background image

 

 MANFACTURER OF INDUSTRIAL MARINE AND OIL & GAS VALVES

 

IN BRONZE AND ALUMINIUM-BRONZE 

93, rue Louis Blanc - 02300 CHAUNY - FRANCE 

Tel: +33 (0)3.23.52.02.86 - Fax: +33 (0)3.23.39.52.28 

www.autexier.fr 

 
 

Instructions of assembly and maintenance for visual level controller 

 

 

 

149 / 150 / 449 / 450 / 184 / 186 / 2184 / 3184  / 276 / 278 / 2276 / 274 / 275 / 277 / 349 / 350  

 

I) Checking at the delivery

 

 

Check at receipt that the packaging has not been damaged, that the delivered visual level controller is in accordance 
with your order and that the material is not damaged. 
 

II) Storage 
 

The visual level controllers can reach the site several months before commissioning. Performance may be degraded 
if special care is not taken in their storage and protection. 
 
It is recommended to store the visual level controllers in a clean, closed, protected from weather and projections of 
sand,  dust  and  other  solid  particles.  Leave  them  as  much  as  possible  in  their  original  packaging.  The  plugs, 
protections  threads,  plastic  envelopes,  will  be  removed  at  the  time  of  installation.  Avoid  impacts  on  the  sealing 
surfaces of the threads. 
 

III) Assembly of the visual level controller 
 

1) The visual level controllers must be handled with particular care. Prevent the ingress of foreign bodies in the visual 
level controllers reflex glass indicators during installation and operation. 
2) This equipment can not be installed in an explosive area. 
 

IV) Instructions 

 

1) It is strictly forbidden to neutralize the mechanism of the visual level controllers. 
2) Any foreign body must block the entries of the visual level controllers. 
3)  The  visual  level  controllers must  be  installed  in  a  place  where  there  is  no  risk  of  shock  or  water  hammer  which 
would endanger working. 
4) Insulate the equipment if the temperature of contact requires it (for staff in case of explosive atmosphere in or out 
of  the  equipment),  and  allow  only  the  access  to the  approved  staff.  For  the  equipment,  it  is  imperative  to stay  in  a 
beach temperature indicated on the identification plate (Rep. 

3

) or failing on the product data sheet. Take care not to 

have fluid in changing state (gel) may damage the tube. 
5)  It  is  imperative  to  respect  the  conditions  of  use  stated  (pressure,  temperature,  fluid)  during  your  request  to  our 
services (no corrosive fluids or fluids which may cause significant wear, no unstable fluids from which decomposition 
may  cause  risk,  do  not  use  several  fluids  likely  to react  each  other  to generate  derivatives  leading  to  an  explosive 
atmosphere or may not viscous fluids solidify at a moment or another). 
6) Limit as much as possible the tensions due to failure alignments of the piping connections system. 
7)

 

It is necessary to eliminate any previous and post pressure before removing the level indicator and be sure not to 

create an explosive inside or outside the  reflex glass indicator. The staff operating the setting up of the  visual level 
controller will be trained to perform this operation and will wear all necessary protections linked to the carried fluid. 
8) Do not let the mechanism in intermediate position for a long time to avoid any phenomenon of cavitation and/or 
erosion. 