
If the rendered image is all black, it could be caused by the following:
■
No lights
: The render settings do not include natural or artificial light. For example, suppose you specify
an interior lighting scheme that uses artificial lights only, but all interior lights are turned off.
To correct this situation, in the Rendering dialog, check the lighting settings. Change them to include
natural light or artificial light, or both. See
Controlling Lighting in a Rendered Image
on page 1228. If
needed, turn on artificial lights. See
on page 1202.
■
Exposure settings
: The exposure settings are not defined correctly.
To correct this situation, check the exposure settings. In the Rendering dialog, under Image, click Adjust
Exposure. See
on page 1230.
Rendered Image Is Washed Out or Faded
Symptom
: The rendered image shows too much light, so it looks washed out or faded.
Issues and Solutions
: To solve the problem, try the following:
■
Exposure
: Check the exposure setting. Try using a darker exposure. See
on page 1230.
■
Initial Intensity
: The Initial Intensity settings for the light sources may be incorrect. In general, Luminous
Flux (lumens) provides more accurate lighting in a rendered image than Wattage. Determine the
manufacturer value for lumens, and enter this value for the Luminous Flux parameter of the Initial
Intensity dialog. (See
Changing the Initial Intensity of a Light Source
on page 1196.)
■
Wattage and Efficacy
: If you specify a Wattage value on the Initial Intensity dialog, be sure to also specify
a value for Efficacy. (If you change Wattage alone, you may make the light source unintentionally bright.)
Efficacy is the amount of light (luminous flux, measured in lumens) produced by a light source as a ratio
of the amount of energy consumed to produce it (measured in watts).
Examples: For a 100 watt tungsten incandescent (110 V), efficacy is 175. For a 32-watt fluorescent tube
(T8), efficacy is 60.
After changing the Efficacy value, render the image again. Try adjusting the Efficacy value until you
achieve the desired result in the rendered image.
Elements Are Gray in Rendered Image
Symptom
: In the rendered image, some of the elements display as gray. They do not display render
appearances as expected.
Issue
: This problem occurs when you upgrade a Revit 2008 (or an earlier release) project that uses custom
materials. During the upgrade process, Revit Architecture upgrades all standard materials to use the new
render appearances. However, it cannot upgrade any custom materials.
Solution
: Assign render appearances to the custom materials. See
Changing the Render Appearance of a
on page 475.
Entourage Did Not Render Correctly
Symptom
: The 3D view contains entourage (such as cars and people), but it did not render properly.
Issue
: This problem occurs when the entourage objects do not have render appearances assigned to them.
Solution
: Assign render appearances to the entourage objects. See
Specifying a Render Appearance for an
on page 1207.
Rendered Image Is Washed Out or Faded | 1239
Содержание 256B1-05A761-1301 - AutoCAD Revit Structure Suite 2010
Страница 1: ...Revit Architecture 2010 User s Guide March 2009 ...
Страница 4: ......
Страница 42: ...xlii ...
Страница 84: ...42 ...
Страница 126: ...84 ...
Страница 166: ...124 ...
Страница 229: ...Schedule Field Formatting Calculating Totals Specifying Schedule Properties 187 ...
Страница 230: ...Schedule with Grid Lines Schedule with Grid Lines and an Outline 188 Chapter 5 Project Views ...
Страница 304: ...262 ...
Страница 427: ...Defining the first scale vector Defining the second scale vector Resizing Graphically 385 ...
Страница 454: ...Before painting applying material to stairs 412 Chapter 8 Editing Elements ...
Страница 456: ...414 ...
Страница 486: ...444 ...
Страница 674: ...632 ...
Страница 802: ... Attachment Style Cut Column Attachment Justification Intersect Column Midline 760 Chapter 13 Architectural Design ...
Страница 809: ...Curtain wall Curtain Grid Curtain Walls Curtain Grids and Mullions 767 ...
Страница 994: ...952 ...
Страница 1016: ...974 ...
Страница 1204: ...1162 ...
Страница 1290: ...1248 ...
Страница 1318: ...1276 ...
Страница 1372: ...1330 ...
Страница 1382: ...1340 ...
Страница 1462: ...1420 ...
Страница 1492: ...1450 ...