The voltage-dependent input current of Driver incl. LED module is depending on the used load.
The voltage-dependent no-load current of Driver (without or defect LED module) is for:
AC: < 12.4 mA
DC: < 4.5 mA
Software / programming
With appropriate software and an interface different functions can be activated and various
parameters can be configured in the LED Driver.
To do so, a DALI-USB or ready2mains programmer and the software (masterCONFIGURATOR)
are required.
masterCONFIGURATOR
From version 2.8:
For programming functions (CLO, I-select 2, power-up fading,
corridorFUNCTION) and device settings (fade time, ePowerOnLevel, DC
level, etc.). For further information see masterCONFIGURATOR manual.
10. Miscellaneous
Isolation and electric strength testing of luminaires
Electronic devices can be damaged by high voltage. This has to be considered during
the routine testing of the luminaires in production.
According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A,
each luminaire should be submitted to an isolation test with 500 V DC for 1 second.
This test voltage should be connected between the interconnected phase and neutral
terminals and the earth terminal.
The isolation resistance must be at least 2 MΩ.
As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength
with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this
test must not be conducted.