3. Automated System Recovery 

You can recover the system simply with the previous recovery point, using the recovery 

program, installed on Autobase Touch Panel. 

 

 

3.1 System recovery   

External keyboard is required when you have to reset Autobase Touch Panel as factory state 

or repair to the recent recovery point, for reasons such as the damage of operating system or 

loss of important data. 

 

 

3.1.1 Initial state recovery 

During system boot, press the ' Home ' of the keyboard, the login dialog box will be 

appeared, as shown in <Figure 3-1>. 

 

<Figure 3-1> Login dialog box 

When <Figure 3-1> login dialog box is appeared, input user(as Administrator) and 

password(default password :admin) that you has set in the recovery program and then the 

recovery selection screen will be displayed as shown in <figure 3-2>. 

 

Содержание ATP12

Страница 1: ...Just Touch autobaseTouch Intelligent Touch Panel Computer ATP12 User Manual Ver 1 1 http www autobase biz ...

Страница 2: ...User Manual Ver 1 1 ...

Страница 3: ... manual and all about copyright of Autobase ATP series panel computer 2012 Autobase Inc All rights reserved Second edition April 2013 Notice Information in this document is subject to change without prior notice ...

Страница 4: ...ions and Panel Cut out 7 2 SERIAL COMMUNICATION PORT 8 2 1 Serial communication port 8 2 1 1 RS 232C Port 8 3 AUTOMATED SYSTEM RECOVERY 9 3 1 System recovery 9 3 1 1 Initial state recovery 9 3 1 2 Restore point update 10 4 MANUAL SYSTEM RECOVERY 12 4 1 Device driver setup 12 4 1 1 The mainboard chipset driver setup 12 ...

Страница 5: ...ver setup 16 4 1 3 Graphic driver setup 19 4 1 4 Touch screen driver setup 21 4 1 5 Ethernet driver setup 24 4 2 Programs for Autobase Touch Pro Pack 26 4 2 1 Autobase SCADA Program installation 26 CUSTOMER SERVICE 27 ...

Страница 6: ...Secondary Storage SSD 60GB Max Read 500MB s Write 400MB s or HDD 500GB SATA2 7200RPM VGA Intel GMA 3150 Serial Printer Port RS 232C 3 Ports USB USB 4 Ports Ethernet Port Dual Gigabit Ethernet 10 100 1000Mbits s LAN Ports Keyboard Mouse USB Type CD ROM OS Windows Embedded POSReady 2009 Utility Rescue Recovery Tools Included Voltage DC 12V 50 60Hz Power 38W Max 60W Weight 4 02 kg Service life of LCD...

Страница 7: ...ophone input output ports USB USB 4 ports LAN 1 10 100 1000 Base T Ethernet port LAN 2 10 100 1000 Base T Ethernet port VGA External D SUB VGA monitor output port COM 1 RS 232C input output ports COM 2 RS 232C input output ports COM 3 RS 232C input output ports COM 3 RS 232C input output ports DC IN DC 12V Power input connector ...

Страница 8: ...7 1 3 ATP12 Dimensions and Panel Cut out Figure 1 2 ATP12 dimensions unit mm Figure 1 3 ATP12 Panel cut out dimensions unit mm ...

Страница 9: ...COM2 COM3 serial ports support the RS 232C only Table 2 1 shows pin functions for RS 232C Before you connect device with serial port verify the pin functions Connector Type핀 Female Pin Number Function 1 DCD Data Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Ground 6 DSR Data Set Ready 7 RTS Request to Send 8 CTS Clear to Send 9 RI Ring Indicator Table 2 1 RS...

Страница 10: ...nt recovery point for reasons such as the damage of operating system or loss of important data 3 1 1 Initial state recovery During system boot press the Home of the keyboard the login dialog box will be appeared as shown in Figure 3 1 Figure 3 1 Login dialog box When Figure 3 1 login dialog box is appeared input user as Administrator and password default password admin that you has set in the reco...

Страница 11: ...eparing of problem occurrence to the system After booting up Autobase Touch Panel system normally double click the icon at the bottom right corner of the screen then the logon dialog box will be appeared as shown in Figure 3 3 Figure 3 3 Logon dialog box of recovery program First of all enter the user and password in Figure 3 3 the logon dialog box to log on Factory setting user Administrator Pass...

Страница 12: ...3 5 Figure 3 5 Restore point update complete dialog box Generally it is recommended to choose the disable restore option in the bottom of the dialog box And modify restore settings carefully If you choose a restore mode the system will be restored each time depending on how the selected restore mode For example if you select Restore baseline at restart the restore point will be restored whenever t...

