- 22 -
4. Feeds the media through the rear external
label entrance chute. And place the paper,
printing side face up, through the media
sensor and place the label leading edge
onto the platen roller. Move the media
guides to fit the label width by turning the
guide adjuster knob.
5. Disengage the top cover support and close the top cover gently.
6.
Use “Diagnostic Tool” or LCD menu function to set the media sensor type and calibrate the
selected sensor.
Note:
Please calibrate the gap/black mark sensor when changing media.
Please refer to the diagnostic utility quick start guide for more information. (Start the
“Diagnostic tool”
Select the “Printer Configuration” tab
Click the “Calibrate Sensor”
button )
Please refer to the section 6 for LCD menu function.