Power Supply Fuse 

The RIO 425 module shall be 
protected with an external 2A fuse on 
the supply line. 

Wire Requirement 

Supply wires shall have a minimum 
area of 1mm

2

 (~17 AWG). 

Communication to the 
DCU  

The RIO 425 comes preconfigured to 
communicate with the DCU 
410(E)/408(E) or DCU 210(E)/208(E) in 
the Auto-Maskin Marine Pro range. 
It can be used together with other RIO 
expansion modules on the same RIO 
link. 

Note! Only one RIO 425 can be used 
on a RIO link. 

Communication Wiring 

Depending on the DCU model connect 
the wires in the shielded 
communication cable to the terminals 
as shown in the table below: 
 

RIO 
425  

DCU 
410(E)/ 
408(E)  

DCU 
210E/ 
208E 

DCU 
210/ 
208  

( )

 

57 

( )

 

 

22 

( )

 

B (L) 

58 (L) 

C1-5 (L)  23 (L) 

A (H) 

59 (H) 

C1-6 (H)  24 (H) 

 

Note! Do not connect the 

cable shield ( ) at both ends. 

 
To minimize the effect of external 
noise it is recommended to use 
twisted pair wires. 
 

Communication bus 
termination resistor 

Note! Do not skip this section! 

The 120 ohm (1/4 W) termination 
resistor shall be connected at the last 
RIO unit (furthest away from the DCU) 
in the RIO link chain.  
If the RIO 425 is the only unit on the 
RIO link, then the termination resistor 
shall be connected at the RIO 425. 
Connect the resistor directly across 
terminals A and B on the RIO 425. 
If the RIO 425 is 

not

 the last RIO unit 

on the link, then the termination 
resistor shall not be connected to the 
RIO 425, but at the last RIO unit on the 
RIO link. 

 

 

If there are 
several units 
attached to the 
link add the 120 
Ohm resistor 
together with 
the last unit on 
the bus. 

 
The DCU has an inbuilt termination 
resistor at its end.  
When the bus is properly connected, 
the measured impedance between bus 
terminals A and B shall be 60 ohm 
(+/- 5 ohm). 

 
 

 
 

Содержание RIO 425

Страница 1: ...Manual 1100276 Installation Manual RIO 425 AC Generator Interface ...

Страница 2: ......

Страница 3: ...scription 1 0 12 08 2019 Initial Release Revision Upgraded from former QIG ver 1 Copyright 2010 2019 by Auto Maskin All rights reserved No part of this document may be reproduced or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Auto Maskin www auto maskin com ...

Страница 4: ...N OF THE RIO 425 2 INTRODUCTION 2 OPERATING CONDITIONS 2 WIRING 2 Power Supply 2 Communication to the DCU 3 Generator Voltage Interface 4 Generator Current Interface 4 CONFIGURATION 4 Configuration from the DCU web server 5 Configuration using the user interface 5 SCHEMATIC 7 APPENDIX 8 Setup RIO 425 communication parameters 8 ...

Страница 5: ...ed personnel Installation or work on the shore power equipment must only be carried out by electricians authorized to work with such installations Responsibilities It is the sole responsibility of the installer to ensure that the installation work is carried out in a satisfactorily manner that it is operationally in good order that the approved material and accessories are used and that the instal...

Страница 6: ...y 5 to 95 RH without condensation Wiring The RIO 425 has these main connections AC Power Supply Communication to the DCU Generator voltage interface Generator current interface When properly connected and communicating to the DCU on the RIO link the DCU will automatically detect the RIO 425 and add an instrument page similar to the one below Power Supply AC or DC Power Supply The RIO 425 can opera...

Страница 7: ...ot connect the cable shield at both ends To minimize the effect of external noise it is recommended to use twisted pair wires Communication bus termination resistor Note Do not skip this section The 120 ohm 1 4 W termination resistor shall be connected at the last RIO unit furthest away from the DCU in the RIO link chain If the RIO 425 is the only unit on the RIO link then the termination resistor...

Страница 8: ...terface as follows Generator phase RIO 425 terminal N 13 L1 12 L2 11 L3 10 Wire requirement Wires shall have a minimum area of 1 0 mm2 16 AWG Generator Current Interface Connect the generator current interface as follows Phase Current transformer RIO 425 terminal L1 S1 S2 1 2 L2 S1 S2 3 4 L3 S1 S2 5 6 Wire requirement The wire area shall be minimum 2 5 mm2 12 AWG Configuration The RIO 425 can be c...

Страница 9: ...press the max key to increase the value of the flashing digit When the required value is reached move on to the following digit by pressing min When the last digit has been changed or verified press min to move back to the first digit allowing the previously set values to be changed again To save the data and proceed press Voltage Transformer Secondary value Note If there is no voltage transformer...

Страница 10: ...digit When the required value is reached move on to the following digit by pressing min When the last digit has been changed or verified press min to move back to the first digit allowing the previously set values to be changed again To save the data and proceed press Current Transformer Secondary value Note The RIO 425 comes preset to a transformer ratio of 5 1 meaning the secondary current varie...

Страница 11: ...tallation of the RIO 425 Note The voltage transformer may or may not be necessary Consult the RIO 425 datasheet for supply voltage range The RIO link communication interface is not shown on the schematic The 3 pin communication interface connector is on the underside of the module ...

Страница 12: ...button Press to proceed Peripheral number Next the screen shall display Set nPer 0 255 Make sure the value is set to 25 using the and button Press to proceed Transmission speed Next the screen shall display Set baud 1200 19200 Make sure the value is set to 19200 using the button Press to proceed Parity Next the screen displays Set Pari no even odd Make sure the value is set to Even using the or bu...

Отзывы: