Installation
Power Requirements
Ensure that
your
mains voltage is the same as the rear panel mains voltage
marker (+/- 10%).
Mounting
Your amplifier is designed for standard 19” rack mounting and occupies 2 EIA
rack units.
Cooling
Each channel of your
IS
Series amplifier is cooled by an axial fan which draws
cool air from the front of the amplifier and expels heated air out the rear of
the amplifier. These amplifiers include two-speed fans which normally run at
half speed, switching to full speed when the internal heatsink temperature
exceeds 50
0
C.
An unrestricted airflow into and out of the amplifier must be
provided
. Any restriction of the air flow will cause heat to build up within the
amplifier and possibly force the amplifier into its thermal shutdown mode. If