10
english
9.2 Technical Data
Modell
45x K
45x51
KII
55x K
65x K
75x K
75x39
KII
38x38x57
K
55x55x
K
63x40x42
K
Testing according to DIN EN
13229
CE - Marking
Nominal output
kW
6
6
7
8
10
10
5
7
8
Max. heating capacity
kW
8
8
9
11
15
15
6
9
11
Max. firewood length
cm
33
33
33
33
33
33
33
33
33
Permissible quantity of fuel
kg
1,7
1,7
1,9
2,35
3,2
3,2
1,34
1,9
2,35
Fuel throughput
kg/h
1,7
1,7
2
2,3
2,85
2,85
1,6
2
2,3
Cross section convection outlet
cm²
700
700
700
700
700
700
500
700
700
Cross section convection inlet
cm²
700
700
700
700
700
700
500
700
700
Power output via window
%
14/17/17
23
14/17/20
17/20/20
17/23
29
37
32/35
37
Emission limits
CO based on 13% O
2
mg/m³
≤1250
≤1250
≤1250
≤1250
≤1250
≤1250
≤1250
≤1250
≤1250
Dust based on 13% O
2
mg/m³
≤40
≤40
≤40
≤40
≤40
≤40
≤40
≤40
≤40
CnHm
mg/MJ
≤50
≤50
≤50
≤50
≤50
≤50
≤50
≤50
≤50
NOx based on 13% O
2
mg/m³
≤150
≤150
≤150
≤150
≤150
≤150
≤150
≤150
≤150
Efficiency
min.%
≥80
≥80
≥80
≥80
≥80
≥80
≥80
78,9
≥80
Exhaust gas temperature***)
°C
354/371/387
292
275/313/351 283/298/317 313/300
286
273
330
230
Exhaust gas mass flow
g/s
5,1/5,2/5,2
5,5
5,9/6,0/6,2
7,3/7,7/6,8
8,1/7,7
7,3
5,0
7,5
7,65
Minimum discharge pressure
Pa
12
12
12
12
12
12
12
14
12
Distances from the fireplace insert
to the firebox wall
cm
6
Information on fire and heat protection (data in mm Promasil 950 KS)
Insulation thicknesses
to the installation floor
mm
60
20
60
60
60
20
-
-
-
at the side/rear
mm
90
130/-
90
90
120
130/-
90
60
100/120
to the ceiling
mm
according to the national or local standards (e.g.: TR OL, FeuVo)
Radiation area side viewing window
cm
--
-
--
--
--
--
85
80
110
Radiation area front viewing window
cm
80
110
80
80
80
80
85
80
110
Combustion air
Combustion air connecting
hose (K/S)
Ø mm
125
125
125
125
125
125
125
125/150
150
Combustion air requirement
(A1)
m³/h
12
17,8
14
17,5
19,5
16,71
12
22
44
Application with a special construction
Hypocausts**)
suitable in compliance with technical regulations
*)
under examination
**)
The Austroflamm appliances marked with "suitable in line with technical regulations" are suitable for
operation in closed systems (hypocaust).
***)
on the connecting piece of the appliance at nominal heat output
10 Warranty and Guarantee
Installation and delivery of the device by a specialist company are prerequisites for the manufacturer's
warranty, as is compliance with the applicable building regulations. We would also like to point out that the
fireplace must not be modified. Any structural changes or use other than for the intended purpose will render
any warranty claim null and void!
We guarantee flawless operation of the body of your Austroflamm fireplace insert for 6 years. All other steel
and cast iron components are guaranteed for 2 years from the date of first sale. Steel and cast iron parts that
show material and/or processing defects during the warranty period will be replaced with new parts.
We do not grant any warranty for wear and tear parts (e.g. ceramic, seals, floor grating), surface coatings,
paintwork and glass. Our warranty service includes new parts free of charge. Labour and travel times are not
included.
An unjustified warranty claim will be charged to the provider.
EN
FIREPLACE INSERTS / HINGED DOORS
10
www.austroflamm.com
Содержание 38x38x57 K
Страница 2: ......
Страница 3: ......
Страница 15: ...NOTIZEN NOTES DE KAMINEINSÄTZE KLAPP 11 www austroflamm com ...
Страница 27: ...NOTIZEN NOTES EN FIREPLACE INSERTS HINGED DOORS 11 www austroflamm com ...
Страница 39: ...NOTIZEN NOTES IT MONOBLOCCHI A LEGNA A BATTENTE 11 www austroflamm com ...
Страница 52: ...NOTIZEN NOTES 12 www austroflamm com ...
Страница 53: ...NOTIZEN NOTES 13 www austroflamm com ...
Страница 54: ...NOTIZEN NOTES 14 www austroflamm com ...
Страница 55: ......