3
You have purchased Auto Meter’s Clean Power System
designed to supply clean voltage regulated power for
charging and maintaining battery state of charge during flash
reprogramming, performing complex vehicle maintenance, and vehicle
show room demonstrations. The system will deliver a regulated voltage
up to its rated current output. The Clean Power System uses coaxial
leads that has a separate conductor to measures and display the voltage
that is at the battery terminals.
CONGRATULATIONS!
Auto Meter Model
Number
CPS- 55
CPS-75
CP-100
Max. Continuous
Output Current
55 Amps
75 Amps
100 Amps
Maximum Continuous
Power Output
780 Watts
1065 Watts
1420 Watts
Adjustable Voltage Range
13.0 to 14.8 V
13.0 to 14.8 V
13.0 to 14.8 V
Output Voltage
(Full Load)
> 13.4 V
> 13.4 V
> 13.4 V
Auto Meter Digital
Voltmeter
Yes
Yes
Yes
Field Replaceable Leads
Yes
Yes
Yes
Lead Cable Size
6 Gage, 6 Ft. Long 6 Gage, 6 Ft. Long 6 Gage, 6 Ft. Long
Fan Cooled
Yes
Yes
Yes
Reverse Polarity
Protection
Yes, Fuse
Yes, Fuse
Yes, Fuse
Input Voltage
105 to 135 VAC
105 to 135 VAC
105 to 135 VAC
Input Voltage Frequency
47 to 63 Hz
47 to 63 Hz
47 to 63 Hz
Max. AC Current
7 Amps @ 108
VAC
12 Amps @ 108
VAC
15 Amps @ 108
VAC
AC Cord Length
16 AWG, 9 Ft.
16 AWG, 9 Ft.
16 AWG, 9 Ft.
Short Circuit Protection
Yes
Yes
Yes
Thermal Protection
Yes
Yes
Yes
Operating Temperature
Range
32 to 113 F
32 to 113 F
32 to 113 F
Storage Temperature
Range
-4 to 176 F
-4 to 176 F
-4 to 176 F
Size
10.5 X 8.25 X 7.5 10.5 X 8.25 X 7.5 12.5 X 8.25 X 7.5
Weight
11 LBS
11 LBS
13 LBS
CARE AND MAINTENANCE
BATTERY
Both jaws of each clamp
must firmly engage the
battery terminal. The
copper jaw contains the
smaller gauge wire that
reads the voltage and
the silver jaw contains
the larger conducting
wire that draws the
load in each test. Jaw
insulation is necessary
for accurate readings.
Damaged clamps or
loose wires will affect the
readings. Keep clamps
clean and in good repair.
CHECK OFTEN FOR LOOSE JAWS
OR DAMAGED INTERNAL PLASTIC
SHOULDER INSULATORS
BATTERY LEAD & CLAMP REPLACEMENT
PROCEDURE
Unplug small voltmeter lead connector.
Using a screwdriver, loosen the positive and the negative set
screws in the terminal block.
Remove leads.
Install the new leads into the terminal block making sure the red
clamp lead is in the terminal block marked (+), and the black
clamp lead is in the terminal block marked (-).
Orientate the leads in the terminal block so that the smaller
voltmeter leads are on top.
Firmly tighten the set screw in the terminal block.
Plug in voltmeter connector.