FACTORY REGISTRATION FORM
AUTOMATIC DOOR MAINTENANCE SERVICE PROGRAM TERMS
I.
Parts to be on 2 year warranty.
II.
Labour to be on 12 months warranty.
III.
All service work warranted for 90 days.
IV.
Service to be carried out every quarter at ________________________ GST per door operator.
V.
This service program will be for an initial term of one (1) year and will be terminable thereafter by three
months written notice. Service cost may only be reviewed after the initial term and every subsequent term.
VI.
All work carried out to comply with AS 5007-2007 and BCA requirements.
VII. All work to be performed by AUTO INGRESS PTY LTD or its accredited service agents.
SERIAL NO: ___________________ DATE OF COMMISSION: ________________________
LOCATION: _______________________________________________________________
_______________________________________________________________
PLEASE SELECT ONE OF THE TWO OPTIONS BELOW:
1. The service offer set out above incorporating the warranty is hereby accepted
2. We are aware of the maintenance service requirements and the possible safety
hazards when this equipment is not regularly maintained as required by AS5007.
We however decline to take up the safety maintenance offer at this time
Authorised Signature: _________________________________________________________________________
Name: _____________________________________________________________________________________
Dated this; __________________________ Day of ___________________________ 20 ___________________
Company Name: _____________________________________________________________________________
Postal Address: ______________________________________________________________________________
______________________________________________________________________________
Please contact the person named below to arrange the mandatory service: _________________________________
Contact Name &Number: ______________________________________________________________________
Please note that the factory registration is an absolute requirement in all cases and may also be done by our
national toll free phone 1300 138 750 or visiting our web site at www.autoingress.com.au
LOGICSLIDE - LogicSwing Owners Operating Instructions
These models are equipped with a microcomputer that automatically sets the open and close positions of the door. The microcomputer utilises a digital mode
pad to communicate to and fro with users as below:
1. Mode changes:
AUTO
– two way traffic. 2.
EXIT
- one way exit only 3.
LOCK
– Both the entry and exit sensors are disabled. Door will lock if
an electric lock is fitted or allow mechanical lock to be engaged by the user. When electric lock is fitted an afterhours entry switch and egress
push button is required for entry or exit. With manual locking doors the mode is changed to lock but sliding the door will open it for entry and exit
unless the mechanical lock is engaged.
OPEN
– The door will remain in the open position.
MANUAL
- The door will switch the motor off to allow
mechanical operation while the mains power is still on.
2.
Keypad Mode Change Procedure:
Press the mode key followed by the user code (1234 – Default). Press the mode Key repeatedly till the
desired mode is displayed. Press enter to select. Key pad will confirm by saying mode sent ok.
Note:
If a 3 or 4 position switch is used for mode change or the door is controlled by an access control system / building management system,
the mode on the key pad should be left on
AUTO
permanently. Change mode by turning the key or knob. If a hand held remote is used press lock
or open button or hold open button for the appropriate function. Press reset for Auto Mode.
3.
Warnings:
The door provides audible beeping and may display error messages. This occurs when: a. the battery has failed – wait to see
if the battery will recharge before calling for service b. if fitted when the door requires routine service as required by the Australian Standard
AS5007-2007 (the door will require a one off registration code available by calling the phone number displayed on the mode pad). c. If errors or
operational problems such as door obstruction occurs.
Note:
The audible alarm can be silenced for 48 hours 3 times prior to requiring a technician for service.
Silence Alarm Procedure:
When key pad is fitted press the setup key followed by the user code. Setup: Local is displayed – press the enter key
to select. Silence Buzzer 48H is displayed – press the enter key to select. Confirm reset is displayed – press the enter key to confirm. Buzzer
reset ok is displayed. Press the exit key twice to save changes - done.
4.
Setup Local:
Allows the user access to the following:
a. Show timed lock/unlock – allows user to see lock and unlock times if the built in time clock is enabled.
b. Disable/Enable timed lock – this allows the user to override the time clock.
c. Set Day and Time – allows day and time adjustment.
d. People counter – allows user to view and reset the count of people entering and exiting.
e. Change User code – user may select or change their own code.
f.
Managed Lock
– used in lock mode to override safety sensor on closing to obtain lock
up on sensor failure or damage.
Note: For local setup and adjustments press the setup key followed by the user code. Select the
menu items and confirm your selection by pressing the enter key. Discard changes or escape
setup by pressing the exit key.
Service Guide:
Door will not close:
1. Check mode is not on open or manual.
2. Check mains power is on
3. Check nothing is activating the sensors. No moving signs or plants etc.
4. Check nothing is blocking the safety sensors – refer managed lock in (f) above to
over ride if emergency lock up is required.
5. Check doors are not obstructed or jammed.
Door will not open:
1. Check mains power is on
2. Check mode is set to auto
3. Check doors are not obstructed or locked.
Quick Fix – Reset:
In most cases service problems can be eliminated by rebooting or resetting the
doors by one of the three methods below.
The door will open and close for one cycle very slowly to predetermine its operating parameters.
1. Press and hold key no. 2 or up arrow on the mode or key pad for 10 seconds.
2. Press the reset button accessible through a hole on the underside of the key
pad using a pen or similar.
3. Switch mains power off for 30 seconds then on again. If in lock mode change to
auto or press the exit button.
AutoIngress Inline Logo Specifications
Typeface
Logo Options
Hexadecimal
Hexadecimal
#F47735
#000000
#000000
#000000
PrOjecT NO.:
AUT0001
PrOjecT Name:
AUToIngreSS MASTer Logo
DrawiNg TiTLe:
AUToIngreSS MASTer Logo
cLieNT:
AUToIngreSS
DesigNer:
MArTy TowerS
DaTe Of issue:
10.02.2010
cHeckeD: aPPrOveD:
LM
MT
cmYk
cmYk
C
M
y
K
C
M
y
K
0
70
100
0
0
0
0
60
C
M
y
K
0
0
100
0
C
M
y
K
0
0
0
100
Pantone
Pantone/cmYk
mono
172
colour Palette
Primary: Futura Light*
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
1234567890()[]{}|_+-
=:;<>?/!@#$%^&*
Secondary: Futura Medium*
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
1234567890()[]{}|_+-=:;<>?/!@#$%^&*
* Futura was the base font used to design the AutoIngress logotype, but it was
extensively modified in order to acheive a more dynamic outcome.
AUTO INGRESS PTY LTD
A.C.N. 083 047 241 A.B.N. 53 083 047 241
PO Box 825
Springwood Qld 4127
46 Rowland Street
Slacks Creek Qld 4127
AUSTRALIA
Ph: (07) 3290 1500
Fax: (07) 3290 1567
Australia Wide
Ph: 1300 138 750
Fax: 1300 138 756
Email: [email protected]
Website: www.autoingress.com.au
q
q