Count Total DCT and Dos...

Страница 2: ...ture and Settings 4 Installation 6 Maintenance 8 Fault Finding 9 Warranty and Replacements 11 Important notice When using automatic dosing equipment all chemicals must be in a form diluted state espec...

Страница 3: ...tem Failsafe Dosing Dosing may be inhibited if any of the following is detected EC outside limits detected Dose count per hour exceeded DC h These are useful if a leak should develop or the pump fail...

Страница 4: ...own arrow Readings Display EC Display Dose Count Total DCT Display Dose Count per Hour DC h Display System Status Settings S1 Set Point The desired EC Level S2 Dose Time secs The time in seconds that...

Страница 5: ...very dilute Ideally you are trying to achieve a dose time such that the EC TDS goes up by about 0 1EC 50 ppm for each dose If you need to set the dose time to a very small number to achieve this then...

Страница 6: ...dry place out of direct sunlight The sample pot is typically mounted just above the reservoir tank This ensures the flow through the sample pot is unlikely to stop completely if there is a partial los...

Страница 7: ...ring Diagram EC Mini Controller viewed from front Note that all the connections marked 24V Common are connected internally and you may connect the return wire from any solenoid valve or pump to any of...

Страница 8: ...7 CF 27 standard solution and allow to stand for 5 minutes The reading should be 2 8 0 1 mS cm If not navigate to the calibration screen hold in the edit key and use the up down arrows to correct the...

Страница 9: ...are well insulated right to the point where they enter the terminal block Then replace the fuse with a genuine 4A fuse DO NOT ATTACH WIRE OR ALUMINIUM FOIL ACROSS IT EC calibration is out or EC readin...

Страница 10: ...S TDS 500 640 700 Measured range 0 1 to 9 9EC 1 to 99CF 0 to 4999 ppm Nutrient resolution 0 1 mS cm 1 CF 50 ppm Nutrient measurement accuracy 0 1 EC 1 CF or 50ppm temperature compensated Nutrient dosi...

Страница 11: ...uction manual 1 x Instruction manual 2 x Mini Peristaltic Pumps 350ml min Warranty and Replacements If you have equipment purchased from Autogrow and it has developed a fault please complete this form...

Отзывы: