background image

 

Auto

Test

 Workshop Pro User Manual 

Page 20 

7.4 Check for Updates 

The 

“Check for Updates”

 entry in the settings page allows you to toggle whether or 

not the Workshop Pro will prompt you for any available software updates. We strongly 
recommend you leave this enabled as it will help you keep the Workshop Pro up to 
date with the most recent features and fixes. 
 

 

 

Содержание Workshop Pro

Страница 1: ...User Manual Version 1 05 AUTOTest Workshop Pro ...

Страница 2: ...r part for any purpose other than that for which it was supplied by AutoTest Products AutoTest Products makes no representation undertakes no duty and accepts no responsibility to any third party who may use or rely upon this document or the information Under no circumstances shall AutoTest Products be responsible for any loss of data or income or any special incidental consequential or direct dam...

Страница 3: ...t Conditions Test Area 12 5 2 Set up in Vehicle 12 5 3 Running a test 12 5 4 Reviewing a test 13 5 5 Printing a test 14 5 6 Saving the test to read with NetBrake 14 6 DATABASE 16 6 1 Viewing Test Deleting Test or More Test Information 16 7 SETTINGS 17 7 1 Activation 17 7 2 Calibration 18 7 3 Bluetooth 19 7 4 Check for Updates 20 8 RETURN OF WORKSHOP PRO 21 8 1 Packaging 21 8 2 Shipping 21 8 3 Docu...

Страница 4: ... use the device at a refuelling point Do not use near fuel or chemicals SWITCH OFF NEAR BLASTING Follow any restrictions Do not use the device where blasting is in progress USE SENSIBLY Use only in the positions as explained in the product documentation QUALIFIED SERVICE Only qualified personnel may install or repair this product ACCESSORIES AND BATTERIES Use only approved accessories and batterie...

Страница 5: ... freight prepaid to an authorised AutoTest Service Centre Transit insurance and return freight will be at the owner s expense In order to obtain calibration warranty or non warranty service ship the product freight and insurance prepaid to your nearest AutoTest Service Centre Attach to the product your name address contact phone numbers description of the problem and if a warranty claim proof of p...

Страница 6: ... Ampang Tambahan Ampang 68000 Ampang Jaya Selangor PH 603 4291 0988 UNITED KINGDOM Tecalemit Garage Equip Co Ltd Unit 2 Eagle Road Langage Bus Pk Plympton Plymoth Devon PL7 5JY PH 017 5221 9150 UNITED STATES OF AMERICA Commercial Vehicle Consultants Inc 144 Overlook Ave Staten Island NEW YORK 10304 PH 171 8980 3651 The full list of Authorised Service Centres can be found here http www autotest net...

Страница 7: ...any software or hardware changes to your AutoTest Workshop Pro The packing box of your Workshop Pro should contain the following 1 AutoTest Workshop Pro tablet 2 USB A to Micro USB Battery Charger Data Cable 3 USB A Female to Micro USB adapter cable 4 AU Power Plug Adapter 5 2 Pole Power Socket to USB adapter Plug 6 NetBrake software suite 4 1 Activating your Workshop Pro When you power the device...

Страница 8: ...settings for the app by selecting the Location Settings Figure 2 button and enable the slider in the top right of the Location screen Figure 3 Figure 2 Figure 3 When prompted to improve location accuracy you should agree if you intend to connect your tablet to Wi Fi or provide it with a Sim card Once you have agreed disagreed hit the return button in the tablet navigation bar located on the edge o...

Страница 9: ... started Don t close the app if you want to avoid having to do this Step 5 If this isn t the first time you re activating the device then proceed to the next Step The software will be prompt you for automatic activation Select Yes and your license will become active this will activate the complimentary 6 month license you are supplied with at purchase ONLY PROCEED FROM HERE IF YOU ARE RE ACTIVATIN...

Страница 10: ...re 6 and you will be prompted with a banner directing you to contact AutoTest along with an ID number At this point you must contact AutoTest or your local supplier and provide them with your details including the ID number on screen Figure 7 ID number ONLY PROCEED FROM HERE AFTER ACQUIRING A LICENSE TOKEN FROM YOUR LOCAL DISTRIBUTOR Step 8 Find your License file and make sure it s saved somewhere...

Страница 11: ...o unit HR935 HR853 from your My Computer or equivalent Step 11 Select a location to store the token on the workshop pro device Step 12 Open the settings panel of your app Step 13 Select Activation from the settings panel Step 14 Within the subsequent prompt select I have a code ...

Страница 12: ...iple dot button 1 in the top left Step 16 If the menu has an option Show SD card then select it skip this step if it already reads Hide SD card Step 17 Now when you select the menu button in the top left 2 you should be able to see the Internal storage HR853 option choose whichever applies ...

Страница 13: ...AutoTest Workshop Pro User Manual Page 11 Step 18 Navigate to the folder location where you previously saved your license token and select it ...

Страница 14: ...nd should be less than 10kph 5 2 Set up in Vehicle Figure 8 Secured with hook loop tape Workshop Pro must be secure during the entire duration of the test Movement can cause lower worse deceleration readings This could mean test failure if the brake performance is close to the required limits Secure device in a horizontal position in the vehicle with the provided hook loop tape 5 3 Running a test ...

Страница 15: ...ate Vehicle Continue to apply the brakes until the vehicle comes to a complete stop 6 Test is prompting user to Decelerate Vehicle Continue to apply the brakes until the vehicle comes to a complete stop 7 Vehicle comes to a complete stop Test Report is generated and displayed on App screen Pull over and review test 5 4 Reviewing a test The test report component of the application contains the info...

Страница 16: ... and select it from the choose printer dialog It will begin to print out shortly 5 6 Saving the test to read with NetBrake The Workshop Pro is capable of saving test information in a format that will enable the AutoTest NetBrake software suite to generate reports for tests Before using this feature you need to have USB A to Micro USB cable A completed test on your Workshop Pro that you intend to r...

Страница 17: ...e Workshop Pro Once the Workshop Pro is connected you need to open the Workshop Pro HR935 Figure 15 in windows explorer by finding the device in the My Computer folder Figure 15 Navigate to the test data directory Figure 16 HR935 Phone storage WorkshopPro Figure 16 Now copy the contents of the Folder or the Folder itself to a location on your local Computer and note where it is stored Using the Ne...

Страница 18: ...xtbox in the top right next to the magnifying glass to filter this list for a particular value registration or time Figure 17 6 1 Viewing Test Deleting Test or More Test Information To view a test simply press the test record you intend to look at within the database window If you want to delete a test or find further information about it you can long press press and hold the screen corresponding ...

Страница 19: ... option will allow you to activate the license for your workshop pro If the device has yet to be active the button message will read Brake meter is not activated requires reactivation For instructions refer to section 4 1 of the manual This button is only active if the Workshop Pro is not activated Once activated pressing the Activation button will not do anything ...

Страница 20: ...seconds without moving it For any steps where you are unable to visually read the screen a vibration will notify you of that steps completion Calibration Process Step Calibration Status App Action User Action 1 User hits Calibration within the settings menu Calibration displays instructions with and image and window begins counting down from 5 Arrange the unit according to the image instructions M...

Страница 21: ...egin pairing a printer for use with the Workshop Pro 1 Turn on the printer you are going to use 2 At the bottom of the page press Scan for Devices 3 Wait for the device to appear underneath the Available Devices menu 4 Press and hold the entry corresponding to your printer MPT II 5 Select Pair from the displayed prompt 6 The device should shortly appear underneath the Paired Devices menu 7 Press a...

Страница 22: ...r Updates entry in the settings page allows you to toggle whether or not the Workshop Pro will prompt you for any available software updates We strongly recommend you leave this enabled as it will help you keep the Workshop Pro up to date with the most recent features and fixes ...

Страница 23: ... However the unit should be forwarded by companies such as Toll Startrack UPS or Federal Express if an expedient delivery is required 8 3 Documentation A copy of the purchase order for re calibration and a packing slip must be included with the shipment It should note the Purchase Order Number Date Serial Number and the address where the unit should be returned to 9 Maintenance and Troubleshooting...

Страница 24: ...AutoTest Workshop Pro User Manual Page 22 NOTES ...

Страница 25: ...1 63 Parsons St Kensington VIC 3031 Australia Phone 61 3 8840 3000 Sales 61 3 8840 3017 Service 61 3 8840 3016 Fax 61 3 8840 3099 Email service autotest net au info autotest net au Email sales autotest net au www autotest net au ...