AUTEC - Air series
Technical data
3
LIRLBE00-03
2
Technical data
Power supply .......................................................................................... 45-240V (0.4A)
Power supply protection fuse ......................................................... 1.6A T 250V (5x20mm)
Antenna ............................................................................................. internal or dedicated
STOP contacts rated current .......................................................................... 4A (250V )
STOP contacts protection fuses ....................................................... 4A T 250V (5x20mm)
SAFETY contacts rated current ...................................................................... 4A (250V )
SAFETY contacts protection fuses ................................................... 4A T 250V (5x20mm)
Commands rated current ................................................................................ 6A (250V )
Housing material .......................................................................................... PA 6 (20%fg)
Protection degree ....................................................................................... IP65 (NEMA 4)
Dimensions ................................................................ 123x202x83mm (4.84x7.95x3.23In)
Weight ........................................................................................................... 1.2kg (2.7Lb)
A
222 mm
B
106 mm
C
82 mm
D
213.5 mm
3
Technical data sheet
The technical data sheet contains the wiring diagram showing the connection between the
receiving unit and the machine. It also contains the transmitting unit configuration and shows
the matching between commands sent and machine functions/movements.
Each technical data sheet must be filled in, checked and signed by the installer, who is
responsible for a correct wiring.
A technical data sheet must always be kept toghether with this manual (always keep a copy
of the technical data sheet when it is used for administrative purposes).
The wiring of the receiving unit outputs must always reflect the wiring
indicated in the technical data sheet.
Содержание Air ACRS13-L