Страница 13: ...Autobase Touch Panel after the Windows OS setup You can install device drivers from Touch System Software DVD or the Internet downloading Touch System Software DVD is included in the product package 4 1 1 The mainboard chipset driver setup Figure 4 1 Mainboard chipset driver folder ...

Страница 14: ... Driver ATP12 Chipset folder from Touch System Software DVD And run infinst911autol exe Figure 4 2 initial screen will be displayed Then select from figure 4 2 Figure 4 3 license agreement dialog box will be displayed Figure 4 2 Initial screen of the mainboard chipset driver setup ...

Страница 15: ... the driver installation if it needed an OS file Figure 4 4 screen will be appeared and then select the needed file in Driver WindowsXP_POSReady2009_SystemFiles folder of Touch System Software DVD Figure 4 4 Specify OS System Setup file When the installation is complete reboot system information screen will be appeared as shown in Figure 4 5 and proceed to reboot ...

Страница 16: ...15 Figure 4 5 Mainboard chipset driver installation complete screen ...

Страница 17: ...der of Touch system Software DVD And if you run WDM_R270 exe from Figure 4 6 the initial screen will be displayed as shown in Figure 4 7 Then if you select in Figure 4 7 it will proceed to setup During the installation the dialog box will be displayed to specify the related system file path as shown in Figure 4 8 ...

Страница 18: ...gure 4 8 Related system file location setting dialog box After the related system file location setting if you select button the audio driver installation will be completed and Windows restart setting dialog box will be displayed as shown in Figure 4 9 ...

Страница 19: ...18 Figure 4 9 Windows restart setting dialog box ...

Страница 20: ...phic driver folder If you select the provided Touch System software DVD Driver ATP12 Graphic folder the files will be displayed as Figure 4 10 And run Setup exe in Figure 4 10 the graphic driver setup initial screen will be appeared as Figure 4 11 ...

Страница 21: ...iver setup will be started When the graphic driver setup completed Figure 4 12 dialog box will be displayed and you can set whether to restart the computer or not After installing the graphic driver adjust the proper screen resolution ATP12 800 600 Figure 4 12 Graphic driver setup complete dialog box ...

Страница 22: ...button the setup program will be run and start to install the touch screen driver After you have completed the touch screen driver installation Figure 4 15 dialog box will be displayed And select button in Figure 4 15 dialog box the screen calibration program will be executed as shown in Figure 4 16 After then set the screen position of the touch screen with the calibration program of Figure 4 16 ...

Страница 23: ...22 Figure 4 14 Touch screen driver setup initial screen Figure 4 15 Touch screen driver setup complete dialog box ...

Страница 24: ...23 Figure 4 16 Touch screen calibration Figure 4 17 Tools tab of Configure utility ...

Страница 25: ...driver folder When you open Driver ATP12 Ethernet folder of Touch System Software DVD you can find files as shown in Figure 4 18 And if you run Setup exe file from Driver ATP12 Ethernet folder installShield wizard will be started as shown in Figure 4 19 ...

Страница 26: ... Wizard for graphic driver setup Then select installShield Wizard will start graphic driver setup After the graphic driver installation is completed Figure 4 20 will be appeared Figure 4 20 InstallShield Wizard Complete dialog box ...

Страница 27: ...ram installation Autobase Touch Pro Pack required Microsoft DotNet Framework Autobase SCADA Program and Autobase SCADA license by default For more details about the installable Autobase SCADA version and how to install the license contact Autobase technical support team ...

Страница 28: ...n organic solvents such as thinner benzene Malfunction by using non genuine parts or supplies ex adapter cooling fan LCD etc Repair and replacement of parts due to normal wear and tear Failure due to wrong voltage Malfunction due to the failure of connected device Damage or loss of product parts due to disassemble by consumer Defects or damages result from repairs or modifications by someone other...

Страница 29: ...r moisture to avoid fire or electric shock Unplug the power cord and all connected cables during thunderstorms Connection of Network port on the touch panel is allowed 10BASE T 100BASE T and 10000BASE T Don t connect other kinds of network cables or telephone lines Improper connection can result in the current load on the connector can cause a fire overheating or malfunctioning Don t block the air...

Страница 30: ...1201 Biz Center SKnTechno Park Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Phone 82 31 776 0800 Fax 82 31 776 0802 http www autobase biz ...