Smart AWC Duo
SAWC-400P
Change for Simple
Страница 1: ...Smart AWC Duo SAWC 400P Change for Simple ...
Страница 2: ...al Power Adapter x1 Universal Power Supply 100 240 VAC A connector to break the siphon Siphon Break x3 For rimmed and rimless aquariums up to 1 2 inch 12 7 mm Universal Tube Holder x3 Picture Item List of Parts Can Be Purchased Separately Tubing 19 6 feet 600 cm Used with DC Pumps Change for Simple Description 1 Caution Risk of Injury from Strong Magnets ...
Страница 3: ...Failsafe Sensor Low Level AWC Sensor Low Level Dual Sensor The High Level ATO AWC Sensor must be at least 1 4 inch 6 mm higher than the Low Level AWC Sensor or Smart AWC Duo will not work properly High Level Dual Sensor Low Level Dual Sensor Power DC Jack ATO Filling Pump Freshwater AWC Filling Pump Jack AWC Drain Pump Jack Saltwater AWC Filling Pump Jack ...
Страница 4: ...Waste Water Waste Water Container Tank Sump Step 4 Connect AWC drain pump to P2 Step 2 Mount the green sensor at low water level S2 with the top sensor indicating the water level on the tank sump with the magnet Arrow on siphon break indicates water ow direction Air In Water Out Note Place siphon break inside the tank sump but above the water level Siphon break allows air in to break the siphon wh...
Страница 5: ...S1 ATO water level with the lower sensor indicating the water level on the tank sump with the magnet ii Freshwater Aquarium For Freshwater aquariums P3 is not required Tank Sump Water Change Volume Step 2 Mount the green sensor at low water level S2 with the top sensor indicating the water level on the tank sump with the magnet Step 7 Connect power adapter Step 6 Connect AWC lling pump to P3 Step ...
Страница 6: ...nect AWC drain pump to P2 Air In Water Out Note Place siphon break inside the tank sump but above the water level Siphon break allows air in to break the siphon when the Air In pump turns off Water drops out of the hole are normal when the pump is on Water Out Arrow on siphon break indicates water ow direction Step 3 Connect AWC lling tube pump siphon break tubing holder Step 5 Connect AWC drain tu...
Страница 7: ...ATO Filling Pump ATO Reservoir Tank Sump Step 3 Connect ATO lling pump to P1 Arrow on siphon break indicates water ow direction Air In Water Out Note Place siphon break inside the tank sump but above the water level Siphon break allows air in to break the siphon when the Air In pump turns off Water drops out of the hole are normal when the pump is on Water Out Step 2 Connect ATO lling tube pump sip...
Страница 8: ...illing Pump ATO Reservoir Step 4 Connect power adapter Tank Sump Power AC Switch Tank Sump Optical Level Sensor Reservoir AC Filling Pump AC Power The DC pumps can be replaced with larger AC pumps with AUTOAQUA Smart AC Switch ...
Страница 9: ...sensors For example a tank is 18 inches in length and 17 inches in width If the distance between the two sensors is 3 inches the water change volume is approximately 4 gallons 18 L X 17 W X 3 H 918 cubic inches around 4 gallons The water volume might be in uenced by factors such as the speed of return pump 231 cubic inches 1 US gallon Length 18 Width 17 Water Change Volume Height 3 ...
Страница 10: ...etting Change for Simple 9 1 Turn ATO on or off 1 2 3 4 5 6 2 Choose AWC MANUAL AUTO mode or turn AWC off 1 Start pause resume the AWC process 2 Dismiss alarm 3 Choose the setting item in the AWC MANUAL AUTO mode 4 1 Increase day hour 2 Choose Saltwater Freshwater mode 5 1 Decrease day hour 2 Choose Saltwater Freshwater mode 6 1 Wake up the display 2 Dismiss alarm 3 Resume AWC process 4 Return to AW...
Страница 11: ... Aquarium Setting Mode Saltwater mode Freshwater mode 4 Pump 5 Countdown Timer AWC AUTO Mode No Colon ashes every second Timer is running Colon ashes every 3 seconds Timer pauses D ashes DAY is being set H ashes HOUR is being set shows Pump is connected and off ashes Pump pauses after power outage rotates Pump is on ashes Pump pauses ashes QST alarm ...
Страница 12: ...ter changes periodically 1 Touch until the screen shows 2 Touch and the D will ash Touch or to set the date 3 Touch again and the H will ash Touch or to set the hour 4 Touch again and the or will ash Touch or to set it 5 Touch again to save the setting 6 Touch to start the countdown timer As soon as it reaches the end the next one starts immediately If the display shows 00D 00H touching The displa...
Страница 13: ... Verify the root cause Empty Reservoir Bubble Noise Sensor is not clean Pump Failure ashes with the audible alert Timer pauses over 10 minutes Touch or to dismiss the alarm shows The High Level Failsafe Sensor detects water Touch or to dismiss the alarm shows The Low Level Failsafe Sensor detects no water Touch or to dismiss the alarm Touching or will dismiss the alarm only Please touch or again t...
Страница 14: ...ng time is 10 sec the controller will give an alert when any lling time is over 60 sec For AWC Any draining time or lling time is 3 times longer than the rst one For example if the rst draining or lling time is 20 sec the controller will give an alert when any draining or lling time is over 60 sec No security time control for the rst lling and draining AWC lling time including the lling occurring ...
Страница 15: ...te 74 gph 280 lph 3 Max Mounting Thickness 1 2 inch 12 7 mm 4 Water Change Interval Minimum 1 hour Maximum 99 days Notice 1 Please read the manual in detail before installation 2 If using another ATO instead of the built in ATO please turn off your ATO before AWC starts 3 Avoid setting up the sensors in an area with micro bubbles and direct light 4 Please keep the controller away from water and mak...
Страница 16: ...on and normal use from the date of the original purchase listed on the proof of purchase or sales receipt 4 In the event of a limited warranty claim proof of purchase or sales receipt issued to the original purchaser is required 15 Warranty Period Place of Purchase Service Purchase Date Store name phone email address Y M D AUTOAQUA Technologies Co Ltd 7F 7 NO 229 Fuxing 2nd Rd Zhubei City Hsinchu ...