Receiving unit Type R202 TECHNICAL DATA
Power supply
Antenna
Max switching capacity of STOP contacts
Max switching capacity of SAFETY contacts
Max switching capacity of command contacts
Fuse F1 (STOP circuit)
Fuse F2 and F3 (SAFETY circuit)
Fuse F4 and F5 (POWER SUPPLY)
Working temperature
Housing
Minimum protection grade
Dimensions
Weight
*Capacity only valid if both terminals are used for each contact.
If the radio remote control output have been cabled by Autec, please see technical data sheet.
24/48/55/110 Vac ±20% 60 Hz (15VA)
integrated or dedicated
4A (250Vac)
4A (250Vac)
10A (250Vac)
*
4A T 250V (5x20 mm)
4A T 250V (5x20 mm)
1A T 250V (5x20 mm)
-4°F - +158°F
nylon (20% fg)
IP65
(202x381x91) mm
max 3,5 kg
The master boards on this type of receiving unit may be:
- E16B16AC for configurations of up to 16 commands
- E16B22AC for configurations of up to 22 commands (plus extension interface card)
E16B16AC
F1
F2
F3
E16B22AC
LIE&LAA0
F5
F4
F5
F4
F1
F2
F3
Page 6
F1
STOP circuit protection fuse
F2
F3
SAFETY circuit protection fuse
F4
F5