Auto Meter CLEAN POWER CPS-55 Скачать руководство пользователя страница 3

10

3

You have purchased Auto Meter’s Clean Power System 

designed to supply clean voltage regulated power for 

charging and maintaining battery state of charge during flash 

reprogramming, performing complex vehicle maintenance, and vehicle 

show room demonstrations. The system will deliver a regulated voltage 

up to its rated current output. The Clean Power System uses coaxial 

leads that has a separate conductor to measures and display the voltage 

that is at the battery terminals.

CONGRATULATIONS!

Auto Meter Model 
Number

CPS- 55

CPS-75

CP-100

Max. Continuous 
Output Current 

55 Amps

75 Amps

100 Amps

Maximum Continuous 
Power Output

780 Watts

1065 Watts

1420 Watts

Adjustable Voltage Range

13.0 to 14.8 V

13.0 to 14.8 V

13.0 to 14.8 V

Output Voltage 
(Full Load)

> 13.4 V

> 13.4 V

> 13.4 V

Auto Meter Digital 
Voltmeter

Yes

Yes

Yes

Field Replaceable Leads

Yes

Yes 

Yes 

Lead Cable Size

6 Gage, 6 Ft. Long 6 Gage, 6 Ft. Long 6 Gage, 6 Ft. Long

Fan Cooled

Yes

Yes

Yes

Reverse Polarity 
Protection

Yes, Fuse

Yes, Fuse

Yes, Fuse

Input Voltage 

105 to 135 VAC

105 to 135 VAC

105 to 135 VAC

Input Voltage Frequency

47 to 63 Hz

47 to 63 Hz

47 to 63 Hz

Max. AC Current

7 Amps @ 108 

VAC

12 Amps @ 108 

VAC

15 Amps @ 108 

VAC 

AC Cord Length

16 AWG, 9 Ft.

16 AWG, 9 Ft.

16 AWG, 9 Ft.

Short Circuit Protection

Yes

Yes

Yes

Thermal Protection

Yes

Yes

Yes

Operating Temperature 
Range

32 to 113 F

32 to 113 F

32 to 113 F

Storage Temperature 
Range

-4 to 176 F

-4 to 176 F

-4 to 176 F

Size

10.5 X 8.25 X 7.5   10.5 X 8.25 X 7.5  12.5 X 8.25 X 7.5

Weight

 11 LBS

11 LBS

13 LBS 

CARE AND MAINTENANCE

BATTERY

  Both jaws of each clamp 

must firmly engage the 

battery terminal. The 

copper jaw contains the 

smaller gauge wire that 

reads the voltage and 

the silver jaw contains 

the larger conducting 

wire that draws the 

load in each test. Jaw 

insulation is necessary 

for accurate readings.  

Damaged clamps or 

loose wires will affect the 

readings. Keep clamps 

clean and in good repair.

   

CHECK OFTEN FOR LOOSE JAWS 

OR DAMAGED INTERNAL PLASTIC 

SHOULDER INSULATORS

 

BATTERY LEAD & CLAMP REPLACEMENT

PROCEDURE

  Unplug small voltmeter lead connector.

  Using a screwdriver, loosen the positive and the negative set 

screws in the terminal block.

  Remove leads.

  Install the new leads into the terminal block making sure the red 

clamp lead is in the terminal block marked (+), and the black 

clamp lead is in the terminal block marked (-).

  Orientate the leads in the terminal block so that the smaller 

voltmeter leads are on top.

  Firmly tighten the set screw in the terminal block.

   Plug in voltmeter connector.