background image

S Y D N E Y

( N S W   &   AC T   S A L E S )

149 Beaconsfield

Street Silverwater

NSW 2128 

Private Bag 149

Silverwater NSW 1811

Phone: (02) 9647 1411

Fax: (02) 9648 3698 

Email:

[email protected]

M E L B O U R N E

( V I C   &   TA S   S A L E S )

22/277 

Middleborough Road

Box Hill VIC 3128 

PO Box 151 Blackburn

South VIC 3130 

Phone: (03) 9890 7477

Fax: (03) 9890 7977 

Email:

[email protected]

B R I S B A N E

( Q L D   S A L E S )

42 Commercial Road

Fortitude Valley 

QLD 4006 

PO Box 871 Fortitude

Valley QLD 4006

Phone: (07) 3852 1312

Fax: (07) 3252 1237 

Email:

[email protected]

A D E L A I D E

( S A   &   N T   S A L E S )

31 Walsh Street

Thebarton 

SA 5031 

PO Box 157 

Hindmarsh SA 5007 

Phone: (08) 8352 4444

Fax: (08) 8352 4488 

Email:

[email protected]

P E RT H

( WA   S A L E S )

299 Fitzgerald Street

West Perth WA 6005 

PO Box 404 

North Perth 

WA 6906

Phone: (08) 9228 4222

Fax: (08) 9228 4233 

Email:

[email protected]

AU C K L A N D

( N Z   S A L E S )

Unit B, 11 Piermark

Drive Albany 1331

New Zealand

PO Box 512 

Albany 1331

Phone: (09) 415 9426

Fax: (09) 415 9864 

Email:

[email protected]

AU S T R A L I A   A N D   N E W   Z E A L A N D

w w w. a u s t ra l i a n m o n i t o r. c o m . a u

I N T E R N AT I O N A L   S A L E S

149 Beaconsfield Street Silverwater NSW 2128 Australia

Private Bag 149 Silverwater NSW 1811

Phone: 61 2 9647 1411 

Fax: 61 2 9648 3698 

Email: [email protected]

S E N N H E I S E R   E L E C T R O N I C   C O R P O R AT I O N

1 Enterprise Drive

Old Lyme CT 06371 USA

Phone: 1 860 434 9190

Fax: 1 860 434 1759 

Email: [email protected]

E U R O P E / A S I A / M I D D L E   E A S T

w w w. a u s t ra l i a n m o n i t o r. c o m . a u

U S A / S O U T H   A M E R I C A

w w w. a u s t ra l i a n m o n i t o r. c o m

Содержание MX61

Страница 1: ...6 CHANNEL MIC LINE MIXER INSTALLATION AND OPERATION MANUAL MX61 ...

Страница 2: ...k fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug weathersheet carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign matter 14 Do not remove the cover Removing the cover will expose you to ...

Страница 3: ...h Headphone out Record out also available the MX61 is extremely versatile represents excellent value for money Thankyou for purchasing the Australian Monitor Installation Series MX61 INTRODUCTION 3 FRONT PANEL 4 REAR PANEL 5 INTERNAL ADJUSTMENTS 6 INSTALLATION TROUBLESHOOTING 7 BASIC SETUP OPERATION 8 DIMENSIONS 9 BLOCK DIAGRAM 10 SPECIFICATIONS 11 This symbol is intended to alert the user to the ...

Страница 4: ...rol is post status LED and as such the status LED is NOT affected by the level control If an input channel is clipping use the gain control to adjust the correct amount of input level OUTPUT TONE CONTROLS The output has a 3 band EQ Bass 12dB 100Hz shelving Mid 12dB 1 6kHz Q 1 4 Treble 12dB 10kHz shelving MASTER This pot controls the overall mixed output HEADPHONE This 1 4 jack socket allows headph...

Страница 5: ...R input REC OUT The REC OUT output is on unbalanced RCA connectors The output is dual mono and is not affected by the MASTER volume control or the EQ tone controls OUTPUT The OUTPUT XLR provides balanced line level signal NOTE When wiring the LINE output as unbalanced Pin2 should be wired as hot and Pin1 should be wired as ground shield Do not wire Pin3 24VDC SOCKET This 2 1mm x 5 5mm barrel socke...

Страница 6: ...el 8 to set channel 1 to post master fader HEADPHONE ROUTING The headphone level can be routed so that it is affected by the master volume The default factory setting is pre master fader meaning the master volume does not affect the headphone volume The jumper header is located just behind the front panel above channel 6 pot Move the jumper to link the two pins nearer the inputs to set the headpho...

Страница 7: ...red as ground shield Do not wire Pin3 RECORD OUTPUT The Record output wiring should be kept as short as possible Typically less than 3m INSTALLATION TROUBLESHOOTING TROUBLE LIKELY CAUSE REMEDY Power LED not on Power not reaching unit Check mains connection Check mains fuse Check power switch is on Poor S N ration Incorrect gain structure See setup guide Distorted sound Input is overloaded Reduce i...

Страница 8: ...one set the MIC LINE switches to the MIC position If the source is an electret or condenser microphone set the phantom switch to the P P on position CONNECT THE OUTPUTS Turn the amplifiers off Connect the MX61 output to the amplifiers line level input Check that the MX61 is on and then turn on the amplifiers If the amplifiers have a level control set them it to a sensitivity of 0dBu If in doubt se...

Страница 9: ...MX61 INSTALLATION OPERATION MANUAL PAGE 9 DIMENSIONS ...

Страница 10: ...PAGE 10 MX61 INSTALLATION OPERATION MANUAL BLOCK DIAGRAM ...

Страница 11: ...A 30dBu MAX LEVEL OUT 21dBu PHANTOM POWER 15V DC OUTPUTS MASTER OUT Nominal Level 0dBu into 1kohm Imp 100ohm MONO HEADPHONE OUT Nom 6dB into 200ohm Imp 10ohm MONO REC OUT Nom 12dB into 10kohm Imp 10kohm POWER INPUT AC 230V 50Hz or 115V 60Hz 3 pin IEC320 C14 connector DC 24 Volts via 2 1mmx5 5mm DC socket POWER CONSUMPTION MAX 7 VA FUSES MAINS 115V 120mA MAINS 230V 63mA DIMENSIONS h x w x d 44mm x ...

Страница 12: ...Email sa audiotelex com au PERTH WA SALES 299 Fitzgerald Street West Perth WA 6005 PO Box 404 North Perth WA 6906 Phone 08 9228 4222 Fax 08 9228 4233 Email wa audiotelex com au AUCKLAND NZ SALES Unit B 11 Piermark Drive Albany 1331 New Zealand PO Box 512 Albany 1331 Phone 09 415 9426 Fax 09 415 9864 Email sales audiotelex co nz AUSTRALIA AND NEW ZEALAND www australianmonitor com au INTERNATIONAL S...

Отзывы: