10-7
CARE OF YOUR MOTORHOME
LPG TROUBLESHOOTING CHART
Symptom
Cause
Remedy
Appliance will not light
No gas
Check isolation valve is open
Low battery (auto ignition)
Charge battery
Appliance lights but goes out
Flame supervision device (FSD) Refer to dealer
immediately the FSD override
is not functioning correctly
is released
Odour
Gas leak
Turn off the gas at the isolation
valve and do not use the gas
system until the problem has
been rectified
Yellow flame
Lack of primary air. please note
Refer to dealer
yellow tipping to the flame is
normal
Orange flame
Particles of dust or dirt in the
Reduce the amount of dust in
mixing tube being carried
air
through the burner ports
Burner ports partically blocked
Refer to dealer
Floating flame
Lack of secondary air
Check all vents are clear (air
inlet to vehicle)
Blocked retention ports
Check retention ports are clear
If in an oven
Check the flue way is clear
Содержание warwick duo 2008
Страница 2: ...DATA RECORD ...
Страница 10: ...2 4 MOTORHOME CODE ...
Страница 16: ...5 2 ARRIVAL AT SITE ...
Страница 20: ...6 4 SAFETY SECURITY ...
Страница 40: ...7 20 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Страница 68: ...9 24 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Страница 69: ...9 25 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Страница 75: ...9 31 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT WARWICK DUO ...
Страница 78: ...9 34 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY WARWICK DUO ...
Страница 79: ...9 35 FITTED EQUIPMENT SINGLE BED ASSEMBLY WARWICK DUO ...
Страница 80: ...9 36 FITTED EQUIPMENT DOUBLE BED ASSEMBLY WARWICK DUO ...
Страница 84: ...9 40 FITTED EQUIPMENT ...
Страница 106: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2008 Ref 21082 ...