35
7)
Press the
ESC
button to return to
Diagnostic
Menu.
5.6
O2 Monitor Test
OBD2 regulations set by SAE require that relevant vehicles
monitor and tests on the oxygen (O2) sensors to identify problems
related to fuel efficiency and vehicle emissions. These tests are not
on-demand tests and they are done automatically when engine
operating conditions are within specified limits. These test results
are saved in the on-board computer's memory.
The O2 Monitor Test function allows retrieval and viewing of O2
sensor monitor test results for the most recently performed tests
from the vehicle's on-board computer.
The O2 Monitor Test function is not supported by vehicles which
communicate using a controller area network (CAN). For O2
Monitor Test results of CAN-equipped vehicles, see chapter
“On-Board Mon. Test”.
1)
Use the
UP/DOWN
scroll button to select
O2 Monitor Test
from
Diagnostic
Menu
and press
OK
button. (Figure 5.3)
2)
Wait a few seconds while the scan tool validates the PID MAP.
3)
Use the
UP/DOWN
scroll button to select O2 sensor
from
O2
Monitor Test
menu and press
OK
button. (Figure 5.24)
Figure 5.24
If the vehicle does not support the mode, an advisory message
will be displayed on the screen. (Figure 5.25)
.......... ..
O2 Monitor Test
…
1.O2 Bank1 Sensor1
2.O2 Bank1 Sensor2
3.O2 Bank2 Sensor1
4.O2 Bank2 Sensor2