background image

IMGC450  

INSTALLATION AND OPERATION MANUAL

4

INSTALLING SHOCK MOUNT & 
IMGC450 MICROPHONE

The shock mount is designed to be flush-mounted and 
provides isolation to reduce room-rumble and mechanical 
noises from being amplified.

Installing the Shock Mount

 

Choose a suitable flat surface to install the shock 
mount.

 

Using a hole saw cut a 51mm (2inch) diameter 
hole through the mounting surface

 

Slide the shock mount into the freshly cut hole 
and mark the location of the three screw holes 
using a marker or punch.

 

Using a 3.0mm drill pre-drill three pilot holes.

 

Insert the shock mount into the hole again and 
fasten down the shock mount with the 3 screws 
provided.

Installing IMGC450 into the Shock Mount

 

To install the IMGC450 into the Shock Mount  
unscrew the bottom plastic screw collar.

 

Slide the IMGC450 body into the Shock Mount.

 
 

Re-install the bottom plastic screw collar until snug.

 

Be careful not to cross thread or crack the plastic 
screw collar.

 
 

Insert a female 3-pin XLR connector into the  
microphone base.

 

Phantom power is required for the IMGC450  
to operate.

 

To avoid possible loudspeaker damage ensure  
the PA system is muted first before you enable  
phantom power.

1

1

2

2

3

3

4

4

5

5

6

7

Содержание IMGC450

Страница 1: ...TION AND OPERATION MANUAL IMGC450 GOOSENECK MICROPHONE BOX CONTAINS 1 x IMGC450 Gooseneck Microphone 1 x Isolated shock mount 3 x Self tapping screws for shock mount installation 1 x Windsock Instruction manual ...

Страница 2: ...1 LISEZ ces instructions 2 Tenez ces instructions 3 Notez tous les avertissements 4 Suivez toutes les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez près aucunes sources de chaleur comme radiateurs regi...

Страница 3: ...EFER SERVICING TO QUALIFIED SERVICE PERSONNEL The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance For European Union countries This symbol on the product or its packaging indicates that this product must not be disposed of with other waste Instea...

Страница 4: ...ker or punch Using a 3 0mm drill pre drill three pilot holes Insert the shock mount into the hole again and fasten down the shock mount with the 3 screws provided Installing IMGC450 into the Shock Mount To install the IMGC450 into the Shock Mount unscrew the bottom plastic screw collar Slide the IMGC450 body into the Shock Mount Re install the bottom plastic screw collar until snug Be careful not ...

Страница 5: ...IMGC450 INSTALLATION AND OPERATION MANUAL 5 DIMENSIONS ...

Страница 6: ...IMGC450 INSTALLATION AND OPERATION MANUAL 6 POLAR PATTERNS AND FREQUENCY RESPONSE TYPICAL FREQUENCY RESPONSE TYPICAL POLAR PATTERNS 250Hz 2000Hz 500Hz 4000Hz 1000Hz 8000Hz ...

Страница 7: ... Oct SENSITIVITY 7 0 mV Pa 42 dBV ELECTRICAL IMPEDANCE 200 Ω MIN LOAD IMPEDANCE 1000 Ω S N RATIO 72dB A weighted MAX SPL 135dB 1 THD PHANTOM POWER V 9 52 V DC CURRENT DRAW 1 9 mA FINISH Matte Black CONNECTION Balanced 3 pin XLR Male Pin 2 Pin 3 Pin 1 shield OPERATING TEMP 10 C 50 C 95 humidity max DIMENSIONS 450 mm Length NET WEIGHT 151g INCLUDED ACCESSORIES Isolation shock mount windsock ...